Wet Labs ECO FL Скачать руководство пользователя страница 3

 

ECO 

FL User’s Guide (FL)  

Revision AN 

 

4 June 2012 

 

 

ECO

 Sensor Warranty 

This unit is guaranteed against defects in materials and workmanship for one year from the 
original date of purchase. Warranty is void if the factory determines the unit was subjected to 
abuse or neglect beyond the normal wear and tear of field deployment, or in the event the 
pressure housing has been opened by the customer.  
 
To return the instrument, contact WET Labs for a Return Merchandise Authorization (RMA) and 
ship in the original container. WET Labs is not responsible for damage to instruments during the 
return shipment to the factory. WET Labs will supply all replacement parts and labor and pay for 
return via 3

rd

 day air shipping in honoring this warranty.

 

 
 

Return Policy for Instruments with  

Anti-fouling Treatment 

WET Labs cannot accept instruments for servicing or repair that are treated with anti-fouling 
compound(s). This includes but is not limited to tri-butyl tin (TBT), marine anti-fouling paint, 
ablative coatings, etc.  

 

Please ensure any anti-fouling treatment has been removed prior to returning instruments to 
WET Labs for service or repair. 

 

 

Shipping Requirements 

1.  Please retain the original ruggedized shipping case. It meets stringent shipping and 

insurance requirements, and protects your meter. 
 

2.  Service and repair work cannot be guaranteed unless the meter is shipped in its original 

case. 
 

3.  Clearly mark the RMA number on the outside of your case and on all packing lists. 
 
4.  Return instruments using 3

rd

 day air shipping or better: do 

not

 ship via ground.  

 

 
 

 

Electrical equipment marked with this symbol may not be disposed 
of in European public disposal systems. In conformity with EU 
Directive 2002/96/EC (as amended by 2003/108/EC), European 
users of electrical equipment must return old or end-of-life 
equipment to the manufacturer for disposal at no charge to the user. 

 

 

Содержание ECO FL

Страница 1: ...er s Guide The user s guide is an evolving document If you find sections that are unclear or missing information please let us know Please check our website periodically for updates WET Labs Inc P O B...

Страница 2: ......

Страница 3: ...for servicing or repair that are treated with anti fouling compound s This includes but is not limited to tri butyl tin TBT marine anti fouling paint ablative coatings etc Please ensure any anti foul...

Страница 4: ...ii ECO FL User s Guide FL Revision AN 4 June 2012...

Страница 5: ...ernal Batteries 12 4 1 Removing End Flange and Batteries 12 4 2 Replacing End Flange and Batteries 13 4 3 Checking Vent Plug 14 5 Data Analysis 15 5 1 Scale Factor 15 5 2 Analog Response 15 5 3 Digita...

Страница 6: ......

Страница 7: ...nti fouling bio wiper FLB Provides the capabilities of the FL with internal batteries for autonomous operation FLSB Provides the capabilities of the FLS with internal batteries for autonomous operatio...

Страница 8: ...are shown below Pin Function 1 Ground 2 RS 232 RX 3 Reserved 4 V in 5 RS 232 TX 6 Analog out WARNING If you are going to build or use a non WET Labs built cable do not use the wire from pin 3 or the E...

Страница 9: ...f 0 036 inch diameter monofilament for end flange Three pre cut segments 0 25 inches of 0 094 inch diameter white nylon bar stock for replacing the white plastic dowel pin 1 4 Optional Equipment 1 4 1...

Страница 10: ...mistor output is in counts and can be converted into engineering units using the instrument s device file and ECOView software or the raw data can be converted in the user s software e g MATLAB or Exc...

Страница 11: ...would occur after long exposure to salt water The fitting will generally prevent the oil from escaping from the reservoir into the water However you may occasionally wish to ensure that oil remains i...

Страница 12: ...O uses an LED to provide the excitation source An interference filter is used to reject the small amount of out of band light emitted by the LED The light from the source enters the water volume at an...

Страница 13: ...ration as it can be harmful to the eyes even for brief periods If it is necessary to view a UV LED use suitable UV filtered glasses or goggles to avoid damage to the eyes Keep UV LEDs and products con...

Страница 14: ...r completes the requested samples this is common for meters set up in moored applications it will go into sleep mode and the meter will not light when power is cycled To wake the meter click Stop Data...

Страница 15: ...highly recommend that ECO meters be returned to the factory annually for cleaning calibration and standard maintenance Contact WET Labs or visit our website for details on returning meters and shippi...

Страница 16: ...nt side of the wiper It is normal for copper to corrode and turn green especially after the instrument has been removed from the water This corrosion will slightly reduce the wiper s anti fouling abil...

Страница 17: ...in thick Not enough flex Wiper may not be effective Proper flex Wiper maintains contact with instrument face and optical window Too much flex Wiper may cause too much friction using excessive power 1...

Страница 18: ...c disclaims all product liability from the use or servicing of this equipment WET Labs Inc has no way of controlling the use of this equipment or of choosing qualified personnel to operate it and ther...

Страница 19: ...hen they are secure This will ensure the pack is straight and will fit into the pressure housing with no difficulty 3 Re install the black plastic protective covers on the ends of the screws 4 Remove...

Страница 20: ...ent plug from end flange 2 Pinch bottom O ring around vent plug to form a small gap you can work a toothpick into Use the toothpick to help roll the bottom O ring off the plug 3 Perform the same proce...

Страница 21: ...the concentration of the solution used during instrument characterization Scale Factor 308 ppb meter output counts dark counts For example 308 4148 56 0 0753 The scale factor is then applied to the ou...

Страница 22: ...e Digital data is processed in a similar fashion to analog data Scaling is linear and obtaining a calibrated output simply involves subtracting a digital dark counts value and multiplying the differen...

Страница 23: ...cted to a wet hyperbaric test before final testing The testing chamber applies a water pressure of at least 50 PSI 3 Mechanical Stability Before final testing the ECO FL meters are subjected to a mech...

Страница 24: ...ill make the analog output cover the whole output range 2 will cover half and 1 will cover only the bottom fourth of the 14 bit count range fluorometers only ave single number 1 to 65535 Number of mea...

Страница 25: ...tion The Column Count Specification identifies how many columns of data to expect It follows the format Column n The Column Count Specification must be present before any of the Column Descriptions ar...

Страница 26: ...the FL Setup tab of ECOView The internally calculated fluorescence values engineering scale offset and output can also be set from the FL Setup tab Engineering units are displayed through ECOView wher...

Страница 27: ...on wavelength of the chlorophyll signal is displayed 8 5 1 Firmware Versions 3 01 and Higher Below is a sample output file for an ECO chlorophyll fluorometer equipped with an optional external thermis...

Страница 28: ...6 14 2008 7 57 57 5201 75 540 6 14 2008 7 57 58 5202 74 540 6 14 2008 7 57 59 5203 74 540 6 14 2008 7 58 00 5203 75 540 Sample output file with processed data in g l no external thermistor Date MM DD...

Страница 29: ...ortunity to work with our customers and the EU to reduce the environmental impact resulting from the continuous improvement of our products WEEE Return Process To meet the requirements of the WEEE Dir...

Страница 30: ...s to Lithium batteries for applicable models DCR 433 I Walsh U 7 26 05 Replace Clean Water Offset with Dark Counts DCR 468 M Johnson V 12 7 05 Clarify Section 5 fluorescent stick description separate...