background image

your room is that cooler or that the heater is not heating. If your heater’s display and your external 
temperature read-out mechanism (thermometer, wall thermostat, etc.) are within a 5 to 6 degree 
difference, it is completely normal. 

 
 
 
 
 

 

Recommendations for Maximum Performance 

1.  Be sure not to place the heater in an area where the air flow or air movement is great.   

2.  Direct the outflow towards the center of the room and not against a solid structure, like a wall for 

example.  For larger areas, place the heater within a central location. 

3.  The Infrared Heater designed for maximum efficiency in the 68

F to 74

0

 F range.  This is because 

of the ambient air moving through the heater and out constantly. 

4.  Existing HVAC heating system vents should be closed.  This allows the heater to function in an 

isolated area. 

5.  It is not recommended to operate heater in areas exposed to non-insulated concrete or metal 

walls.  Concrete floors should be covered to insulate the heat within the room. 

6.   If the heater filters become dirty or dusty, they must be cleaned for the heater to operate at its 

maximum efficiently. 

Care, Maintenance, and Storage

 

Before care or maintenance is applied, always unplug the cord from the receptacle.    The cabinet 
housing can be wiped down with water and a damp cloth or with furniture polish.  The heater has a 
washable filter.  The filter should be cleaned regularly to provide for maximum performance.  Once the 
filter is removed, run warm water through and over the filter to remove dirt and dust.  Shake all water 
residue from the filter and replace it back in the heater.  (Note: A mild soap can be applied to assist in 
removing dirt and dust from the filter) 
 
If the heater is not to be used for an extended period of time, it can be stored away.  Make sure the 
power is turned off and the cord is unplugged from the receptacle.  Wrap the cord around the handle on 
the rear of the portable heater.  Cover the heater to prevent dust from accumulating on the heater.  You 
may want to repack it back in its original carton.  Always store the heater in a dry and dust free 
environment.   
 
(Note: You may want to clean the filter prior to storing the heater away so that it is ready for operation the 
next time it is put in use.) 

 

 

Содержание WI-0035

Страница 1: ...RCUIT The Infrared Heater works with your in home furnace to provide supplement heat Carefully and thoroughly read this manual before using the Infrared Heater for the first time We recommend keeping this manual for regular review and future reference Heater is intended for residential use 1 ...

Страница 2: ... following safety instructions The heater must be operated by an adult Keep heater out of the reach of children Only operate the heater when it is on the floor Do not operate heater near any water Do not plug heater into any other cord connected device such as power strip surge protector multiple outlet adapter grounding adapter outlet type air fresheners or extension cords Plug the heater cord di...

Страница 3: ...nous Copper Plate HI Function 1500 watts Heating Elements 4 Infrared Quartz Bulbs LOW Function 750 watts Power Requirement 120V 15 amp Electrostatic Washable Filter Heating Elements Life Expectancy Potential Rated 20 000 hrs Warranty Limited 3 Year Parts Only Heat Type Therapeutic Quartz Infrared Heat How It Works The Infrared Heater works with your in home furnace to provide supplement heat In sh...

Страница 4: ...ceful material in reflecting the infrared rays E The LED Digital Display is a convenient stylish and modern way to display the set temperature and time This attractive addition compliments the Infrared Heater in that it simplifies and makes controlling the unit easy Operating the heater is logical and can be done on the unit itself or by remote Unpacking the Infrared Heater 1 First check the carto...

Страница 5: ...l switch from the temperature status to the TIME status and begin to flash The default time will display This means that the TIME is not activated and therefore the heater will remain on You must press the HI LOW UP button or the 0 C 0 F DOWN once again within 5 seconds to set the time Each time you press the HI LOW UP button the time will increase by 0 5 Hr If you press the 0 C 0 F DOWN button th...

Страница 6: ...6 The Infrared Heater can be turned off by pressing the POWER button DO NOT TURN OFF THE MASTER POWER SWITCH ON THE REAR OF THE HEATER OR UNPLUG THE HEATER UNTIL THE FAN SHUTS DOWN If the heater is left on using the TIME function there will be 5 second sound alert to let you know that the time is expiring If no actions are taken the heater will shut off 7 Note that the temperature displayed on the...

Страница 7: ...e dirty or dusty they must be cleaned for the heater to operate at its maximum efficiently Care Maintenance and Storage Before care or maintenance is applied always unplug the cord from the receptacle The cabinet housing can be wiped down with water and a damp cloth or with furniture polish The heater has a washable filter The filter should be cleaned regularly to provide for maximum performance O...

Страница 8: ...contact the manufacturer immediately for further troubleshooting 4 PROBLEM a The portable heater continues to operate even when the power switch is turned off SOLUTION Do not unplug The portable heater has a fan that will continue to operate even when the power switch is turned off This fan continues to run in order to cool down the portable heater Once the fan stops running you can then unplug th...

Страница 9: ...cases a When warranty period has expired b Force majeure c Rough and wrong operation on the Portable Heater 4 The warranty extends only to the manufacturing defects and does not cover any damage resulting from mishandling of the product by the owner Certificate of Warranty This product has completely passed tests on quality control and safety features conducted by the technical department of the M...

Отзывы: