WD-8
Rev. 4.0 (202202)
Technical specifications
52
* option
** Other voltages on request
*** 2 metre-long cable included
* option
** With water colder than 55°C, we recommend a 12kW booster heater
*** At lower pressures, the machine should be supplemented with a break tank
* option
** Including packaging
CONNECTION, MACHINE
Total connected load (kW)
10.5 / 13.5 *
Main fuse 400V 3N~ 50Hz (A) **
16 / 25 *
Max. connection area 400V 3N~ (L1-L3, N, PE) Cu (mm²) ***
2.5
WATER, DRAIN AND VENTILATION CONNECTIONS
Water quality, hardness (°dH)
2–7
Water connection 5-65°C (exterior thread) **
R½"
Drain connection, PP pipe (ø mm)
50
Water capacity, pressure (kPa) ***
180
Water capacity, flow (litres/min.)
18
Water capacity, hood lift, pressure (kPa) *, ***
300
Floor drain, capacity (litres/sec.)
3
Heat load room, latent / sensitive / total (kW)
0.6 / 1.7 / 2.3
SIZE AND WEIGHT FOR TRANSPORT
Size, LxWxH (mm) **
765 x 880 x 1650
Weight (kg) **
135 / 175 *