page 9 – 8
D-8000 / Jan 2003
V I R T U A L D I P S W I T C H
Input A Mutes—IN-8 module can be programmed to mute
the control room or studio speakers when the channel is ON.
The D-8000 has three mute control lines. Each of these may
be activated by either an A or B source.
Control Room - mutes the control room when checked
and source A is ON
Studio 1 - mutes studio one when checked and source A
is ON
Studio 2 - mutes studio two when checked and source A
is ON
Input B Mutes
Control Room - mutes the control room when checked
and source B is ON
Studio 1 - mutes studio one when checked and source B
is ON
Studio 2 - mutes studio two when checked and source B
is ON
Input A Tallies—Turning the module ON can activate a
remote tally indicator. There are three tally control lines: "On
Air Tally (1), "Tally2", "Tally3". Remote tallies are hooked-
up to the console at the Control Room (On Air Tally (1)) and
Studio (Tally2, Tally3) modules.
On Air Tally - activates the On-Air Tally control line
when checked and source A is ON
Tally2 - activates the Tally2 control line when checked
and source A is ON
Tally3 - activates the Tally3 control line when checked
and source A is ON
Input B Tallies
On Air Tally - activates the On-Air Tally control line when
checked and source B is ON
Tally2 - activates the Tally2 control line when checked
and source B is ON
Tally3 - activates the Tally3 control line when checked
and source B is ON
Timer Reset—The console's digital timer
can be programmed to automatically reset to
zero and begin counting up when the module's
ON button is pressed. To enable this func-
tion the “AUTO” button on the meter output module has to be
activated. A and B sources are individually configured.
Input Display—You can enter or edit text
to be displayed on the IN-8 module display.
Text boxes for "A" and "B" sources can be
used such that switching from input "A" to
input "B" on the module automatically changes the display.
D-8000 / Aug 2003
Содержание D-8000
Страница 1: ...D 8000 Digital Audio Console TECHNICAL MANUAL 600 Industrial Drive New Bern North Carolina USA 28562...
Страница 134: ...page 16 5 D 8000 Jan 2003 M E T E R B R I D G E page 16 7 D 8000 Nov 2005 Clock Timer Load Sheet CLK 55 Top Bottom...
Страница 148: ...D 8000 Oct 2002 page 17 14...
Страница 149: ...D 8000 Oct 2002 page 17 15...
Страница 152: ...page 17 18 D 8000 Oct 2002...
Страница 153: ...D 8000 Oct 2002 page 17 19...
Страница 154: ...page 17 20 D 8000 Oct 2002...
Страница 155: ...page 17 21 D 8000 Oct 2002...
Страница 156: ...page 17 22 D 8000 Oct 2002...
Страница 157: ...page 17 23 D 8000 Oct 2002...
Страница 158: ...D 8000 Oct 2002 page 17 24...
Страница 161: ...page 17 27 D 8000 Oct 2002...
Страница 165: ...page 17 31 D 8000 Oct 2002...
Страница 166: ...page 17 32 D 8000 Oct 2002...