![Wetco Water Specialist 1.5EI Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/wetco/water-specialist-1-5ei/water-specialist-1-5ei_programming-and-drawings-manual_966543008.webp)
Page 8
WS 1.5 EI/2LEI Man u al
Diagnostics
Step 1D
Step 2D
Step 3D
Step 4D
Step 5D
EXIT TO
DISPLAY
SCREENS
Step 1D -
Press
▲
and
▼
buttons simultaneously for
5 seconds and release. Then press
▲
and
▼
buttons
simultaneously for 2 seconds and release. If screen
in Step 2D does not appear the lock on the valve is
activated. To unlock press
▼
, NEXT, REGEN,
▲
in
sequence, then press
▲
and
▼
buttons simultaneously
for 5 seconds and release. Then press
▲
and
▼
buttons
simultaneously for 2 seconds and release.
Step 2D -
Display shows the number of days since a
regeneration last occurred. Press NEXT to go to Step
3D. Press REGEN to exit Diagnostics.
Step 3D -
Display shows the volume of water treated
in M
3
treated since the last regeneration. If 7 or 28
was selected in Step 3CS this display will not appear.
If Volume (M
3
), 28/Volume (M
3
), or 7/Volume (M
3
)
was selected in Step 3CS and no meter is installed this
display will read 0. Press NEXT to go to Step 4D. Press
REGEN to return to previous step.
Step 4D -
Display shows the days in service since start
up. Press NEXT to go to Step 5D. Press REGEN to
return to previous step.
Step 5D -
Display shows the total number of
regeneration cycles since start up. Press NEXT to exit
Diagnostics. Press REGEN to return to previous step.