8
9
NOTE: Distances shown to adjacent walls/surfaces are for the distance to a combustible surface. If the surface is
not combustible the measurement can be smaller than that shown.
Figure 4 - Installation cut-outs
C
B
D min
A min
INSTALLATION INSTRUCTIONS
TECHNICAL DATA
FEATURES
WHG756SA
WHG952SB
WHG956SA
Cooking zones
5
5
5
Wok
Yes
Yes
Yes
Ignition
220-240V
220-240V
220-240V
Trivet
Cast
Wire
Cast
Hob material
Stainless steel
Stainless steel
Stainless steel
Features
Ignition through knob
Ignition through knob
Ignition through knob
Flame safeguard
Yes
Yes
Yes
Colours
Stainless steel
Stainless steel
Stainless steel
Gas Types
NG, (LP conversion
kit supplied)
NG, (LP conversion
kit supplied)
NG, (LP conversion
kit supplied)
Cooktop
dimension (mm)
Width
745
895
895
Depth
530
530
530
Height*
50
50
50
Cutout
dimension (mm)
Width
730
880
880
Depth
490
490
490
Energy rating
(NG) - MJ/h
Small burner
5.1
5.1
5.1
Medium burner
2 x 9.0
2 x 9.0
2 x 9.0
Large burner
12.1
12.1
12.1
Wok burner
14.4
14.4
14.4
Total MJ/h
49.6
49.6
49.6
*Height is distance from the top of the kitchen bench to the bottom of the cooktop
INSTALLATION INSTRUCTIONS
MODEL CODE
DIMENSION (MM)
GAS SUPPLY
LOCATION
A
B
C
D
(LEFT OR RIGHT)
WHG644SA
143
560
490
145
Left
WHG646SA
143
560
490
145
Left
WHG756SA
146
730
490
145
Left
WHG952SB
121
880
490
145
Left
WHG956SA
121
880
490
145
Left
This appliance must be installed by an authorised person
and in compliance with:
1. AS/NZS 5601.1 Gas Installations Part 1: General
Installations, and AS/NZS 5601.2 Gas Installations
Part 2: LP Gas installations in caravans and boats for
non-propulsive purposes, or the relevant installation
code for gas appliances in your country.
2. The local gas fitting regulations, municipal building
codes, electrical wiring regulations and any other
relevant statutory regulations.
3. The particular instructions as given below.
WARNING
CAUTION
Cooktops are supplied for use with natural gas (NG).
To use with LPG the injectors MUST be changed using
the conversion kit supplied. Refer LP Conversion on page
12 and 13.
4. A certificate of compliance MUST be given to the
customer after the appliance is successfully installed.
5. This appliance must be earthed.
TECHNICAL DATA (CONTINUED)