Westinghouse Outdoor Power Equipment | 15
PROGRAMMING THE GENERATOR FOR
REMOTE START
NOTICE
The key fob included with the generator should come
already paired with the unit. If it does not you can
follow the directions below to reconnect. If your unit
was shipped without a key fob please contact our
customer support team.
WARNING
Always make sure the area around
the generator is clear of bystanders
before using the remote start to start
the generator.
The generator can be started remotely from up to a
maximum of 100 feet away using the remote start key
fob with new, fully charged batteries in the key fob. As
the batteries’ state of charge in the key fob reduces, the
distance to start the generator will also reduce.
Before the generator can be started, an initial start-up
procedure must be performed so the generator and the
key fob recognize each other. If the key fob is replaced,
you will need to go through this procedure with the new
fob.
1. Turn the engine control switch to the RUN position.
2.
Push and hold the red
REMOTE PAIRING
button
on the control panel (or side of control panel) for 3
seconds.
3.
Press and hold the
STOP
button on the remote
start key fob until the indicator light (see 1 below)
flickers.
Figure 7 – Remote Start Key Fob
1 - Pairing Indicator light
2 - Start Button | 3 - Stop Button
4.
Press and hold the
START
button on the remote
start key fob until the indicator light at the top of the
remote flickers once.
5.
Press and hold the
REMOTE PAIRING
button on
the generator for 3 seconds. The generator is now
programmed to start remotely
OPERATION
START
STOP
1
2
3
BEFORE STARTING THE GENERATOR
BEFORE STARTING THE GENERATOR,
REVIEW SAFETY SECTION STARTING
ON PAGE 5.
Before attempting to start the generator,
verify the following:
• The engine is filled with engine oil. See
Checking
Engine Oil
on page 19.
• The generator is situated in a proper location
(Location Selection on page 12).
• The generator is on a dry surface (
Weather and Dry
Surface
on page 12).
• All loads are disconnected from the generator (
No
Connected Loads
on page 12).
• The generator is properly grounded the Generator
(page 12).
DANGER
Never use the generator in a location
that is wet or damp. Never expose the
generator to rain, snow, water spray or
standing water while in use. Protect
the generator from all hazardous
weather conditions. Moisture or ice
can cause a short circuit or other
malfunction in the electrical circuit.
Never operate the generator in an
enclosed area. Engine exhaust
contains carbon monoxide. Only
operate the generator outside and
away from windows, doors and vents.
NOTICE
The engine is equipped with a low oil shutdown
switch. If the oil level becomes low, the engine may
shut down and not start until the oil is filled to the
proper level. Poor oil quality may interfere with the
operation of the low oil shutdown switch.
The owner of the generator is responsible to ensure
the proper oil level is maintained during the operation
of the generator. Failure to maintain the proper oil
level can result in engine damage.
This generator is equipped with an automatic choke
for starting. This system is always on and cannot
be turned off. Do not attempt to make adjustments
to the automatic choke or any other carburetor
adjustments. Tampering with the automatic choke
system may void your warranty. See an authorized
Westinghouse service center for more information.
Содержание WPro12000
Страница 26: ...26 Westinghouse Outdoor Power Equipment WPro8500 EXPLODED VIEW...
Страница 28: ...28 Westinghouse Outdoor Power Equipment WPro8500 ENGINE VIEW...
Страница 30: ...30 Westinghouse Outdoor Power Equipment WPro8500 SCHEMATIC WPro8500...
Страница 31: ...Westinghouse Outdoor Power Equipment 31 WPro12000 EXPLODED VIEW...
Страница 33: ...Westinghouse Outdoor Power Equipment 33 WPro12000 ENGINE VIEW...
Страница 35: ...Westinghouse Outdoor Power Equipment 35 WPro12000 SCHEMATIC WPro12000...
Страница 60: ...60 Westinghouse Outdoor Power Equipment Version 2 28 18KD...