3-4
NBB-1600-D20/D16 Series: Network Boot Bars - User's Guide
b)
Text Interface:
i.
Via Telnet:
Telnet to the default IP address (192.168.168.168).
The Plug Status Screen (Figure 3.2) should be displayed.
ii.
Via Local PC:
Start your communications program (e.g.,
Hyperterminal) and press
[Enter]
. The Plug Status Screen
should be displayed (Figure 3.2.) The default parameters for the
Console Port are 9600 bps, No Parity, 8 data bits, One stop bit.
iii.
Via Modem:
Use your communications program to dial the
number for the phone line connected to your external modem.
In order to communicate with the unit via modem, you must first
access the command mode via Network or Local PC, and use
the Serial Parameters Menu to set the Port Mode to "Modem."
2.
Test Switching Functions:
You may wish to perform the following
tests in order to make certain that the NBB is responding to commands.
a)
Reboot Outlet:
If you are communicating with the unit via the Web
Browser Interface, select the button in the "Boot" column for Plug 1,
and then click on "Apply." If you are operating the unit via the Text
interface, type
/BOOT 1
and press
[Enter]
. The status indicator
for Plug 1 should go off, pause for a moment, and then go back on,
indicating that the boot cycle has been successfully completed.
b)
Switch Outlet Off:
From the Web Browser Interface, select the
button in the "Off" column for Plug 1, and then click "Apply." From
the Text Interface, type
/OFF 1
and press
[Enter]
. The status
indicator for Plug 1 should go Off, indicating that the command has
been successfully completed. Leave Plug 1 in the "Off" state, and
then proceed to the next step.
c)
Switch Outlet On:
From the Web Browser Interface, select the
button in the "On" column for Plug 1, and then click "Apply."
From the Text Interface, type
/ON 1
and press
[Enter]
. The status
indicator for Plug 1 should then go back On, indicating that the
command has been successfully completed.
Содержание NBB-1600-D20, NBB-1600DE-D20, NBB-1600CE-D16
Страница 2: ......
Страница 12: ...2 4 NBB 1600 D20 D16 Series Network Boot Bars User s Guide...
Страница 18: ...3 6 NBB 1600 D20 D16 Series Network Boot Bars User s Guide...
Страница 22: ...4 4 NBB 1600 D20 D16 Series Network Boot Bars User s Guide...
Страница 57: ...Apx 1 A Interface Descriptions A 1 Console Port Interface Figure A 1 Console Port Interface...
Страница 63: ......
Страница 64: ...5 Sterling Irvine California 92618 949 586 9950 Toll Free 1 800 854 7226 Fax 949 583 9514 http www wti com...