background image

24 | Westinghouse Outdoor Power Equipment, LLC

 

BATTERY MAINTENANCE

WARNING

Explosion hazard. Batteries emit explosive gases while 

charging. Keep fire and spark away. 

The battery shipped with the generator has been fully 

charged. A battery may lose some charge when not in use 

for prolonged periods of time.  

Note: 

Once started, the generator will charge the battery 

after 30–60 minutes of use.  

The included trickle charger can remain connected and 

will maintain the battery for an indefinite period of time. A 

red light on the charger indicates charging in progress. A 

green light indicates charging complete. Charge in a dry 

location. 

1. 

Plug the charger into the battery charging port on the 

control panel. 

2. 

Plug the wall receptacle end of the battery charger into 

a 120 Volt AC wall outlet.

BATTERY REPLACEMENT

WARNING

Burn hazard. The battery contains sulfuric acid 

(electrolyte) which is highly corrosive and poisonous. 

Wear protective clothing and eye protection when 

working near the battery. Keep children away from the 

battery. 

CAUTION

Battery posts, terminals contain lead and lead 

compounds. Wash hands after handling. 

1. 

Loosen and remove the bolt on the battery hold-down 

plate and swing the plate out. 

2. 

Disconnect the quick-connect plugs and remove the 

battery from the unit. 

3. 

Disconnect the quick-disconnect cable leads from the 

battery. 

4. 

On the replacement battery, connect the white (-) quick-

connect cable to the battery negative terminal. Slide the 

rubber boot over the connection hardware. 

5. 

Connect the red (+) quick-connect cable to the battery 

positive terminal. Slide the rubber boot over the 

connection hardware. 

6. 

Install the battery into the generator. Reinstall the battery 

hold-down plate and tighten the bolt. 

7. 

Connect the quick-connect plug. 

NOTICE

Dispose of the used battery properly according to the 

guidelines established by your local or state government.

STORAGE

Proper storage preparation is required for trouble-free 

operation and generator longevity.  

NOTICE

Gasoline stored for as little as 30 days can deteriorate, 

causing gum, varnish, and corrosive buildup in fuel lines, 

fuel passages, and the engine. This corrosive buildup 

restricts the flow of fuel, which can prevent the engine 

from starting after a prolonged storage period. The use 

of fuel stabilizer significantly increases the storage life of 

gasoline. Full-time use of fuel stabilizer is recommended. 

Follow the manufacturer’s instructions for use. 

STORAGE TIME

RECOMMENDED PROCEDURE

Less than 1 month

No service required.

2 to 6 months

Fill with fresh gasoline and add 

gasoline stabilizer. Drain the 

carburetor float bowl.

6 months or longer

Drain the fuel tank and carburetor 

float bowl. 

SHORT TERM STORAGE

•  Allow the generator to cool a minimum of 30 minutes 

before storage.  

•  If operating on LPG, turn the propane tank valve to the 

fully closed position and disconnect the LPG/propane 

hose from the generator and propane tank. 

•  Replace all protective covers on the generator control 

panel. 

•  Wipe the generator with a moist cloth. Clean any debris 

from the muffler cooling vents.   

•  Store the generator in a well-ventilated, dry location 

away from sparks, open flames, pilot lights, heat, and 

other sources of ignition such as areas with a spark-

producing electric motor or where power tools are 

operated. 

• 

DO NOT

 store the generator, gasoline, or propane tanks 

near furnaces, water heaters, or any other appliances 

that produce heat or have automatic ignitions.

•  With the engine and exhaust system cool and all 

surfaces dry, cover the generator to keep out dust. 

DO 

NOT

 use a plastic sheet as a dust cover. Non-porous 

materials trap moisture and promote rust and corrosion. 

MAINTENANCE

Содержание WGen7500c

Страница 1: ...SER MANUAL DO NOT RETURN THIS PRODUCT TO THE STORE If you have questions or need assistance please call customer service at 855 944 3571 WGen7500c Portable Generator 7500 Running Watts 9500 Peak Watts...

Страница 2: ...anual can result in serious injury or death SAVE THESE INSTRUCTIONS TABLE OF CONTENTS INTRODUCTION DISCLAIMERS 2 ALL RIGHTS RESERVED 2 SPECIFICATIONS 3 SAFETY SAFETY DEFINITIONS 4 SAFETY SYMBOLS 4 SAF...

Страница 3: ...s up to 104 F 40 C If needed this product can be operated at temperatures ranging from 5 F 15 C 122 F 50 C for short periods If the product is exposed to temperatures outside of this range during stor...

Страница 4: ...voided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE Indicates a situation which can cause damage...

Страница 5: ...ly installed and the electrical output has been verified by a qualified electrician The connection must isolate the generator power from utility power and must comply with all applicable laws and elec...

Страница 6: ...allow the generator s gas tank to overflow when filling Shut down the engine and allow it to cool for two minutes before adding gasoline or oil to the generator NEVER remove the fuel cap when the gene...

Страница 7: ...ttery powered carbon monoxide alarm s in your home WARNING Automatic shutoff accompanied with a flashing RED light in the CO Sensor portion of the control panel is an indication that the generator was...

Страница 8: ...the TEST C button located on the front of the receptacle to trip the device This should immediately stop the flow of electricity and shut off the lamp If the electricity is not stopped DO NOT use this...

Страница 9: ...Westinghouse Outdoor Power Equipment LLC 9 SAFETY LABELS AND DECALS SAFETY...

Страница 10: ...s Receptacles can supply a maximum of 20 Amps 6 120 Volt AC 20 Amp Duplex GFCI NEMA 5 20R Receptacles Receptacles can supply a maximum of 20 Amps 7 20 Amp AC Circuit Breakers Circuit breakers limits t...

Страница 11: ...Westinghouse Outdoor Power Equipment LLC 11 COMPONENTS GENERATOR COMPONENTS...

Страница 12: ...Assembly wrench Wheel and mounting foot components Item Quantity Mounting foot 2 Flange bolt M8 4 Wheel 2 Axle pin 2 Washer 2 Cotter pin 2 If any parts are missing contact our service team at service...

Страница 13: ...fuel item that is broken cut torn or damaged DANGER Fire and explosion hazard DO NOT overfill fuel tank Fill only to the red fill ring located in the in tank fuel screen filter Overfilling may cause f...

Страница 14: ...e red maximum fill ring on the fuel screen filter visible in the filler neck 5 Install the fuel cap NOTICE Fuel can damage paint and plastic Use caution when filling the fuel tank Damage caused by spi...

Страница 15: ...tairs next to walls or buildings or in any other location that will not allow for adequate cooling of the generator and or the muffler DO NOT contain generators during operation DANGER Asphyxiation ha...

Страница 16: ...anel If your unit was shipped without a key fob contact Westinghouse customer service The generator can be started remotely from up to 99 feet 30 meter using the remote start key fob Note As the batte...

Страница 17: ...he choke and begin the start sequence If the engine fails to start the generator will attempt to start the engine two more times STOPPING THE ENGINE 1 Turn off and unplug all connected electrical load...

Страница 18: ...Conditioner 11 000 BTU 1010 1600 TV Tube Type 300 0 RV Refrigerator 180 600 Radio 200 0 Light 75 Watts 300 0 Coffee Maker 600 0 2590 Total Running Watts 1600 Highest Starting Watts Total Running Watts...

Страница 19: ...resulting in death or serious injury Before connecting an AC appliance or power cord to the generator Use grounded 3 prong extension cords tools and appliances or double insulated tools and appliance...

Страница 20: ...unit level during transport to minimize the possibility of fuel leakage or if possible drain the fuel or run the engine until the fuel tank is empty before transport The generator wheels are only int...

Страница 21: ...ime Hours The maintenance codes will be displayed until the unit is turned off Refer to the Maintenance section for specific procedures Maintenance Code Required Maintenance P25 Change engine oil P50...

Страница 22: ...eather change the oil more frequently Ambient air temperature will affect engine oil performance Change the type of engine oil used based on weather conditions Check the engine oil level before each u...

Страница 23: ...the spark boot directly away from the engine 3 Clean the area around the spark plug 4 Remove the spark plug with the included spark plug socket wrench NOTICE NEVER apply any side load or move the spa...

Страница 24: ...nnect the quick connect plug NOTICE Dispose of the used battery properly according to the guidelines established by your local or state government STORAGE Proper storage preparation is required for tr...

Страница 25: ...Start the generator and allow it to run until the generator engine stops 5 Push the battery switch to the OFF position 6 Disconnect the battery quick connect plugs 7 Remove the spark plug 8 Put a teas...

Страница 26: ...rocker arms should be loose at TDC on the compression stroke If they are not rotate the engine 360 5 Insert a feeler gauge between the rocker arm and the valve stem to measure valve clearance Intake...

Страница 27: ...service toll free at 1 855 944 3571 Engine starts then shuts down Out of fuel Refuel Incorrect engine oil level Check engine oil level Dirty air filter Clean the air filter Contaminated fuel Drain th...

Страница 28: ...28 Westinghouse Outdoor Power Equipment LLC EXPLODED VIEWS AND PARTS LISTS EXPLODED VIEW A EXPLODED VIEWS...

Страница 29: ...MBLY 9 1 271005 CYLINDER HEAD 9 2 271702 INTAKE VALVE 9 3 275902 EXHAUST VALVE NO PART DESCRIPTION 9 4 261807 INTAKE VALVE SPRING LOWER SEAT 9 5 93513 VALVE SEAL 9 6 266002 VALVE SPRING 9 7 260802 VAL...

Страница 30: ...WHEEL NUT 15 RECOIL STARTER ASSEMBLY 15 1 91325 BOLT M6X12 15 2 264738 221B STARTER ASSEMBLY 15 2 1 5910 221 RECOIL STARTER 15 2 2 5943 HANDLE 16 STARTER MOTOR ASSEMBLY 16 1 97415 STARTING MOTOR 16 2...

Страница 31: ...Westinghouse Outdoor Power Equipment LLC 31 EXPLODED VIEW B EXPLODED VIEWS...

Страница 32: ...120030 ENGINE ASSEMBLY 4 3 549603 DUST BOARD 4 4 91322 BOLT M5X12 4 5 90016 NUT M6 4 6 539602 CRANKCASE COVER 5 CARBON CANNISTER ASSEMBLY NO PART DESCRIPTION 5 1 95123 CARBON CANISTER AND FUEL TANK C...

Страница 33: ...23 BOLT M5X16 10 14 544610 SHORT WIRE 11 BATTERY BRACKET ASSEMBLY 11 1 91327 BOLT M6X12 11 2 542614 116 BATTERY PRESSURE PLATE 11 3 512058 BATTERY WIRING ASSEMBLY 11 4 91325 BOLT M6X12 12 CO MODULE AS...

Страница 34: ...34 Westinghouse Outdoor Power Equipment LLC SCHEMATICS SCHEMATICS SCHEMATICS...

Отзывы: