WS 1.5 EI/2LEI Man u al
Page 7
Confi guration Settings
Step 1CS – Press
▲
and
▼
buttons simultaneously for 5 seconds and release. If screen in Step
2CS does not appear, the lock on the valve is activated. To unlock press
▼
, NEXT, REGEN,
▲
in
sequence, then press
▲
and
▼
buttons simultaneously for 5 seconds and release.
Step 2CS – Select 25 for 1” (25 mm), 38 for 1.5” (38 mm) or 50 for 2L (50mm). Press NEXT to go
to Step 3CS. Press REGEN to exit Confi guration Settings.
Step 3CS – Press the
▲
or
▼
buttons to select one of the following:
•
If
Volume
(M
3
) is selected the regeneration will occur after the specifi c volume has been
used or on the day override (if selected) whichever comes fi rst.
• If 28 is selected the regeneration will occur on the day (1 through 28) selected in Installer
Display Settings. The total fl ow and fl ow rate user displays and the volume display in
Diagnostics will not be shown even if a meter is used.
• If 28/Volume (M
3
) is selected the regeneration will occur on the day (1 through 28) selected
in Installer Display Settings. If a meter is not used the total fl ow and fl ow rate user displays
and the volume display in Diagnostics will be shown as 0.
• If 7 is selected the regeneration will occur on the selected day(s) of the week (see
instructions contained in Installer Display Settings). The total fl ow and fl ow rate user
displays and the volume display in Diagnostics will not be shown even if a meter is used.
• If 7/Volume (M
3
) is selected the regeneration will occur on the selected day(s) of the week
(see instructions contained in Installer Display Settings). If a meter is not used the total fl ow
and fl ow rate user displays and the volume display in Diagnostics will be shown as 0.
Press NEXT to go to Step 4CS. Press REGEN to return to previous step.
Step 4CS – Press the
▲
or
▼
buttons to select to regenerate immediately on 0 or at delayed time.
Immediately on 0 can only be selected if Volume (M
3
) was selected in step 3CS and a meter must be
installed. Delay is the only option for the other Step 3CS selections. Press NEXT to go to Step 5CS.
Press REGEN to return to previous step.
Step 5CS –
Allows selection of one of the following:
• an outside signal to initiate a regeneration;
• the Control Valve to act as an alternator; or
• the Control Valve to have no hard water bypass.
Selecting the use of an outside signal to initiate a regeneration: Selection only matters if a
connection is made to the two pin connector labeled DP SWITCH located on the printed circuit
board. Following is an explanation of the options:
dPon0 - If the dP switch is closed for an accumulative time of 2 minutes a regeneration will occur
immediately.
dPdEL - If the dP switch is closed for an accumulative time of 2 minutes a regeneration will occur at
the scheduled regeneration time.
HoLd - If the dP switch is closed a regeneration will be prevented from occurring.
Selecting the Control Valve to act as an alternator:
NOTE:
In step 3CS you must select Volume, Step 4CS select Regeneration Time Option “on 0” and
in Step 3I select Day Override “oFF.”
Select ALTA for the control valve that has the two pin connector labeled DRIVE connected to the
alternator valve motor.
Select ALTb for the control valve that will not be connected to the alternator valve motor.
Confi guring the Control Valve for No Hard Water Bypass Operation: nHbP - Selection requires
that a connection to a Clack Motorized Alternator Valve (MAV) is made to the two pin connector
labeled ALTERNATOR DRIVE located on the printed circuit board. The B port of the MAV must
be plugged and the valve outlet connected to the A port. The MAV will be driven closed before the
fi rst regeneration cycle that is not FILL or SOFTENING or FILTERING, and be driven open after
the last regeneration cycle that is not FILL.
Press NEXT to exit Confi guration Settings. Press REGEN to return to previous step.
Step 1CS
Step 2CS
Step 3CS
Step 4CS
Step 5CS
EXIT TO
DISPLAY
SCREENS