When using the Water Heater in winter, ensure the flue is not blocked by snow or fallen leaves etc. When not in use,
ensure that the Water Heater is drained. This is particularly important during the winter months as a precaution
against freezing. To drain, switch off the water pump at either the pump switch or main switch. Open all the hot water
taps in the vehicle and operate the drain valve fitted in the system. The drain valve 

must be

left in the “open” position

to ensure all the water drains out.

For installation or serviceable parts advice please contact Whale® Customer Support:

Tel: +44 (0)845 217 2933   Email: [email protected]  

Description of Equipment: 

Gas and Electric Storage Water Heater

Manufacturer’s Declaration

We hereby declare, under our sole responsibility, that the above equipment complies with the provisions of the 
following EC Directives:

Gas Appliance Directive 2009/142/EC on the approximation of the laws of the Member States relating to appliances
burning gaseous fuels. 

Low Voltage Directive 2006/95/EC on the harmonization of the laws of the Member States relating to electrical 
equipment designed for use within certain voltage limits.

Electromagnetic Compatibility Directive 2004/108/EC, on the approximation of the laws of the Member States relating
to electromagnetic compatibility.

CE mark first affixed: June 2009

Basis on which conformity is declared

The above equipment meets the protection requirements of the EMC Directive and the principal elements of the 
safety objectives of the Low Voltage Directive.

Please contact Whale® if further details are required. 

Signed

Richard Bovill
Engineering Director

15

12. EU DECLARATION OF CONFORMITY

10. 

WINTERISING / DRAINING

11. SERVICE SUPPORT DETAILS

Содержание WH1302

Страница 1: ...mensions Plan View Fig 4 Dimensions Front View Fig 5 Installation Locating Diagram Fig 6 Cut Out Hole For Flue Fig 7 Flue Dimensions Fig 8 Reinforce Flue Hole Fig 9 Sealing the Space between Flue and...

Страница 2: ...al Heat Input Gas 1 25kW Standby Consumption Gas 98W Nominal Heat Input Electric 1 2kW Electric 230V a c 50 Hz 600 1200W Maximum Current a c 6 Amps Nominal Voltage 12V d c 10 0V d c min to 15V d c max...

Страница 3: ...vehicle in which the Water Heater is installed in a confined space such as a garage This appliance is not intended for use by persons including children with reduced physical sensory or mental capabi...

Страница 4: ...sure Relief Drain Valve Assembly 1 Male Adaptor Flexible Hose Plumbing Fitting 2 Male Adaptor Flexible Hose Plumbing Fitting 1 Warranty Registration Card 1 Instruction Manual including installation te...

Страница 5: ...ler must check the compatibility of the data plate information with the LPG supply requirements of the vehicle Follow these installation instructions and ensure all relevant personnel read the points...

Страница 6: ...The flue terminal must not be fitted within 300mm of a ventilator for the living space or an opening part of a window Fig 5 Installation Locating Diagram The flue terminal must only be positioned vert...

Страница 7: ...f the flue cover onto the back box and secure with two screws No 6 x 1 2 provided Step 5 Connect Water Heater to Flue Set Water Heater on the floor and slide fully into flue as shown see Fig 12 7 Fig...

Страница 8: ...to the atmosphere at all times Fig 14 Fitting the Pressure Relief Drain Valve Step 7 Secure Water Heater to Floor To secure the Water Heater to the floor use 4 screws No 8 x 1 provided see Fig 15 Fig...

Страница 9: ...wires through the Control Panel mounting frame see Fig 17 and line up the holes with the Control Panel Feed the wires through the cut out in the wall and locate into desired position Secure with 2 scr...

Страница 10: ...es Connect the red flying lead coming from the 8 way connector to a 12V d c supply then connect the white flying lead to the caravan 0V d c Please note Whale recommends that a 5 amp fuse is fitted in...

Страница 11: ...re Relief Valve to prevent back flow of hot water to cold water taps Step 13 Connect Hot Water Supply see Figs 25 26 Screw in the braided hose supplied into the hot water outlet and tighten with a 19m...

Страница 12: ...connected to a suitable 230V a c supply Upon initial operation or to refill after the system has been drained check the drain valve is closed then fill the system with clean fresh water To fill open o...

Страница 13: ...on is illuminated For 1200W press the Water Heater Function key until the high power setting icon is illuminated Note The electric elements will still operate if the appliance is in gas ignition lock...

Страница 14: ...oblem persists contact Whale Support on 44 0 845 217 2933 Option 2 Whale Duo Control Panel In the unlikely event of a failure the red LED on the Control Panel will light see Fig 30 To identify the loc...

Страница 15: ...onsibility that the above equipment complies with the provisions of the following EC Directives Gas Appliance Directive 2009 142 EC on the approximation of the laws of the Member States relating to ap...

Страница 16: ...T19 7TA Tel 44 0 28 9127 0531 Fax 44 0 28 9146 6421 www whalepumps com Email info whalepumps com Copyright Whale 2015 All rights reserved Whale s policy is one of continuous improvement and we reserve...

Отзывы: