TROUBLESHOOTING GUIDE

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some cases, these

installation errors may be mistaken for defects. If you experience any faults, please check this Trouble Shooting Chart. If a problem cannot

be remedied, please consult with your authorized electrician and do not attempt any electrical repairs yourself.

TROUBLE 

1. If fan does not start:

2. If fan sounds noisy: 

3. If fan wobbles:

4. If light does not work:

SUGGESTED REMEDY

1. Check main and branch circuit fuses or circuit breakers.
2. Check wire connections as performed in step #15 or #16 of installation. 

CAUTION:

Make sure main power is turned off.

3. Make sure slide switch is pushed firmly to one side or the other. The fan will not operate with the slide switch in the middle.
4. If the fan still will not start, contact a qualified electrician. Do not attempt to troubleshoot internal electrical connections yourself.

1. Check to make sure all screws in motor housing are snug (not over tightened).
2. Check to make sure the screws which attach the fan blade holder to the motor are tight.
3. If using an optional Ceiling Fan Light Kit, check to be sure the screws securing the glassware are finger tight. Check to be sure light bulb is tight in socket and not 

touching glass shade(s). If vibration persists from glass, remove glass and install a 6mm wide rubber band on glass neck to act as an insulator. Replace glass and 
tighten screws against rubber band.

4. Some fan motors are sensitive to signals from Solid State variable speed controls. DO NOT USE a Solid State variable speed control.
5. Allow “break-in” period of 24 hours. Most noises associated with a new fan will disappear after this period.

All blades are weighed and grouped by weight. Natural woods vary in density which could cause the fan to wobble even though all blades are weight-matched.
The following procedures should eliminate most of the wobble. Check for wobble after each step.

1. Check that all blades are screwed firmly into blade holders.
2. Check that all blade holders are tightened securely to motor.
3. Make sure that canopy and mounting bracket are tightened securely to ceiling joist.
4. Most fan wobble problems are caused when blade levels are unequal. Check this level by selecting a point on the ceiling above the tip of one of the 

blades.Measure this distance as shown in Figure 1. Keeping measure within 3mm, rotate the fan until the next blade is positioned for measurement. 
Repeat for each blade. If all blade levels are not equal, you can adjust blade levels by the following procedure. To adjust a blade tip up, insert a washer (not supplied) 
between the blade and blade holder at the screw closest to the motor (Figure 2). To adjust a blade tip down, insert washer (not supplied) between the blade and blade 
holder at the two screws farthest from the motor (Figure 2).

5. If blade wobble is still noticeable, interchanging two adjacent (side by side) blades can redistribute the weight and possibly result in smoother operation.

1. Check to see that molex connector in the switch housing is connected
2. Check for faulty light bulbs.
3. If light kit will still not operate, contact a qualified electrician for assistance.

Figure 1

Touching

Ceiling

Blade Tip Down:

Fan Blade

Blade Brackets

Figure 2

Blade Tip Up:

Fan Blade

UL_TurboSwirl  1/18/05  12:15 PM  Page 20

Содержание Turbo Swirl

Страница 1: ...R S MANUAL MANUAL DEL USUARIO MR N W 5 2 KGS G W 5 7 KGS Turbo SwirlTM Please write model number here for future reference Por favor incluya el n mero del modelo aqu para futura referencia UL_TurboSwi...

Страница 2: ...cing or during cleaning Do not insert foreign object between rotating blades 10 Attach the mounting bracket using only the hardware supplied with the outlet box Fan is only to be mounted to an outlet...

Страница 3: ...ndo s lo la torniller a suministrada con la caja de embutir El ventilador s lo se debe montar en una caja de embutir marcada Acceptable for Fan Support Aceptable para soportar ventiladores 11 Para red...

Страница 4: ...cielorrasos normales VAULTED CEILING INSTALLATION INSTALACI N PARA CIELORRASOS ABOVEDADOS May require a longer downrod sold separately Podr a requerir una varilla vertical m s larga se vende por sepa...

Страница 5: ...ARING FOR INSTALLATION ANTES DE LA INSTALACI N Quite el envoltorio e inspeccione detenidamente el ventilador para verificar que todas las piezas est n incluidas Apague la alimentaci n en la caja de fu...

Страница 6: ...ating slots 2 on the canopy Rotate the mounting bracket counter clockwise and remove from the canopy Quite los tornillos y las dos arandelas en estrella de los dos orificios coincidentes 1 del dosel A...

Страница 7: ...option is selected proceed to page 8 step 6 OPCI N DE INSTALACI N AL RAS Si elige la opci n de montaje al ras proceda a la p gina 8 paso 6 NORMAL DOWNROD OPTION If installing downrod supplied with fa...

Страница 8: ...e al ras y las arandelas de presi n incluidas Apriete los tornillos asegur ndolos 7 For flush mount option raise fan assembly and place onto hook from mounting bracket into a closed hole on the canopy...

Страница 9: ...de la varilla vertical y el de la horquilla de la varilla vertical est n alineados Instale el pasador transversal de la horquilla 1 pas ndolo por la horquilla y la varilla vertical Inserte el pasador...

Страница 10: ...drilled hole exists in the extended downrod tighten the set screw against the downrod to secure the downrod ball Vuelva a instalar el pasador en la varilla vertical m s larga y deslice la esfera de la...

Страница 11: ...rtical conjunto del dosel e inserte la varilla vertical en la horquilla de la misma Aseg rese de que el orificio de la varilla vertical y el de la horquilla de la varilla vertical est n alineados Inst...

Страница 12: ...e cableado 13 1 2 Carefully lift fan assembly onto mounting bracket Rotate fan until notch on downrod ball 1 engages the ridge on the mounting bracket 2 This will allow for hands free wiring Levante c...

Страница 13: ...om n Negro vivo Azul vivo Principal tierra Blanco com n Interruptor del ventilador vivo Interruptor de la luz vivo Verde de tierra Del Ventilador De La Casa conectar conectar conectar conectar Conecte...

Страница 14: ...tiendo que los dos tornillos y las arandelas en estrella se deslicen dentro de las ranuras Gire el dosel en sentido horario hasta que ambos tornillos del soporte de montaje caigan adentro de las ranur...

Страница 15: ...o a trav s de los soportes para paletas luego a trav s de las almohadillas recuadro A Las almohadillas sostendr n los tornillos del motor en su sitio durante la instalaci n Fije el conjunto de las pal...

Страница 16: ...of the glass Pull the glass shade toward the third spring clip Push the third clip to fit inside the glass and push the glass up into the fitter Fije la pantalla al artefacto insertando el cuello de...

Страница 17: ...are held by lightly pulling both chains in coupling Sujetar las cadenas largas de tiro con las piezas finales correspondientes a las cadenas del ventilador introduciendo el extremo de la cadena larga...

Страница 18: ...to set your heating unit on a lower setting without affecting your comfort Please however refer to point 10 in Safety Tips when operating in this position NOTE Turn off and wait for fan to stop befor...

Страница 19: ...o le permite ajustar la calefacci n a un nivel m s bajo sin que afecte su comodidad De todos modos por favor consulte el punto 10 de las Sugerencias de seguri dad cuando utilice el ventilador en esta...

Страница 20: ...e speed controls DO NOT USE a Solid State variable speed control 5 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period All blades are weighed and g...

Страница 21: ...NO USE un control de velocidad variable de estado s lido 5 Permita el rodaje del ventilador durante un per odo de 24 horas La mayor a de los ruidos asociados con el ventilador nuevo desaparecer n desp...

Страница 22: ...22 UL ES TurboSwirl WH05 UL_TurboSwirl 1 18 05 12 15 PM Page 22...

Страница 23: ...n Speed Switch 6 Light Control Switch 7 Capacitor 8 Hardware Pack No Descripci n 1 Soporte de montaje 2 Soporte para paleta 3 Paleta 4 Pantalla de vidrio 5 Interruptor de control de velocidad para ven...

Страница 24: ...inghouse Electric Corporation Made in China 2005 Westinghouse Lighting Corporation Westinghouse Lighting Corporation 12401 McNulty Road Philadelphia PA 19154 U S A Westinghouse Lighting Corporation ti...

Отзывы: