P83862 M 

 

  Sheet 6 of 23 

 

Figure 2: 

Terminal Locations 

 

DC

BAT

+

-

OPEN = 24V SW1 CLOSED = 12V

AC

AC

AC

+DC

BA

T F

AIL

N

C C

  N

O

 A

C F

AIL

N

C C

  N

O

J1

AC

 T

RO

UB

LE

D

EL

AY

 O

PT

IO

N

OUT1 OUT2 OUT3 OUT4

FAULT

INP1 INP2

1

2

3

4

ON

1

2

3

4

ON

1

2

3

4

ON

1

2

3

4

ON

OUT1

OUT2

OUT3

OUT4

INPUT SELECT

TEMPORAL

STROBE SYNC

IN>OUT SYNC

INPUT SELECT

TEMPORAL

STROBE SYNC

IN>OUT SYNC

AUX

DC

NO "REMOTE" C

AUX

RESET

+

_

+

_

+

_

+

_

+

_

+

_

OUT1

OUT2

OUT3

OUT4

IN1

IN1

IN2

IN2

RET1

RET1

RET2

RET2

+

_

+

_

+

_

+

_

C  "DRY1"  NC

C  "DRY2"  NC

UPPER
LOWER

N

C

C

N

O

"F

AU

LT

" N

C

ON OFF

ON OFF

SW1

SW2

6

1

7

2

5

3

4

8

9

10 11

12

13

14

 

 
 

Содержание POWERPATH PS-12-24-8

Страница 1: ...TER POWER SUPPLY Installation Instructions 273 Branchport Avenue Long Branch NJ 07740 6899 Ph 800 631 2148 Fax 732 222 8707 Web Site www wheelockinc com e mail info wheelockinc com P83862 M Copyright...

Страница 2: ...MOUNTING 7 2 3 WIRING 9 2 4 RELAY STATUS CONNECTIONS 10 3 0 OPERATION 11 3 1 MODES OF OPERATION 11 3 2 DIP SWITCH SETTINGS 11 3 3 CLASS B OPERATION 12 3 4 CLASS A OPERATION 15 3 5 MASTER REMOTE OPERA...

Страница 3: ...power output that can be reset is provided The PS 12 24 8 also contains a battery charger capable of charging either 7 or 12 AMP Hour AH of battery backup The PS 12 24 8 can only provide a maximum loa...

Страница 4: ...hat can be fed to any or all of the output circuits Input and output can be synchronized with IN OUT SYNC mode SM DSM or 2nd PS 12 24 8 is required Audible silence capability Filtered and electronical...

Страница 5: ...YNC IN OUT SYNC AUX DC NO REMOTE C AUX RESET _ _ _ _ _ _ OUT1 OUT2 OUT3 OUT4 IN1 IN1 IN2 IN2 RET1 RET1 RET2 RET2 _ _ _ _ C DRY1 NC C DRY2 NC UPPER LOWER NC C NO C FAULT NC ON OFF ON OFF SW1 SW2 DC BAT...

Страница 6: ...and can be individually programmed for Normal Mode Temporal Mode IN OUT SYNC Mode or WHEELOCK SYNC Mode The outputs can be configured as four Class B circuits two Class A circuits or two Class B and o...

Страница 7: ...T INP1 INP2 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON OUT1 OUT2 OUT3 OUT4 INPUT SELECT TEMPORAL STROBE SYNC IN OUT SYNC INPUT SELECT TEMPORAL STROBE SYNC IN OUT SYNC AUX DC NO REMOTE C AUX RESET _ _...

Страница 8: ...NPACKING The POWERPATH was carefully checked before leaving the factory Inspect shipping container and unit carefully for indications of improper handling If damage is detected make an immediate claim...

Страница 9: ...P83862 M Sheet 8 of 23 Figure 3 Mounting Dimensions BOTTOM FRONT RIGHT TOP VIEW SIDE SIDE LEFT NOTE All dimensions shown are measured in inches...

Страница 10: ...2 Value is determined by FACP F Connect desired auxiliary equipment to the auxiliary output terminals AUX CAUTION For the Ground Fault Detection Circuit to operate the 22K OHM RESISTOR WIRE ASSEMBLY m...

Страница 11: ...n and the C NO will short after 1 minute or 6 hours depending on the condition of J1 J1 in line 1 minute J1 removed 6 hours Refer to Figure 4 LOGIC BOARD COMMON TROUBLE TERMINALS The common trouble te...

Страница 12: ...ut to be utilized by the POWERPATH These appliances may come from a FACP another PS 12 24 8 or a Wheelock Synchronization Module SM 12 24 or DSM 12 24 Audibles can also be silenced WHEELOCK SYNC MODE...

Страница 13: ...PORAL STROBE SYNC IN OUT SYNC OR EOLR 2 2K OHMS LOGIC BOARD SWI OPEN SW2 OPEN TO NEXT APPLIANCE OR EOLR IN1 RET1 OUT1 A P C F TO NEXT APPLIANCE OR EOLR 2 2K OHMS TO NEXT APPLIANCE OUT2 TO NEXT APPLIAN...

Страница 14: ...MODE with a coded input source A second constant input with a second output set in the NORMAL MODE will provide the constant voltage CAUTION Only use audible appliances that can use a coded signal Do...

Страница 15: ...with Wheelock sync appliances Example 6 WHEELOCK SYNC MODE without Audible Silence CLASS B POWERPATH 1 2 3 4 ON OUT1 4 INPUT SELECT TEMPORAL STROBE SYNC IN OUT SYNC LOGIC BOARD SWI OPEN SW2 OPEN IN1...

Страница 16: ...OUT2 and OUT4 When operating in Class A the two circuits must have the same switch settings for the operational mode selected Switches SW1 and SW2 on the logic board are in the CLOSED position IN1 and...

Страница 17: ...or NS NS4 NH appliances with TEMPORAL MODE Example 10 IN OUT SYNC MODE from CODED INPUT SOURCE CLASS A POWERPATH LOGIC BOARD SWI CLOSED SW2 CLOSED 1 2 3 4 O N 1 2 3 4 O N OUT1 OUT3 INPUT SELECT TEMPO...

Страница 18: ...Wheelock external Sync Module SM or DSM synchronization will only occur with Wheelock sync appliances Example 12 IN OUT SYNC MODE with External Sync Module with Audible Silence CLASS A POWERPATH LOGIC...

Страница 19: ...1 4 INPUT SELECT TEMPORAL STROBE SYNC IN OUT SYNC OUT4 OUT2 OUT3 OUT1 RET2 IN2 IN1 AUDIBLE SILENCE RET1 A F P C OR EOLR OR RETURN TO FACP CLASS A TO NEXT APPLIANCE TO NEXT APPLIANCE CLASS A TO FACP OR...

Страница 20: ...OUT SYNC INPUT SELECT TEMPORAL STROBE SYNC IN OUT SYNC AUX DC NO REMOTE C AUX RESET _ _ _ _ _ _ OUT1 OUT2 OUT3 OUT4 IN1 IN1 IN2 IN2 RET1 RET1 RET2 RET2 _ _ _ _ C DRY1 NC C DRY2 NC UPPER LOWER NC C NO...

Страница 21: ...TEMPORAL STROBE SYNC IN OUT SYNC INPUT SELECT TEMPORAL STROBE SYNC IN OUT SYNC AUX DC NO REMOTE C AUX RESET _ _ _ _ _ _ OUT1 OUT2 OUT3 OUT4 IN1 IN1 IN2 IN2 RET1 RET1 RET2 RET2 _ _ _ _ C DRY1 NC C DRY...

Страница 22: ...le C FAULT NC terminals OPEN Check inputs If LED s INP1 or INP2 flashing Check outputs if LED s OUT1 OUT2 OUT3 OUT4 flashing Check circuit connected to C FAULT NC terminals AC LED OFF No AC power inpu...

Страница 23: ...W RSS 24110W RSS 2415C RSS 2430C RSS 2475C RSS 24100C RSS 24MCW APPLIANCES WITH SYNCHRONIZING STROBES MT 24 SLM CH70 24MCW CH70 2415W CH70 241575W CH70 2430W CH70 2475W CH70 24110W CH70 24MCW CH90 241...

Страница 24: ...INING WHETHER A PRODUCT IS SUITABLE FOR THE USER S PURPOSES OR WHETHER IT WILL ACHIEVE THE USER S INTENDED RESULTS THERE IS NO WARRANTY AGAINST DAMAGE RESULTING FROM MISAPPLICATION IMPROPER SPECIFICAT...

Отзывы: