Maximum and minimum pipe length
Key
Description
Minimum
Maximum
H1 in
From gully to vertical lift
0.1 m
3 m
V in
Vertical from floor to level of pump
0.15 m
0.5 m
H2 in
Inlet distance from vertical to pump
0.1 m
1 m
H1 out
From outlet to vertical rise
0.2 m
0.4 m
V out
Vertical head
0 m
1 m
H2 out
Horizontal to waste pipe
*See notes below
*If > 1 meter use 1
1
/
4
” or 1
1
/
2
” waste pipe on gravity fall no maximum if on gravity fall
If < 1 m then 22 mm copper may be used to the stack.
1.4
1.4
• Only one vertical lift on the inlet to the
pump and the discharge from the pump
is allowed.
• When laying the pipe under the floor use
only slow radius bends.
• Use slow radius bends above the floor if
possible to ease the flow of water and
reduce loading on the pump.
• Use of copper pipe is recommended to
reduce risk of air leaks at connections.
• Ensure edges are burr-free. Burrs may
cause a build up of hair etc. that will
reduce flow.
• Pipework
must
be secured to prevent
any vibration and noise.
• Twist lock the securing ring on the push
fit fittings (If semi rigid pipe is being used
follow the manufacturers instructions to
prevent air leaks).
5
Plumbing of Waste pipe
1.5
The surge damper prevents water hammer