Controller Over-current Cut
Settings
Current Limit
represents controller
over-current cut settings. The
current value can be changed
from 7.0A to 25.0A. The default
value is 15A. To change basic
settings, press the “+” or the “-”
button to increase or decrease the
value of the current. To store a
changed setting, press the “i”
button to confirm.
Power Assistant Sensor
Magnets
Assistant Num
represents the
number of magnets in the Pedal
Assist System (PAS) disk. The
settable range is “5” to “24”. The
default value is 12. To change the
magnet number of power assist
sensor, press the “+” or the “-”
button to choose the desired
number. To store a changed
setting, press the “i” button to
confirm.
Speed Sensor
Speed Sensor
represents speed
sensor settings. To change speed
sensor settings, press the “+” or
the “-” button to select the quantity
of magnet heads on the e-bike
spoke (the range is from 1 to 15).
The default value is 1. To store a
changed setting, press the “i”
button to confirm
.
Slow Start
Slow start
represents slow start-up
settings. It is a time duration before
you get power assistance when
applying pedal power. The range is
“1-4”. “4” is the slowest. The default
value is “1”. To change slow start
up settings, press +/- button to
choose the desired value. And
press the “i” button to confirm.