![Westgate DV62 Скачать руководство пользователя страница 46](http://html.mh-extra.com/html/westgate/dv62/dv62_technical-manual_963979046.webp)
d
iagnoStic
f
laSH
codeS
1. Fail to ignite: If there is no positive ignition, the board will go into lock out and the LED will blink 3 times in
intervals until the system is reset. See Figure 96 for LED location in the unit.
2. Low battery condition (<4V): the LED indicator will blink one (1) time in intervals.
3. Parasitic Pilot Flame: the LED indicator will blink two (2) times in intervals.
4. System Lock out: the LED indicator will blink three (3) times in intervals.
Additional Ignition Information
1. The Proflame DFC Board will try two (2) times for ignition.
2. Each try for ignition will last approximately 60 seconds.
3. The wait time between the two tries is approximately 35 seconds.
Figure 95: Proflame DFC Board with LED Indicator attached.
Figure 96: LED Indicator Location.