8
Installation and Operation
Use for setting Blind Rivets
If the accessories for setting rivet nuts are installed, equip the device with the
accessories for setting blind rivets. To do this, loosen the tie rod guide (9) and
the union ring (2) and remove the nosepiece (1) from the device. Be careful not
to lose the spring ring in the coupling ring. Pull the knob (13) off the
Counterpart (12) and push the pull rod (10) back towards the handles. Unscrew
the counterpart (12) and take the pull rod (10) with spring (11) out of the
device.
Assemble the accessories for setting blind rivets. To do this, insert the clamping
wedges (5) into the clamping sleeve (4) in such a way that they form a cone
that protrudes from the sleeve to the front. That may take a few tries. Then
insert the pressure piece (6) and the spring (7) into the sleeve from behind and
screw the assembled clamping unit into the housing. Then place the
nosepiece (1) on the housing. The nose on the housing must engage in the
recess on the nose piece (1). Secure the nosepiece with the union ring (2).
Make sure that the spring washer is in the coupling ring. Insert the guide (3)
that matches the blind rivets into the nosepiece. Insert the collecting
container (8) into the housing from behind to catch the torn pull wires.
Spread the handles of the device apart and insert the pull wire of the blind rivet
into the guide. The clamping unit grips the puller wire, and when the handles
are brought together, the clamping unit tensions the puller wire and
compresses the rivet head and tears off the puller wire when the
predetermined pulling torque is reached.
Use for setting Rivet Nuts
If the accessories for setting blind rivets are installed, equip the device with the
accessories for setting rivet nuts. To do this, loosen the blind rivet guide (3) and
the union ring (1) and remove the nosepiece (1) from the device. Be careful not
to lose the spring ring in the coupling ring. Remove the clamping unit from the
housing. Be careful not to lose any of the individual parts of the clamping unit.
Remove the collecting container (8) from the device.
Assemble the accessories for setting rivet nuts. Insert the matching tie rod
guide (9) into the nose piece (1). Push the spring (11) over the pull rod (10) and
insert the pull rod into the housing from the front. Push the pull rod back
against the spring and secure it by screwing on the counterpart (12). The
counterpart must be mounted with the hexagon facing forward. Split the
knob (13) on the counterpart. The asymmetrical end of the pull rod must
engage in the recess in the knob so that the pull rod can be rotated with the
Operation
Содержание 96 72 89
Страница 3: ...3 1 2 3 4 5 6 7 8 13 12 11 10 9 ...