Westinghouse WPAC10000 Скачать руководство пользователя страница 13

Westinghouse Outdoor Power Equipment | 13

OPERATION

CONTROL PANEL

OPERATION

2

5

1

3

4

6

7

8

9

10

11

1. +/- Buttons:

 In cooling mode, press “+” or “-” button 

to increase or decrease set temperature by 1°F (°C). 

Set temperature range is 61°F (16°C)~86°F(30°C). 

In dry or fan mode, this button is invalid.

2. Display: 

Shows the set temperature in cooling mode.

3. Cool Mode Indicator

: When lit, unit is operating 

in cool mode. The display shows set temperature. 

Temperature setting range is 61°F (16°C)~86°F(30°C).

4. Dry Mode Indicator: 

When lit, unit is operating in dry 

mode. Display will be blank.

5. Fan Mode Indicator: 

When lit, unit is operating in 

fan mode. Display will be blank.

6. Mode Button:

 Press this button to change modes 

(Cool > Dry > Fan)

7. Timer Button

: Press this button and the mode will 

circulate according to below sequence:
Press timer button to enter into timer setting mode. 

Under this mode, press “+” or “-“ button to adjust the 

timer setting. Timer setting will increase or decrease 

0.5 hour by pressing “ + “ or “ -“ button within 10 hours, 

while timer setting will increase or decrease 1 hour by 

pressing “+” or “ “ button beyond 10 hours. After timer 

setting is finished, the unit will display temperature if 

there’s no operation for 5s. If timer function is started 

up, the upper indicator will keep the display status. 

Others, it won’t be displayed. In timer mode, press 

timer button again to cancel timer mode

8. ON/OFF Button: 

Use to turn the air conditioner on 

or off.

9. Sleep Button: 

Press sleep button to enter into sleep 

mode. If the controller operates at cooling mode, after 

sleep mode is started up, preset temperature will 

increase by 2°F(1°C) within 1 hour; preset temperature 

will increase by 4°F (2°C) within 2 hours and then the 

unit will operate at this temperature all the time; Sleep 

function is not available for fan mode or drying mode. 

If sleep function is started up, the upper indicator will 

keep the display status. Others, it won’t be displayed.

10. Fan Button: 

Press to move through fan modes 

(Low speed > Medium speed > High speed > 

Auto)

11. Fan Speed Indicator: 

Lights to show current fan 

speed.

Содержание WPAC10000

Страница 1: ...USER MANUAL Portable Room Air Conditioner Models WPAC8000 WPAC10000 DO NOT RETURN THIS PRODUCT TO THE STORE If you have questions or need assistance please call customer service at 855 944 3571...

Страница 2: ...wed in any form without written permission from Westinghouse Outdoor Power Equipment Read this manual before using or performing maintenance on this product Failure to follow the instructions and safe...

Страница 3: ...MANUAL FOR FUTURE REFERENCE PRODUCT REGISTRATION For trouble free warranty coverage it is important to register your Westinghouse generator You can register by Completing and mailing the product regis...

Страница 4: ...out the power plug Ensure that the power cord is undamaged Do not pull or drag the power cord to pull out the power plug or move the air conditioner Do not insert or pull out the power plug with wet h...

Страница 5: ...lso lower R32 has very good thermodynamic features and high energy efficiency The units therefore need less filling Appliance filled with flammable gas R32 Appliance shall be installed operated and st...

Страница 6: ...tdoor Power Equipment INSTALLATION INSTALLATION UNIT OVERVIEW 2 5 Louver vent Exhaust connector 1 Control panel 1 2 3 4 7 6 3 Caster 4 Filter 5 8 9 Remote control 6 Exhaust duct 7 Window clip 8 Power...

Страница 7: ...as far away as possible from fluorescent lighting Do not install in laundry area POWER REQUIREMENTS Follow all electrical safety regulations when installing the unit Use a qualified power supply circ...

Страница 8: ...ly Do not operate the air conditioner in a humid environment Keep air inlet and air outlet clean and free of obstacles Reserved space around the air conditioner 30cm 12 inches INSTALL EXHAUST DUCT Whe...

Страница 9: ...Tape measure or ruler Knife or scissors Saw In the event that the window panel needs to be cut down in size because the window is too narrow for direct installation INSTALL WINDOW PANEL 1 Open the wi...

Страница 10: ...gth of window panel please use the adjustment panel to make sure you can span the entire length of your window Otherwise you can add an extension panel to prolong the length of the windows panel assem...

Страница 11: ...place unit on a level surface and make sure the hose is clear of any obstructions and directed downward Placing unit on an uneven surface or improper hose installation may result in water filling up t...

Страница 12: ...dry batteries 3 Reinstall the cover of battery box Reinstall Signal sender Battery Remove Cover of battery box TEST OPERATION 1 Plug in the power supply 2 Press ON OFF button on remote control to star...

Страница 13: ...will increase or decrease 0 5 hour by pressing or button within 10 hours while timer setting will increase or decrease 1 hour by pressing or button beyond 10 hours After timer setting is finished the...

Страница 14: ...to Low Med or High 2 Buttons In cooling mode press or button to increase or decrease set temperature by 1 F C 3 Cool Mode Press to change operation to Cool mode 4 ON OFF Press this button to turn on o...

Страница 15: ...e front of the unit Adjust this louver to direct air flow 2 Press the ON OFF button from the remote or from the control panel to start the unit 3 Select operating mode Cool Fan or Dry 4 In cooling mod...

Страница 16: ...hen put it in a shady place to dry it 3 After the filter is cleaned and dried reinstall it CLEAN EXHAUST DUCT 1 Remove the exhaust duct from air conditioner clean and dry it and then reinstall it EMPT...

Страница 17: ...lease maintain it by following steps for good performance 1 Make sure there s no accumulated water in chassis and the exhaust duct is disassembled 2 Pull out the plug and wrap the power cord 3 Clean t...

Страница 18: ...g the unit wait three 3 minutes plug in again and then turn on the unit Remote control is not within receiving range The receiving range of remote control is 8 meters Do not exceed this range The rece...

Страница 19: ...o high pow er off the unit and then energize it for operation after the ambient temperature drops to 95 F 35 C below Check if the evaporator and condenser are blocked by some objects if yes take away...

Страница 20: ...ould a product difficulty occur you must at your expense deliver or ship your Westinghouse Outdoor Power Equipment LLC unit to an Authorized Service Dealer for warranty repairs which must occur within...

Страница 21: ...le Air Conditioners and its affiliated companies shall not be liable for any special incidental or consequential damage including lost profits There are no warranties extended other than as provided h...

Страница 22: ...seOutdoorPower com and Westinghouse are trademarks of Westinghouse Electric Corportaion Used under license by Westinghouse Outdoor Power Equipment All Rights Reserved WPAC8000 WPAC10000 66139902592 Re...

Отзывы: