17
Start Up
Function test
Turn the left controller
TIME
on the motion detector to the left as far as it will
go. Turn the right controller
SENS
to the middle position (arrow is upright).
Cover completely both sides of the solar module to simulate darkness.
To avoid needless energy consumption by passing clouds or other short-time
dimming, the motion detector will only be activated at night and after approx.
10 seconds.
Each time the motion detector activates a self test is carried out. A signal will
be transmitted to the control electronic, which turns on the high-capacity LED.
According to the adjusted time on the controller
TIME
, the motion detector
switches off and turn to back-up mode. The LED turns off.
During any movements in the detection area of the motion detector, the
detector turns the LED on.
You can also switch on the lamps by connecting the terminals
M-
and
MSIG
.
According to the adjusted time, the motion detector switches off the LED.
If you interconnect an external switch, the LED still lights up in the night as
long as the switch is in ON position. Make sure the switch is turned off, if you
test the motion detector.
Operating and Adjustments
Turn
the
controller
TIME
to the desired on-time.
left = short time / right = long time (10 seconds up to 30 minutes).
During parallel operation of several lamps you have to turn the controller
TIME
of all lamps to the same position.
Turn
the
controller
SENS
to the desired sensitivity of the detection sensor.
left = low sensitivity / right = high sensitivity.
If you connect the lamp with the terminals
M-
and
MSIG
and the lamp should
not be activate by the motion detector, turn the middle switch on the motion
detector to the position
OFF
.