Westinghouse Outdoor Power Equipment | 11
GFCI Circuit Breaker:
The main circuit breaker
controls total output of all outlets to protect the
generator. This GFCI breaker allows for full panel
GFCI and is OSHA compliant.
120-Volt, 20-Amp Duplex Outlets
(NEMA 5-20R):
Each outlet is capable of carrying
a maximum of 20 amps on a single receptacle or
a combination of both receptacles.
20-Amp Circuit Breakers:
Each circuit breaker
limits the current that can be delivered through
the 120-volt duplex outlets to 20amps.
120-Volt, 30-Amp Twist Lock Outlet
(NEMA L5-30R):
Outlet can supply
120V up to 30 amps.
120/240-Volt, 30-Amp Twist Lock Outlet
(NEMA L14-30R):
Outlet can supply either
120V or 240V up to 30 amps.
120/240-Volt, 50-Amp Outlet (NEMA 14-50R):
Outlet can supply either 120V or 240V up
to 50 amps.
Ground Terminal:
The ground terminal is used to
ground the generator.
Remote Start Program Button:
Use this button
along with the key fob to program the generator
to be started remotely. Button located on side of
control panel on WPro12000.
Engine Control Switch/Battery Disconnect:
• START - When the switch is momentarily
depressed and held in the
START
position,
the electric start motor engages and starts the
engine. Once the engine starts, release the
switch. (The switch will automatically go to the
RUN
position).
• RUN - Once started, the switch will remain in the
RUN
position
• STOP - To stop the engine, move the switch to
the
STOP
position. The battery will disconnect in
the
STOP
position to save battery life.
Battery Charging Port:
Charge the battery when
the unit is off with trickle charger.
USB Duplex:
Two 5V DC USB ports.
Data Center:
This VFT Meter is a four function unit.
Function 1 will be the first thing you see. This is
your Frequency. Press the button once and you will
go to the function 2, which is not being used. Press
the button once more and you will see function 3
for your time/Hours and by pressing one final time
you will see function 4, which is the voltage.
The frequency and voltage can vary +/- 5% and
still be within tolerance.
CONTROL PANEL FEATURES
1
8
9
10
11
12
2
3
4
5
6
7
2
3
4
4
3
5
6
7
8
9
11
12
11
9
10
8
7
6
5
2
1
1
FEATURES
F - 6 0
0 0 0 0
0 0 0 7
U 2 5 0
Frequency
Inoperative
Lifetime run hours
Voltage
Содержание WPro12000
Страница 26: ...26 Westinghouse Outdoor Power Equipment WPro8500 EXPLODED VIEW...
Страница 28: ...28 Westinghouse Outdoor Power Equipment WPro8500 ENGINE VIEW...
Страница 30: ...30 Westinghouse Outdoor Power Equipment WPro8500 SCHEMATIC WPro8500...
Страница 31: ...Westinghouse Outdoor Power Equipment 31 WPro12000 EXPLODED VIEW...
Страница 33: ...Westinghouse Outdoor Power Equipment 33 WPro12000 ENGINE VIEW...
Страница 35: ...Westinghouse Outdoor Power Equipment 35 WPro12000 SCHEMATIC WPro12000...
Страница 60: ...60 Westinghouse Outdoor Power Equipment Version 2 28 18KD...