Wet Labs ECO FL Скачать руководство пользователя страница 9

 

ECO 

FL User’s Guide (FL)  

Revision AN 

 

4 June 2012 

 

 

1.3  

Delivered Items 

The standard ECO delivery consists of the following: 

 

the instrument itself 

 

dummy plug with lock collar 

 

protective cover for optics 

 

this user’s guide 

 

ECOView user’s guide 

 

ECOView host program and device files (on CD) 

 

instrument-specific calibration sheet 

 

FL(RT), FL, FLS only: stainless steel mounting bracket and hardware (See Appendix A 
for details) 

 

Internal battery units: six 9-V Lithium batteries (installed) 

Spare Parts 

 

 

Fluorescent stick for bench testing 

 

Bio-wiper

™ units: one 3/32-in. hex key for 

Bio-wiper

™ removal 

 

Bio-wiper

™ units: Three 4-40 x 3/8 in. 316 stainless steel screws for securing 

Bio-wiper

™ 

Additional spare parts for internal battery units 

 

Two end flange O-rings (size 224) and two vent plug O-rings (size 010) 

 

Two jacking screws for connector flange removal 

 

One 3/32-in. hex key for jacking screws 

 

Blue-tipped power plug for autonomous operation 

 

Three pre-cut segments (7 inches) of 0.036-inch diameter monofilament for end flange  

 

Three pre-cut segments (0.25 inches) of 0.094-inch diameter white nylon bar stock 
for replacing the white plastic dowel pin. 

1.4  

Optional Equipment 

1.4.1  Test Cable 

A test cable is optionally available with each unit. This cable includes: 
1.

 

An inline connector for providing power to the instrument from a user-supplied 9V 
battery.  

2.

 

An auxiliary analog out connector. 

3.

 

A DB-9 serial interface connector. 

4.

 

A six-socket connector for providing power and signal to the instrument. 

1.4.2   

Copper Faceplate 

ECO

 meters are optionally equipped with copper faceplates to improve the meter’s 

resistance to biofouling. Refer to Section 3.5.1 for important details on maintenance and 
cleaning.

 

1.4.3   

Bio-wiper

™ and Copper Faceplate 

The FLNTUS and FLNTUSB are equipped with an integrated non-contact anti-fouling 

Bio-

wiper

™ and copper faceplate for use in extended deployments. This wiper can be manually 

controlled by a host controller package, or can perform autonomously as part of a pre-
programmed sampling sequence upon instrument power-up. The rate of closure and 
opening is dependent upon both temperature and depth.  

Содержание ECO FL

Страница 1: ...er s Guide The user s guide is an evolving document If you find sections that are unclear or missing information please let us know Please check our website periodically for updates WET Labs Inc P O B...

Страница 2: ......

Страница 3: ...for servicing or repair that are treated with anti fouling compound s This includes but is not limited to tri butyl tin TBT marine anti fouling paint ablative coatings etc Please ensure any anti foul...

Страница 4: ...ii ECO FL User s Guide FL Revision AN 4 June 2012...

Страница 5: ...ernal Batteries 12 4 1 Removing End Flange and Batteries 12 4 2 Replacing End Flange and Batteries 13 4 3 Checking Vent Plug 14 5 Data Analysis 15 5 1 Scale Factor 15 5 2 Analog Response 15 5 3 Digita...

Страница 6: ......

Страница 7: ...nti fouling bio wiper FLB Provides the capabilities of the FL with internal batteries for autonomous operation FLSB Provides the capabilities of the FLS with internal batteries for autonomous operatio...

Страница 8: ...are shown below Pin Function 1 Ground 2 RS 232 RX 3 Reserved 4 V in 5 RS 232 TX 6 Analog out WARNING If you are going to build or use a non WET Labs built cable do not use the wire from pin 3 or the E...

Страница 9: ...f 0 036 inch diameter monofilament for end flange Three pre cut segments 0 25 inches of 0 094 inch diameter white nylon bar stock for replacing the white plastic dowel pin 1 4 Optional Equipment 1 4 1...

Страница 10: ...mistor output is in counts and can be converted into engineering units using the instrument s device file and ECOView software or the raw data can be converted in the user s software e g MATLAB or Exc...

Страница 11: ...would occur after long exposure to salt water The fitting will generally prevent the oil from escaping from the reservoir into the water However you may occasionally wish to ensure that oil remains i...

Страница 12: ...O uses an LED to provide the excitation source An interference filter is used to reject the small amount of out of band light emitted by the LED The light from the source enters the water volume at an...

Страница 13: ...ration as it can be harmful to the eyes even for brief periods If it is necessary to view a UV LED use suitable UV filtered glasses or goggles to avoid damage to the eyes Keep UV LEDs and products con...

Страница 14: ...r completes the requested samples this is common for meters set up in moored applications it will go into sleep mode and the meter will not light when power is cycled To wake the meter click Stop Data...

Страница 15: ...highly recommend that ECO meters be returned to the factory annually for cleaning calibration and standard maintenance Contact WET Labs or visit our website for details on returning meters and shippi...

Страница 16: ...nt side of the wiper It is normal for copper to corrode and turn green especially after the instrument has been removed from the water This corrosion will slightly reduce the wiper s anti fouling abil...

Страница 17: ...in thick Not enough flex Wiper may not be effective Proper flex Wiper maintains contact with instrument face and optical window Too much flex Wiper may cause too much friction using excessive power 1...

Страница 18: ...c disclaims all product liability from the use or servicing of this equipment WET Labs Inc has no way of controlling the use of this equipment or of choosing qualified personnel to operate it and ther...

Страница 19: ...hen they are secure This will ensure the pack is straight and will fit into the pressure housing with no difficulty 3 Re install the black plastic protective covers on the ends of the screws 4 Remove...

Страница 20: ...ent plug from end flange 2 Pinch bottom O ring around vent plug to form a small gap you can work a toothpick into Use the toothpick to help roll the bottom O ring off the plug 3 Perform the same proce...

Страница 21: ...the concentration of the solution used during instrument characterization Scale Factor 308 ppb meter output counts dark counts For example 308 4148 56 0 0753 The scale factor is then applied to the ou...

Страница 22: ...e Digital data is processed in a similar fashion to analog data Scaling is linear and obtaining a calibrated output simply involves subtracting a digital dark counts value and multiplying the differen...

Страница 23: ...cted to a wet hyperbaric test before final testing The testing chamber applies a water pressure of at least 50 PSI 3 Mechanical Stability Before final testing the ECO FL meters are subjected to a mech...

Страница 24: ...ill make the analog output cover the whole output range 2 will cover half and 1 will cover only the bottom fourth of the 14 bit count range fluorometers only ave single number 1 to 65535 Number of mea...

Страница 25: ...tion The Column Count Specification identifies how many columns of data to expect It follows the format Column n The Column Count Specification must be present before any of the Column Descriptions ar...

Страница 26: ...the FL Setup tab of ECOView The internally calculated fluorescence values engineering scale offset and output can also be set from the FL Setup tab Engineering units are displayed through ECOView wher...

Страница 27: ...on wavelength of the chlorophyll signal is displayed 8 5 1 Firmware Versions 3 01 and Higher Below is a sample output file for an ECO chlorophyll fluorometer equipped with an optional external thermis...

Страница 28: ...6 14 2008 7 57 57 5201 75 540 6 14 2008 7 57 58 5202 74 540 6 14 2008 7 57 59 5203 74 540 6 14 2008 7 58 00 5203 75 540 Sample output file with processed data in g l no external thermistor Date MM DD...

Страница 29: ...ortunity to work with our customers and the EU to reduce the environmental impact resulting from the continuous improvement of our products WEEE Return Process To meet the requirements of the WEEE Dir...

Страница 30: ...s to Lithium batteries for applicable models DCR 433 I Walsh U 7 26 05 Replace Clean Water Offset with Dark Counts DCR 468 M Johnson V 12 7 05 Clarify Section 5 fluorescent stick description separate...

Отзывы: