9
This dryer is internally grounded to neutral
unless it was manufactured for sale in Canada. Grounding
through the neutral link is prohibited for: (1) new branch cir-
cuit installations, (2) mobile homes, (3) recreational vehicles,
and (4) areas where local codes do not permit grounding
through the neutral.
CIRCUIT - Individual 30 amp. branch circuit fused with 30
amp. time delay fuses or circuit breakers. Use separately
fused circuits for washer and dryer. DO NOT operate a
washer and a dryer on the same circuit.
POWER SUPPLY - 2 wire, 220-240 volt, single phase, 60Hz,
or 2 wire 220-240 volt, single phase 50 Hz Alternating
Current.
Electrical system requirements
2-WIRE POWER SUPPLY CORD KIT (not supplied)
OUTLET RECEPTACLE - receptacle to be located so the power
supply cord is accessible when the dryer is in the installed
position.
GROUNDING CONNECTION - See “Grounding requirements”
in Electrical Installation section.
The dryer MUST employ a 2-conductor power supply cord
rated at 240 volt AC minimum, 30 amp, with 2 open end
spade lug connectors with upturned ends or closed loop
connectors and marked for use with clothes dryers.
Because of potentially inconsistent voltage capabili-
ties, the use of this dryer with power created by gas pow-
ered generators, solar powered generators, wind powered
generators or any other generator other than the local utility
company is not recommended.
Exhaust system requirements
If your present system is made up of plastic duct or metal foil
duct, replace it with a rigid or semi-rigid metal duct. Also,
ensure the present duct is free of any lint prior to installing
dryer duct.
Use only 4 inch (10.2 cm) diameter (minimum) rigid or fl exible
metal duct and approved vent hood which has a swing-out
damper(s) that open when the dryer is in operation. When
the dryer stops, the dampers automatically close to prevent
drafts and the entrance of insects and rodents. To avoid
restricting the outlet, maintain a minimum of 12 inches (30.5
cm) clearance between the vent hood and the ground or any
other obstruction.
Correct
Incorrect
Correct
Incorrect
The following are specifi c requirements for
proper and safe operation of your dryer.
- FIRE HAZARD -
Failure to follow these in-
structions can create excessive drying times and fi re hazards.
- FIRE HAZARD -
Do not install a clothes
dryer with fl exible plastic or metal foil venting materials.
Flexible venting materials are known to collapse, be easily
crushed and trap lint. These conditions will obstruct clothes
dryer airfl ow and increase the risk of fi re.
2-WIRE MAIN FUSE BOX
220-240 V 50 Hz
OR 220-240 V 60 Hz
SUBJECT TO LOCAL REGULATIONS
METALLIC OR
NONMETALLIC
SHEATHED CABLE
220-240 V
POWER SUPPLY
220-240 V. 50 Hz
OR 220-240 V. 60 Hz
DRYER
TERMINAL
BLOCK
30 AMP FUSES OR
CIRCUIT BREAKER
SAFETY SWITCH
(MAY OR MAY NOT
BE FUSED)
SUGGESTED METHOD for 2-wire Supply