background image

Mounting and connecting the Control Box 

 

 

18 

1.  Mount  the  control  box  (2)  with 

suitable  screws  and  dowels  for  the 
resp. surface. 

Preferably  mount  the  control  box 
approx.  150  cm  above  the  ground. 
Make  sure  the  control  box  is  not 
exposed  to  direct  sunlight,  rain, 
snow or direct  water jet (high pres-
sure water jet etc.). 

2.  Unscrew the lock  nuts  of the strain 

relief and insert the power cable of the gate opener from below 
into the control box. Pull enough cable and tighten the lock nuts 
of the strain relief. 

The cables are labelled with small flags. Please observe the 
flags and arrange them correctly. 

Order of the cables for Gate Opener 1: 

Red cable to +Motor1 

Black cable to 

–Motor1 

Blue cable to ULT1 

Green cable to COM 

Yellow cable to DLT1. 

 

Order of the cables for Gate Opener 2: 

Red cable to +Motor2 

Black cable to 

–Motor2 

Blue cable to ULT2 

Green cable to COM 

Yellow cable to DLT2. 

 

Opener 1 

Opener 2 

Screws and 
dowels 
(not 
included) 

Содержание 85 27 06

Страница 1: ...Artikelnummer der Bedienungsanleitung 85 52 16 Instruction Manual Swing Gate Opener Article No 85 27 06...

Страница 2: ...ructions for further reference This operating instruction contains important details for handling the device Please pass it on along with the unit if it is handed over to a third party Please read all...

Страница 3: ...time 2 Do not allow children to operate the gate or play in the gate area 3 The gate area is for vehicles only 4 Read and understand the manual 5 Pedestrians have to use a separate entry Do not remov...

Страница 4: ...ost Pivot Bracket 2 Pieces 8 Gate Bracket 2 Pieces 9 Washer M10 mm 14 Pieces 10 Hex Bolt M10 x 200 mm 8 Pieces 11 Lock Washer M10 mm 14 Pieces 12 Hex Bolt M10 x 75 mm 4 Pieces 13 Washer M8 mm 2 Pieces...

Страница 5: ...te Openers Page 21 P2 Setting Master Slave Gate Page 21 P3 Setting the Master Slave Open Interval Page 22 P4 Setting the Master Slave Close Interval Page 22 P5 Blocking Force for Gate Opener 1 Page 23...

Страница 6: ...ing the Limit Switch Page 29 EMERGENCY Release Page 30 Using the Remote Control from the Car Page 30 Changing the Battery in the Remote Control Page 31 Checking the Reversion Page 31 Maintenance and C...

Страница 7: ...ve the local safety regulations to prevent accidents Westfalia assumes no liability for improper installation of the swing gate opener Do not modify the swing gate opener in any way Electrical install...

Страница 8: ...and there are no obstructions persons or animals Keep persons or ani mals out of reach of the gate as long as the gate is not complete ly opened or closed Please mind the danger area There is risk of...

Страница 9: ...Keep the swing gate bottom and the ground clean and free of snow ice stones etc Only use original spare parts original accessory and mounting material Should the swing gate opener becomes damaged do...

Страница 10: ...m The structure of the gate has to be rigid iron metal wood The swing gate system must be in good mechanical and trouble free condition and should not be damaged or has signs of wear It must be possi...

Страница 11: ...ing to the control box The gate cannot be easily opened without damaging the gate opener or the hinges of the gate system The accessory marked with is not available at Westfalia The power cable from t...

Страница 12: ...side of the gate and gate opener 2 is mounted at the left side of the opener view from in side of the property see picture on page 7 The gate opener must be mounted that way so the opening of the emer...

Страница 13: ...t is set in cement in order to ensure stability When mounting on stone or concrete posts use dowels that cannot slacken Preferably use compound anchors better than standard steel and PVC expansion dow...

Страница 14: ...ten the hex nut but do not over tighten 3 Mount the gate opener 1 with the already assembled bracket assy post pivot bracket and post bracket and use the clevis pin 20 and the hairpin clip 19 in order...

Страница 15: ...n this manual are intended for Pull to Open gate installation That means the gate will be opened by retracting the gate opener rod Therefore the gate opener must be installed from inside of the proper...

Страница 16: ...tion of the mounting material resp the gate opener The distances A B must not exceed 42 cm The distance A must be at least 8 cm or longer Example If distance A is 20 cm the distance B may not exceed 2...

Страница 17: ...Mounting 13...

Страница 18: ...e extended The moving rod should always be lubri cated sufficiently Make sure the moving rod does not become dirty or dusty Determine the distances A B 2 Adjust the moving rod and insert the triangula...

Страница 19: ...tended Gate is OPENED Moving Rod is retracted Driveway Make sure the minimum distance between gate and gate opener is 2 5 cm This distance must be maintained in the gate closed position and the gate o...

Страница 20: ...be cut with the hacksaw Cover the gate opener while drilling Please note that dust and swarf might damage the gate opener Use the included screws or other suitable screws and dowels for the resp surfa...

Страница 21: ...Mounting 17 8 19 Post Opener Bracket Assy 19 Gate is OPENED Now securely tighten all bolts and nuts The assembly is finished...

Страница 22: ...sert the power cable of the gate opener from below into the control box Pull enough cable and tighten the lock nuts of the strain relief The cables are labelled with small flags Please observe the fla...

Страница 23: ...ecting the control box to power mains Neutral to contact 3 Phase to contact 1 The numbers for the resp terminals are shown on the transparent cover Opener 1 Opener 2 Red Blue Black Green Yellow Red Bl...

Страница 24: ...d to power mains the display starts flashing and shows Now the unit is in standby mode 2 Hold the button FUNC pressed for more than 4 seconds The display shows P1 The unit is in setting mode for opera...

Страница 25: ...rt settings Setting 11 indicates operating mode for both gate openers factory setting 4 For storing press FUNC The display shows P2 P2 Setting Master Slave Gate The display shows P2 The unit is in Mas...

Страница 26: ...s before the Slave gate etc Factory setting is 3 sec Max 9 seconds are adjustable 2 For storing press FUNC The display shows P4 The unit is now in the mode Master Slave Close Interval P4 Setting the M...

Страница 27: ...ious injury to persons or damages to vehicles Too much force on the gate will interfere with the proper operation of the safety reversal system Do not increase the force beyond the minimum amount that...

Страница 28: ...retract the fully extended moving rod 385 mm If the limit switch B is positioned correctly the EMERGENCY Release is locked in place and the run time see setting mode PC for the gate opener is adjuste...

Страница 29: ...ory setting 60 sec Settings from 0 99 sec are possible 0 automatic closing time is deactivated That means the gate will stay open and will not close automatically The gate has to be closed by pressing...

Страница 30: ...p Time 15 seconds 30 seconds 3 seconds 12 seconds When the Soft Start Time is set at 3 seconds under mode Pb and the Total Run Time is 30 seconds the Fast Run Time has to be adjusted to 15 seconds in...

Страница 31: ...is in the setting mode for operating 1 resp 2 gate openers 3 Press FUNC several times until the display shows Pd Hold the button INC pressed for approx 2 seconds in order to set the program to factor...

Страница 32: ...eat the above mentioned steps Up to 6 remote controls can be programmed If you lose one remote control for safety reason please program all other remote controls to have a new code Erase all Remote Co...

Страница 33: ...gain and the gate will stop immediately When pressing the button on the remote control the gate will reverse direction and stop at the adjusted position Adjusting the Limit Switch Shut off power suppl...

Страница 34: ...be pushed too close to the limit switch A EMERGENCY Release In case of power cut off or system failure the gate opener can be manually unlocked By doing this the gate opener can be opened and closed b...

Страница 35: ...sion frequently Try to stop the gate As soon as the gate comes in contact with an obstruction the gate reverses and stops in the adjusted position Maintenance and Cleaning Lubricate the moving rod fro...

Страница 36: ...er Cable 150 900 cm Speed load dependent 16 mm sec Max Moving Rod Travel 385 mm Operating Temperature 22 C 55 C Protection Class IP44 Short Time Operation for Swing Gate Opener KB Time 4 Minutes Dimen...

Страница 37: ...xisting or separately purchased special accessory please note the connection diagram on the next page Make sure the special accessory is suitable for the gate opener The special accessories shown in t...

Страница 38: ...Connection Diagram for Accessory 34...

Страница 39: ...r Article No 85 27 06 is according to the basic requirements which are defined in the European Directives 1999 5 EC Radio and telecommunications terminal equipment R TTE 2011 65 EU Restriction of the...

Страница 40: ...nternet www westfalia net Kundenbetreuung Customer Services is Werter Kunde bitte helfen Sie mit Abfall zu vermeiden Sollten Sie sich einmal von diesem Artikel trennen wollen so bedenken Sie bitte das...

Отзывы: