PART 8 – CONTROLS
A. CONTROL AND DISPLAY OVERVIEW
Detailed Description of Button
Functions
1. Setting Adjust Down
2. Setting Adjust Up
3. Decreases the User Setpoint
4. Increases the User Setpoint
5. ECO Mode
6. RESET
7. OFF / Mode Enable
Detailed Description of Control Functions
MODES OF OPERATION
MODE
SCREENSHOT
DESCRIPTION
RANGE (DEFAULT)
Off Mode
The water heater will ignore heat demands while in Off Mode.
To put the water heater into Off Mode, press
.
Off / On (Off)
Stand-By
Mode
In Stand-By Mode, the fan is off, the gas valve is closed, and
the water inlet shut-off valve is opened.
The water heater goes into Stand-By Mode when it is powered
but not firing.
On Winter / On
Summer / Off (Off)
User
Setpoint
The User Setpoint is used to set the temperature for the water
heater.
Press either
or
once to change the User Setpoint.
The normal operation screen will clear and be replaced by a
flashing number. This is the User Setpoint.
Press
to decrease or
to increase the setpoint in
increments of two degrees. After choosing the setpoint, wait
five seconds. The screen will return to normal operation and
the setpoint will be stored.
70
– 160
(120)
Outdoor
Reset Curve
Enabling Outdoor Reset Curve allows the user to set
additional parameters to increase water heater efficiency.
An Outdoor Sensor is required to set Outdoor Reset Curve.
See Advanced Control Functions to set the Outdoor Reset
Curve.
0 = Enabled, 1 =
Disabled (0)
Figure 22
– Control Detail
Содержание WGR050LP076
Страница 34: ...34 WHL 001 REV 9 3 14 Figure 14...
Страница 53: ...53 WHL 001 REV 9 3 14 Figure 25 Replacement Parts...
Страница 54: ...54 WHL 001 REV 9 3 14 Figure 26 Replacement Parts...
Страница 57: ...57 WHL 001 REV 9 3 14...
Страница 58: ...58 WHL 001 REV 9 3 14...
Страница 59: ...59 WHL 001 REV 9 3 14 MAINTENANCE NOTES...