TROUBLESHOOTING GUIDE

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some cases, these

installation errors may be mistaken for defects. If you experience any faults, please check this Trouble Shooting Chart. If a problem cannot

be remedied, please consult with your authorized electrician and do not attempt any electrical repairs yourself.

TROUBLE 

1. If fan does not start:

2. If fan sounds noisy: 

3. If fan wobbles:

SUGGESTED REMEDY

1. Check main and branch circuit fuses or circuit breakers.
2. Check wire connections as performed in step #15 or #16 of installation. 

CAUTION:

Make sure main power is turned off.

3. Make sure slide switch is pushed firmly to one side or the other. The fan will not operate with the slide switch in the middle.
4. If the fan still will not start, contact a qualified electrician. Do not attempt to troubleshoot internal electrical connections yourself.

1. Check to make sure all screws in motor housing are snug (not over tightened).
2. Check to make sure the screws which attach the fan blade holder to the motor are tight.
3. If using an optional Ceiling Fan Light Kit, check to be sure the screws securing the glassware are finger tight. Check to be sure light bulb is tight in socket and not 

touching glass shade(s). If vibration persists from glass, remove glass and install a 6mm wide rubber band on glass neck to act as an insulator. Replace glass and 
tighten screws against rubber band.

4. Some fan motors are sensitive to signals from Solid State variable speed controls. DO NOT USE a Solid State variable speed control.
5. Allow “break-in” period of 24 hours. Most noises associated with a new fan will disappear after this period.

All blades are weighed and grouped by weight. Natural woods vary in density which could cause the fan to wobble even though all blades are weight-matched.
The following procedures should eliminate most of the wobble. Check for wobble after each step.

1. Check that all blades are screwed firmly into blade holders.
2. Check that all blade holders are tightened securely to motor.
3. Make sure that canopy and mounting bracket are tightened securely to ceiling joist.
4. Most fan wobble problems are caused when blade levels are unequal. Check this level by selecting a point on the ceiling above the tip of one of the 

blades.Measure this distance as shown in Figure 1. Keeping measure within 3mm, rotate the fan until the next blade is positioned for measurement. 
Repeat for each blade. If all blade levels are not equal, you can adjust blade levels by the following procedure. To adjust a blade tip down, insert a 
washer (not supplied) between the blade and blade holder at the screw closest to the motor (Figure 2). To adjust a blade tip up, insert washer (not 
supplied) between the blade and blade holder at the two screws farthest from the motor (Figure 2).

5. If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistribute the weight and possibly result in smoother operation.

Figure 1

Figure 2

Touching

Ceiling

Blade Tip Down:

Fan Blade

Blade Tip Up:

Fan Blade

Blade Brackets

UL_Xavier_72265  12/13/05  9:18 AM  Page 22

Содержание Xavier-WH05

Страница 1: ...NUAL MANUAL DEL USUARIO XavierTM Please write model number here for future reference Por favor incluya el n mero del modelo aqu para futura referencia Net Weight 17 18 LBS Peso Neto 7 81 KGS UL_Xavier...

Страница 2: ...g or during cleaning Do not insert foreign object between rotating blades 10 Attach the mounting bracket using only the hardware supplied with the outlet box Fan is only to be mounted to an outlet box...

Страница 3: ...s lo la torniller a suministrada con la caja de embutir El ventilador s lo se debe montar en una caja de embutir marcada Acceptable for Fan Support Aceptable para soportar ventiladores 11 Para reduci...

Страница 4: ...asos bajos COMBO BLADE Combo Blades feature two high quality finishes on one blade Select the one that best complements your decor or change the style with just a flip of the blade NOTE Combo Blade fi...

Страница 5: ...NG FOR INSTALLATION ANTES DE LA INSTALACI N Quite el envoltorio e inspeccione detenidamente el ventilador para verificar que todas las piezas est n incluidas Apague la alimentaci n en la caja de fusib...

Страница 6: ...ot remove the screws in the mating slots 2 on the canopy Rotate the mounting bracket and remove from the canopy Quite los tornillos y las dos arandelas en estrella de los dos orificios coincidentes 1...

Страница 7: ...N VARILLA VERTICAL PARA CIELORRASO NORMAL Si instala la varilla vertical incluida con el ventilador proceda a la p gina 9 paso 9 EXTENDED DOWNROD OPTION Ifinstallingwithlongerdownrodthansuppliedwithfa...

Страница 8: ...base del dosel como se indica Fije el dosel al alojamiento del motor con los tres tornillos de montaje al ras y las arandelas de presi n que extrajo previamente Apriete los tornillos asegur ndolos 6...

Страница 9: ...od Insert keeper pin 2 into cross pin until it snaps into place Tighten set screws 3 in coupling Slide coupling cover 4 over the downrod coupling PROCEED TO PAGE 11 STEP 14 Inserte la varilla vertical...

Страница 10: ...2 by removing set screw 3 Afloje la esfera de la varilla vertical 1 de la varilla vertical 2 quitando el tornillo 3 2 1 2 1 Slide downrod ball 1 off of downrod and remove pin 2 Deslice la esfera de l...

Страница 11: ...wnrods have a pre drilled set screw hole If a pre drilled hole is present in the extended downrod tighten the set screw into the pre drilled hole in the extended downrod If no pre drilled hole exists...

Страница 12: ...n Negro vivo Azul vivo Principal tierra Blanco com n Interruptor del ventilador vivo Interruptor de la luz vivo Verde de tierra Del Ventilador De La Casa conectar conectar conectar conectar Conecte el...

Страница 13: ...ve el dosel permitiendo que los dos tornillos se deslicen dentro de las ranuras Gire el dosel hasta que ambos tornillos del soporte de montaje caigan dentro de las ranuras Apriete los tornillos asegur...

Страница 14: ...ish from the surface of the canopy Para instalar el anillo de la cubierta del dosel quite la parte posterior de las tiras de cinta adhesiva en el interior del anillo de la cubierta Deslice el anillo d...

Страница 15: ...rovided Tighten screws securely Fije el conjunto de las paletas al motor usando los tornillos para el motor incluidos Apriete los tornillos asegur ndolos Check the motor for plastic shipping stabilize...

Страница 16: ...s cables del motor a trav s del orificio del alojamiento del interruptor y use el conector molex de 9 pines para conectar los cables del alojamiento del interruptor a los cables del motor 23 22 Remove...

Страница 17: ...iento del interruptor 1 a la placa correspondiente 2 colocando las ranuras bocallaves del alojamiento 3 sobre las dos cabezas de los tornillos que sobresalen en la placa del alojamiento 4 Gire el aloj...

Страница 18: ...l artefacto luminoso y del motor y desl celos para unirlos Conecte el cable azul del alojamiento del interruptor al cable negro del artefacto luminoso y el cable blanco del alojamiento del interruptor...

Страница 19: ...las piezas finales correspondientes a las cadenas del ventilador introduciendo el extremo de la cadena larga en la pieza de uni n Aseg rese de que las cadenas est n bien sujetas tirando ligeramente de...

Страница 20: ...set your heating unit on a lower setting without affecting your comfort Please however refer to point 10 in Safety Tips when operating in this position NOTE Turn off and wait for fan to stop before c...

Страница 21: ...e permite ajustar la calefacci n a un nivel m s bajo sin que afecte su comodidad De todos modos por favor consulte el punto 10 de las Sugerencias de seguri dad cuando utilice el ventilador en esta pos...

Страница 22: ...ubber band 4 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control 5 Allow break in period of 24 hours Most noises associate...

Страница 23: ...de los controles de velocidad variable de estado s lido para motores NO USE un control de velocidad variable de estado s lido 5 Permita el rodaje del ventilador durante un per odo de 24 horas La mayo...

Страница 24: ...24 UL ES Xavier WH05 UL_Xavier_72265 12 13 05 9 18 AM Page 24...

Страница 25: ...25 UL ES Xavier WH05 UL_Xavier_72265 12 13 05 9 18 AM Page 25...

Страница 26: ...26 UL ES Xavier WH05 UL_Xavier_72265 12 13 05 9 18 AM Page 26...

Страница 27: ...Blade 4 Fan Speed Switch 5 Light Control Switch 6 Capacitor 7 Hardware Pack No Descripci n 1 Soporte de montaje 2 Soporte para paleta 3 Paleta 4 Interruptor de control de velocidad para ventilador 5 I...

Страница 28: ...house Electric Corporation Made in China 2005 Westinghouse Lighting Corporation Westinghouse Lighting Corporation 12401 McNulty Road Philadelphia PA 19154 U S A Westinghouse Lighting Corporation titul...

Отзывы: