FPAC2 UPgrAde

InstallatIon and operatIon manual

TAble 3 - dIFFereNCes beTweeN dO blOCk ChANNels

dO.ChANNel - discrete Output Channels correspondence
FPAC1 rev 2,3,4

FPAC2 rev 5

Notes

0

No Transducer Connection

0

No Transducer Connection

No change

1

Open/Close

1

TRD1: 0-Close / 1-Open

Same channel number and same functionality for valve 1

2

Open

2

TRD1: 0-Not Open / 1-Open

Same channel number and same functionality for valve 1

3

Close

3

TRD1: 0-Not Close / 1-Close

Same channel number and same functionality for valve 1

4

Stop

4

TRD1: 0-Not Stop / 1-Stop

Same channel number and same functionality for valve 1

5

Open/Close/Stop

5

TRD1: 0-Close / 1-Open / 2-Stop

Same channel number and same functionality for valve 1

6

Open/Close for second valve (when available)

21

TRD2: 0-Close / 1-Open

Channel number has changed. Same functionality for valve 2

7

Open for second valve (when available)

22

TRD2: 0-Not Open / 1-Open

Channel number has changed. Same functionality for valve 2

8

Close for second valve

23

TRD2: 0-Not Close / 1-Close

Channel number has changed. Same functionality for valve 2

-

-

24

TRD2: 0-Not Stop / 1-Stop

New channel functionality for valve 2

-

-

25

TRD2: 0-Close / 1-Open / 2-Stop

New channel functionality for valve 2

-

-

91

FSTATE - TRD 1 (Valve 1)

New channel to force fault state on transducer 1

-

-

92

FSTATE - TRD2 (Valve 2)

New channel to force fault state on transducer 2

8.3 discrete Output (dO) Channels

For a complete description of the channels refer to IOMs TECH-485 and VCIOM-05123

FF, Fieldbus Foundation, Foundation Fieldbus, FieldComm group and the related trademarks and 
logos are property of the FieldComm group ©2017 FieldComm group

Delta V, Emerson and the related trademarks and logos are property of Emerson Electric Co. 
©2017

The Westlock and related trademarks are owned by Crane Co. All other marks are the property of 
their respective owners.

The contents of this publication are presented for informational purposes only, and while every 
effort has been made to ensure their accuracy, they are not to be construed as warranties or 
guarantees, express or implied, regarding the products or services described herein or their use 
or applicability. Westlock reserves the right to modify or improve the designs or specifications of 
such products at any time without notice.

Westlock does not assume responsibility for the selection, use and maintenance of any product. 
Responsibility for the selection, use and maintenance of any product remains with the purchaser 
and end-user.

Содержание FPAC1

Страница 1: ...one rotary valve using the internal Hall Effect sensors as limit switches The application controls the valve position through 1 one DO block and gets the position feedback from 1 one DI block Other c...

Страница 2: ...rade Installation and operation manual Fieldbus input polarity insensitive Fieldbus input J2 J5 analog pos pot Earth ground Embedded hall effect sensors Top opened limit SW Bottom closed limit SW Top...

Страница 3: ...cable shield The cable s shield should be cut short and taped to avoid strains contact with any metallic surface or other wires See Figure 4 Step 3 Install the new electronic module in the housing Ma...

Страница 4: ...t listed contact Westlock to receive the latest DD CF files 0501 or download it directly from the Fieldbus Foundation registered products website link below 2 See Figure 7 Note 2 This URL is maintaine...

Страница 5: ...in the Decommissioned Fieldbus Devices list check if it is available for commissioning If not right click on it and select Place in Standby Wait until this process is finished and the window closes S...

Страница 6: ...inished right click on it and select Properties change device revision to 5 and click on OK See Figure 10 Step 11 If a warning message appears indicating some incompatibilities click OK Right click on...

Страница 7: ...Step 12 Selected the new device from the list and click OK If a warning message appears click OK In the window that will appear DO NOT click Reconcile Device just click Next See Figure 12 Step 13 Clic...

Страница 8: ...on Right click on the device and select Configure Setup The AMS window will open See Figure 14 Figure 14 Figure 15 Figure 16 Step 15 In the menu tree select Transducer Basic Setup Reconfigure the new...

Страница 9: ...n the persistent database Use DeltaV explorer or Control Studio for function blocks configuration as illustrated in the next section Figure 17 Figure 18 6 Reassigning the function blocks in the existe...

Страница 10: ...the DO and DI blocks Sometimes this step is automatically done by the system depending on the system s configuration See Figure 20 Figure 19 Figure 20 Figure 21 Step 22 After unassigning all function...

Страница 11: ...message appears click Yes OK and wait until the download is finished successfully See Figure 23 Figure 22 Figure 24 Figure 23 Step 27 Close the download window and open the Control Studio in online m...

Страница 12: ...mal Acting ACTION_ELEMENT 1 Single Action IO_ASSIGNMENT 1 Top Bot Out0 SIGNAL_ACTION 1 Increase to Close ACTION_ELEMENT 1 Single Action IO_ASSIGNMENT 6 Aux1 Aux2 Out1 SIGNAL_ACTION 0 Increase to Open...

Страница 13: ...ew channel functionality for valve 2 25 TRD2 0 Close 1 Open 2 Stop New channel functionality for valve 2 91 FSTATE TRD 1 Valve 1 New channel to force fault state on transducer 1 92 FSTATE TRD2 Valve 2...

Страница 14: ...relevant notified certification body and therefore the original English document will prevail No rights or liability can be derived from any translation Previous documents VCIOM 05124 EN replaces all...

Отзывы: