Westinghouse W-135 Скачать руководство пользователя страница 4

4

NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires.  These
fixtures meet all UL specifications.

1.  Turn off power at circuit box to avoid possible electric shock.
2.  Secure mounting bar (A) to outlet box (B) with outlet box screws (C) (not included) (see fig. 1).
3.  Thread hex nut 1 (D1) onto mounting nipple (E) approximately 1/4 inch and insert lock

washer (F), then thread mounting nipple (E) onto mounting bar (A) and secure with hex nut
1 (D1).

4.  Thread nipple 1 (G1) onto coupling 1 (H1).
5.  Secure fixture loop (J) to fixture cover (I). 

NOTE:  Do not twist or kink wires. 

6.  Thread hex nut 2 (D2) onto nipple 2 (G2), then thread nipple 2 (G2) into coupling 2 (H2) on

fixture base (K) and secure with hex nut 2 (D2).

7.  Open one link on bottom end of chain (L). Attach to fixture loop (J). Securely close link on 

chain (L).

8.  Thread screw collar ring (M) onto screw collar (N), then place canopy (O) over top of screw

collar (N).

9.  Lace wires up through every other link on chain (L) then through screw collar (N), canopy

(O) and mounting nipple (E).

10.  Open one link on top end of chain (L). Attach to loop on screw collar (N). Securely close 

link on chain (L).

11.  Identify color coding of fixture wires (see fig. 2).
12.  To connect wires, take black fixture wire (group A from fig. 2) and place evenly against

black outlet box wire. Do not twist wires.

13.  Fit wire connector (P from fig. 1) over wires and twist until there is a firm connection. If

wire connector (P) easily comes off, reattach and check again for a firm connection.

14.  Repeat steps 12 and 13 with the white (group B from fig. 2) fixture wires and outlet box wires.

15.  Partially thread green grounding screw (Q) into side hole (R) on mounting bar (A) (see fig. 1).
16.  Wrap ground wire from fixture around green grounding screw (Q) leaving enough excess 

wire to then connect ground wire and outlet box wire with wire connector (P) (see step 13) 
(if applicable).

17.  Tighten green grounding screw (Q). Do not over tighten.
18.  Remove screw collar ring (M) from screw collar (N) and secure screw collar (N) to mounting

nipple (E).

19.  Tuck wires inside outlet box (B).

20.  Raise canopy (O) to ceiling and secure screw collar ring (M) to screw collar (N).

MOUNTING AND WIRING INSTRUCTIONS

FIXTURE ASSEMBLY INSTRUCTIONS

1.  Install lamps. Do not exceed recommended wattage.
2.  Raise glass shade (S) up to fixture cover (I) with nipple 2 (G2) protruding through opening 

in glass shade (S).

3.  Carefully support glass shade (S) while placing cover (T) and bottom break (U) over nipple 

2 (G2) and secure with finial (V). 

4.  Turn power back on at circuit box. 

12 pg_W-135_EFS  6/8/07  6:23 AM  Page 4

Содержание W-135

Страница 1: ...or incluya el n mero del modelo aqu para futura referencia Owner s Manual Guide d utilisation Manual del Usuario Outdoor Lighting Fixture Installation Instructions Instructions d installation Appareil...

Страница 2: ...hall repair or replace the fixture or refund the purchase price WARNING ELECTRICAL SHOCK CAN RESULT IN SERIOUS INJURY Read and follow instructions exactly as shown If instructions are unclear do not p...

Страница 3: ...CREW Q WIRE CONNECTORS P GROUND WIRE OUTLET BOX SCREWS C MOUNTING BAR A SIDE HOLE R NIPPLE 2 G2 LOCK WASHER F CANOPY O GLASS SHADE S COVER T CHAIN L FIXTURE LOOP J FINIAL V SCREW COLLAR RING M SCREW C...

Страница 4: ...fig 2 12 To connect wires take black fixture wire group A from fig 2 and place evenly against black outlet box wire Do not twist wires 13 Fit wire connector P from fig 1 over wires and twist until the...

Страница 5: ...nghouse Lighting qui sa discr tion r parera ou rem placera l appareil ou vous remboursera le montant du prix d achat 5 MISE EN GARDE L LECTROCUTION POURRAIT CAUSER DE GRAVES BLESSURES PERSONNELLES Lis...

Страница 6: ...S DE LA BOITE DE SORTIE DE COURANT C BARRE DE FIXATION A TROU LATERAL R MANCHON FILETE 2 G2 RONDELLE DE BLOCAGE F ECROU DECORATIF V CHAPEAU O ABAT JOUR EN VERRE S COUVERCLE T CHAINE L LA BOUCLE DE L A...

Страница 7: ...Afin de brancher les fils prenez le fil noir de l appareil d clairage groupe A fig 2 et placez le de fa on gale sur le fil noir provenant de la bo te de sortie de courant Ne tournez pas les fils ense...

Страница 8: ...ing a su criterio reparar o reemplazar el artefacto o le rein tegrar el precio de compra ADVERTENCIA UNA DESCARGA EL CTRICA PODR A CAUSAR LESIONES Lea y siga las instrucciones exactamente como se indi...

Страница 9: ...RNILLOS CAJA DE EMBUTIR C BARRA DE MONTAJE A ORIFICIO LATERAL R NIPLE 2 G2 ARANDELA DE PRESION F DOSEL O PANTALLA DE VIDRIO S CUBIERTA T FLORON V CADENA L FIJELO AL ASA DEL ARTEFACTO J ENROSQUE EL ANI...

Страница 10: ...de los cables de su artefacto vea la Fig 2 12 Para conectar los cables tome el cable negro del artefacto grupo A de la Fig 2 y col quelo uni formemente contra el cable negro de la caja de embutir No...

Страница 11: ...cas des fils parall les SPT I et SPT II le fil neutre est carr et C tel et le fil charg est rond et lisse Voir ci dessus MISE EN GARDE Coupez le courant au site de montage avant de commencer l install...

Страница 12: ...tive covering NETTOYAGE ET ENTRETIEN Pour nettoyer essuyez l appareil avec un linge doux Nettoyez le verre l aide d un savon doux Les net toyants chimiques risquent de d colorer le fini de l appareil...

Отзывы: