fire BriCk instaLLatiOn seQuenCe – Westfire uniQ 32
Outer top baffle brick 1 must be held in
place and then supported by left and right
angled side bricks 2 & 3.
installation procedure:
1 Outer Top Baffle Brick
2 Left Angled Side Brick
3 Right Angled Side Brick
4 Rear Brick
5 Left Side Brick
6 Right Side Brick
7 Left Base Brick
8 Right Base Brick
9 Rear Base Brick
10 Front Base Brick
11 Base Grate
12 Log Retainer
13 Inner Top Baffle Brick
3.
8.
6.
5.
1.
13.
4.
9.
10.
11.
12.
2.
7.
Outer top baffle brick 1 must be held in
place and then supported by left and right
angled side bricks 2 & 3.
Position rear brick 4 below chrome tertiary
air bar and push angled side bricks 2 & 3 to
butt up against it.
Left and right side bricks 5 & 6 fitted.
Left and right side bricks 5 & 6 fitted.
Left base brick 7 fitted.
Right base brick 8 fitted.
Rear base brick 9 fitted.
Front base brick 10 fitted.
Base grate 11 fitted.
Inner top baffle brick 13(Angled
parallel edge at rear resting on
chrome tertiary air bar) fitted and
supported with two side pins.