1.11a
LED Display:
When not in programming mode the display
shows ‘
- -
’
Water flowing through the flow sensor is
indicated by alternately flashing 'flow rate'
for flow sensor 1 and 'flow rate' for flow
sensor 2. When no water is flowing the
display flashes ‘
- -
’. Flow rate is displayed
in 0.1 litre increments up to 10 ltrs and then
in 1 ltr increments.
1.11b
Flow Rate Display:
When the system is not in status display
mode or configuration mode, it will display
the flow rate on the 7 segment LEDs
With no water flowing the system will
display ‘
- -
’ momentarily every few
seconds
With water flowing the system will display
the following:
Sensor 1 flow rate, Sensor 2 flow rate,
Combined flow rate ... repeating
Flow rates up to 9.9 ltrs/min will be
displayed to 1 decimal place.
Flow rates of 10 ltrs/min and above will
display the rate as the nearest whole
number.
For example:
3.4 ltrs/min on inlet 1
LED show “3.4”
7.5 ltrs/min on inlet 2
LED shows “7.5”
Then total flow is displayed
LED shows “11”
1.11c
Solenoid Switch:
See diagrams 1.13 and 1.14.
Aux 1 is for connection to a momentary
contact switch. When the user closes the
switch Solenoid 1 and Solenoid 2 are
energized for 30 minutes. This allows water
to flow through the shower. If the switch is
closed again the 30 minute timer starts
again.
Technical specification of solenoids.
Voltage:
24V a.c.
Power Draw:
6VA
Pressure Range: 0.2 - 10 bar
Approvals: EN60730-2-8,
WRAC
1.11d
Pump Run Switch:
See diagrams 1.13 and 1.14.
Aux 2 is for connection to a momentary
contact switch. When pressed the pump
runs for 2 minutes and enters the over run
cycle. This may be used where the wet
room is washed down and water needs to
be pumped away.
11
Auxilary Functions
Содержание SDP073R
Страница 9: ...9 Schematic of Dry Deck Components 1 11...
Страница 12: ...12 1 13 1 14...
Страница 20: ...20 Control Unit 755 176 Pump SDS041T...
Страница 21: ...21 Surge Damper 755 228 50mm Gulley 755 140...