![Wexxar BEL 507 Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/wexxar/bel-507/bel-507_operation-and-service-manual_966971027.webp)
B E L 5 0 7 X L L
A R G E
C
A S E
T
I L T
P
A C K I N G
S
T A T I O N
1 1
65-15-6 5/11/07
Machine Operating Cycle Description
1.
The edges of the open case bottom major flaps depress the actuators of the two “floor switches”
and the side of the case depresses the wheeled “body switch”. All three switches must be actuated
for the machine cycle to start.
2.
The two small levers of the major (side) flap openers momentarily open the major flaps wider to
clear the minor (end) flaps.
3.
The minor flap folders fold up both end flaps of the box bottom and retract.
Floor Switches
Body Switch
Major Flap Openers
(rotate up to open bottom
major flaps)
Front Minor Flap Folder
Rear Minor Flap Folder
[Tower]