background image

 

9000P

 

Wireless

 

Alarm

 

Owner’s

 

Manual

 

 

Page 13 

Company

 

Information

 

 

WestOz

 

Wireless

 

Inc.

 

15272

 

Stony

 

Creek

 

Way,

 

Suite

 

A

 

Noblesville,

 

IN.

  

46060

 

Authorized

 

Distributor

 

for

 

Dynamco

 

Pty

 

Ltd.

 

 

Email

 

Us:

 

[email protected]

 

 

Web

 

Sites

 

and

 

affiliates:

 

www.westozwireless.com

 

www.toolguard.com

  

www.rv

guard.com

  

 

Sales,

 

Marketing

 

and

 

Distribution

 

Inquiries

 

USA:

 

877

737

9937

 

Toll

 

Free

 

 

Product

 

Installation

 

and

 

Technical

 

Support

 

USA:

 

877

737

9937

 

Toll

 

Free

 

 

Quality

 

Manufacturing

 

Certifications:

 

ISO9001:2000

 

and

 

TS16949

  

 

FCC

 

Statement

 

This

 

equipment

 

has

 

been

 

tested

 

and

 

found

 

to

 

comply

 

with

 

the

 

limits

 

for

 

a

 

Class

 

B

 

digital

 

device,

 

pursuant

 

to

 

part

 

15

 

of

 

the

 

FCC

 

rules.

 

You

 

are

 

cautioned

 

that

 

changes

 

or

 

modifications

 

not

 

expressly

 

approved

 

by

 

the

 

part

 

responsible

 

for

 

compliance

 

could

 

void

 

the

 

user’s

 

authority

 

to

 

operate

 

the

 

equipment.

 

This

 

equipment

 

has

 

been

 

tested

 

and

 

found

 

to

 

comply

 

with

 

the

 

limits

 

for

 

a

 

Class

 

B

 

digital

 

device,

 

pursuant

 

to

 

part

 

15

 

of

 

the

 

FCC

 

rules.

 

These

 

limits

 

are

 

designed

 

to

 

provide

 

reasonable

 

protection

 

against

 

harmful

 

interference

 

in

 

a

 

residential

 

installation.

 

This

 

equipment

 

generates

 

uses

 

and

 

can

 

radiate

 

radio

 

frequency

 

energy

 

and,

 

if

 

not

 

installed

 

and

 

used

 

in

 

accordance

 

with

 

the

 

instructions,

 

may

 

cause

 

harmful

 

interference

 

to

 

radio

 

communications.

 

However,

 

there

 

is

 

no

 

guarantee

 

that

 

interference

 

will

 

not

 

occur

 

in

 

a

 

particular

 

installation.

 

If

 

this

 

equipment

 

does

 

cause

 

harmful

 

interference

 

to

 

radio

 

or

 

television

 

reception,

 

which

 

can

 

be

 

determined

 

by

 

turning

 

the

 

equipment

 

off

 

and

 

on,

 

the

 

user

 

is

 

encouraged

 

to

 

try

 

to

 

correct

 

the

 

interference

 

by

 

one

 

or

 

more

 

of

 

the

 

following

 

measures:

 

Reorient

 

or

 

relocate

 

the

 

receiving

 

antenna.

 

Increase

 

the

 

separation

 

between

 

the

 

equipment

 

and

 

receiver.

 

Connect

 

the

 

equipment

 

into

 

an

 

outlet

 

on

 

a

 

circuit

 

different

 

from

 

that

 

to

 

which

 

the

 

receiver

 

is

 

connected.

 

Consult

 

the

 

dealer

 

or

 

an

 

experienced

 

radio/TV

 

technician

 

for

 

help.

 

This

 

device

 

complies

 

with

 

Part

 

15

 

of

 

the

 

FCC

 

Rules.

 

Operation

 

is

 

subject

 

to

 

the

 

following

 

two

 

conditions:

 

1)

 

This

 

device

 

may

 

not

 

cause

 

harmful

 

interference

 

and

 

2)

 

This

 

device

 

must

 

accept

 

any

 

interference

 

received,

 

including

 

interference

 

that

 

may

 

cause

 

undesired

 

operation

 

of

 

the

 

device.

 

 

Содержание 9000P

Страница 1: ...9000P Wireless Alarm Owner s Manual ...

Страница 2: ...Alarm 4 Panic Mode 5 Diagnostics 5 What triggered my Alarm 5 Low Battery Warning 6 Low Battery Detection for a specific sensor 6 Pairing Sensors 8 Putting Alarm Siren into Pair Mode 8 Pairing a new PIN Pad 9 Pairing a new Key Fob 9 Pairing a DoorGuard Sensor 10 Pairing a PIR Motion Sensor 10 Changing your PIN on the PIN Pad 11 Special Functions 12 PIN Pad Functions 12 Key Fob Functions 12 ...

Страница 3: ...our valuable contents This manual describes the key features and functions of your system and how to operate these System Functionality Arming your Alarm The 9000P has 2 options for arming as outlined below Actual arming is done via either your PinPad or your Key FOB Arm Home When arming in home mode the PIR motion sensors will become inactive This will give you the ability to move around the room...

Страница 4: ...second giving you time to disarm the alarm before the siren sounds This pre trigger warning sounds like 3 rapid chirps a delay 3 rapid chirps a delay and then 3 final rapid chirps During this pre trigger warning the system must be deactivated disarmed by either the Pin Pad or the Remote Key Fob otherwise the siren will sound Once triggered the siren will sound for 30 seconds and will then rearm Fo...

Страница 5: ...ive some extra chirps to provide you with additional information about the condition of the Alarm and sensors as well as information about why the Alarm went off These are described below What triggered my Alarm In the event the system was triggered in your absence when disarming the Alarm you will hear a beep followed by a melody You can then go into diagnostic mode to determine which sensor was ...

Страница 6: ...stalled for example 2 PIR movement sensors then it may be useful to find out which actual sensor caused a particular trigger Low Battery Warning General When arming or disarming the system if a low battery condition is detected in either the Alarm Siren or any of the wireless sensors the Siren will emit two extra low frequency beeps If the Siren module itself has a low battery there will be a brie...

Страница 7: ...ensor 3 Open each door or compartment that contains a movement sensor You will hear a single beep from the Alarm Siren if the batteries are in good condition Once you locate a sensor with a low battery it will send a signal and you will hear a melody playing there is no visual indicator for door sensors Replace batteries in that sensor and continue to the next sensor and so on 4 Once you have test...

Страница 8: ...place the Alarm Siren into pair mode Method A button inside the Alarm Siren Install the three AA batteries into the main Alarm Siren unit Press and release the black program button located on the circuit board next to the battery compartment The unit will beep twice green LED flashes slowly searching for a signal for the next 60 seconds If any of the LED indicator s flash Red rapidly the pairing a...

Страница 9: ...ing process again Pairing a new PIN Pad First place the Siren into pairing mode using one of the methods A C described above Once the Alarm Siren is in pair mode hold down the button for 3 seconds Wait until the red lights turns on then flashes rapidly and finally until they stop flashing Enter 1 4 The red lights will flash rapidly on the PIN Pad and the green light on the Alarm Siren will flash r...

Страница 10: ... mode press the program button on the DoorGuard circuit board using something like a ballpoint pen The green LED on the DoorGuard circuit board will illuminate and flash slowly as it searches and then rapidly when pairing has been accepted and then goes out Repeat this procedure for each additional sensor s added to the system Note The Red LED on sensor circuit board will flash rapidly upon failur...

Страница 11: ...PIN Pad press the button and hold for 3 seconds First a single red light will turn on and then two red lights begin to flash rapidly Wait until the lights stop flashing Enter the change PIN sequence 1 2 3 Three red lights will flash and the PIN Pad will beep Within three seconds enter the old PIN then Lights will flash and the PIN Pad will beep The red light between numbers 1 4 will stay on Now en...

Страница 12: ... Hold both top and bottom buttons down simultaneously for 3 seconds The red and green lights will flash on the top button Wait until the lights stop flashing Press the top button as many times as the function indicates see chart below Each time you press the top button it will illuminate green Then press the bottom button to send the function The green light flashes rapidly on the Alarm Siren unit...

Страница 13: ... to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does ca...

Отзывы: