background image

5-15

Confi guration

5.3.4. 

Network Parameters Menus

The Network Parameters Menus are used to select the IP Address and other 

network parameters.

• 

Web Browser Interface:

  Click the "Setup" button to access the Setup 

Menus, and then click the "Network Parameters" button.  The Network 

Parameters Menu will be displayed as shown in Figure 5.9.

• 

Text Interface:

  Type 

/N

 and press 

[Enter]

.  The Network Parameters 

Menu will be displayed as shown in Figure 5.10.

Notes:

•  Although the Web Browser Interface and Text Interface both allow 

configuration of the same network parameters, note that for the 

Text Interface, the IP Security feature is configured via a separate 

submenu.  For more information on IP Security, please refer to 

Section 5.3.4.1.

•  Settings for network parameters depend on the configuration of 

your individual network.  Contact your network administrator for 

appropriate settings.

The Network Parameters Menus allow the following parameters to be defined.  

Except where noted, all parameters listed here are available via both the Web 

Browser Interface and Text Interface.

• 

IP Address:

  Defines the IP address for the IPS unit.   

(Default = 192.168.168.168.)

• 

Subnet Mask:

  Defines the Subnet Mask for the IPS unit.   

(Default = 255.255.255.0.)

• 

Gateway Address:

  Defines the Gateway Address for the IPS unit.  

(Default = undefined.)

• 

Send MSS:

  Defines the Maximum Segment Size that will be sent by the 

IPS.  (Default = 536.)

• 

IP Security:

  Sets up the IP Security feature. Please refer to 

Section 5.3.4.1 for a detailed description of the IP Security feature.

• 

MAC Address:

  Displays the unit’s MAC Address.  Please note that this 

item only displays the assigned MAC Address, and cannot be used to 

redefine the address.  Note also that the MAC Address is not displayed via 

the Web Browser Interface.

Содержание IPS-800CE-D16, IPS-1600CE-D16

Страница 1: ...WTI Part No 13619 Rev A IPS 800CE D16 IPS 1600CE D16 InternetPowerSwitches User s Guide...

Страница 2: ......

Страница 3: ...tection and supply wiring GROUNDING Reliable earthing of this equipment must be maintained Particular attention should be given to supply connections when connecting to power strips rather than direct...

Страница 4: ...y 1989 on the approximation of the laws of Member States relating to electromagnetic compatibility and Council Directive 73 23 EEC of 19 February 1973 on the harmonization of the laws of Member States...

Страница 5: ...us 5 6 5 3 2 The Serial Parameters Menu 5 9 5 3 3 Plug Parameters Menus 5 11 5 3 3 1 Plug Passwords and Co Location Features 5 12 5 3 3 2 The Boot Sequence Delay Period 5 13 5 3 4 Network Parameters M...

Страница 6: ...Browser Interface 5 6 5 4 General Parameters Menu Text Interface 5 7 5 5 Serial Parameters Menu Web Browser Interface 5 9 5 6 Serial Parameters Menu Text Interface 5 9 5 7 Plug Parameters Menu Web Bro...

Страница 7: ...ity web browser access requires the user to enter an assigned user name and password The IPS provides two levels of operational passwords the System Administrator Level which allows access to all con...

Страница 8: ...features function identically except where noted Model Number Total Outlets Input Voltage Max Load per Outlet Max Load per Bus Max Load per Unit IPS 800CE D16 8 100 to 240 VAC 10 Amps 16 Amps 32 Amps...

Страница 9: ...reaker An IEC320 C20 AC inlet and 16 Amp Circuit Breaker which supply power to the Circuit B outlets Also includes cable keeper not shown Bus A Switched Outlets and Indicator Lights AC Outlets that ca...

Страница 10: ...he Default Button s manual plug control capabilities can also be disabled as described in Section 5 3 1 Unit Status Indicators Two LED Indicators which function as follows ON Lights when power is appl...

Страница 11: ...er rating nameplate on the IPS back panel and then connect the IPS unit to an appropriate power source Both the IPS 800CE D16 and the IPS 1600CE D16 should be connected to a 100 to 240 VAC power sourc...

Страница 12: ...3 2 Communicating with the IPS The IPS offers two separate user interfaces the Web Browser Interface and the Text Interface The Web Browser interface allows you to contact the IPS via a TCP IP networ...

Страница 13: ...nde ned ON 0 5 Secs ON 7 unde ned unde ned ON 0 5 Secs ON 8 unde ned unde ned ON 0 5 Secs ON H for help IPS Figure 3 2 Plug Status Screen Text Interface Model IPS 800CE D16 Shown b Text Interface i Vi...

Страница 14: ...uld go Off indicating that the command has been successfully completed Leave Plug 1 in the Off state and then proceed to the next step c Switch Outlet On From the Web Browser Interface select the butt...

Страница 15: ...power supply cables from being accidentally disconnected from the unit IPS 1600CE D16 The Sixteen plug unit includes pre installed cable keepers When attaching the power supply cables to the unit rst...

Страница 16: ...of the AC Outlets on the IPS unit Note that when power is applied to the IPS the AC Outlets will be switched ON by default Note that both the IPS 1600CE D16 and IPS 800CE D16 feature two separate pow...

Страница 17: ...net jack for connection to a TCP IP network Connect your 10Base T cable to the Network Port Note that the IPS includes a default IP address 192 168 168 168 and a default subnet mask 255 255 255 0 When...

Страница 18: ...4 4 IPS 800CE D16 IPS 1600CE D16 User s Guide...

Страница 19: ...is entered the System Mode will be active If a Plug Password is entered the User Mode will be active The System Password is de ned via the General Parameters menu Section 5 3 1 and the Plug Passwords...

Страница 20: ...ailable via network modem or local PC The sections that follow describe the procedure for accessing the Web Browser Interface or the Text Interface Note Con guration functions are only available when...

Страница 21: ...etwork The IPS must be connected to your TCP IP Network and your PC must include a communications program such as Hyperterminal Access Via Modem An external modem must be connected to the IPS RS232 CO...

Страница 22: ...he unit will display the Password Prompt Key in either the System Password or Plug Password and press Enter If the System Password has not been de ned the prompt will not be displayed when the unit is...

Страница 23: ...selected parameters will not be activated until you click the Apply button Click Switch Panel to return to the main status screen Text Interface Refer to the Help Screen H then enter the appropriate c...

Страница 24: ...you to de ne the following parameters System Password The IPS will display a password prompt when you attempt to access command mode When the System Password is entered at log on the System Mode will...

Страница 25: ...haracters asterisks or quotation marks Site ID De nes a brief text message which can describe the location of the IPS unit Up to 32 characters Default unde ned Notes The Site ID Message cannot begin w...

Страница 26: ...entering a password If security is a concern and the Automated Mode is required it is recommended to use the IP Security feature Section 5 3 4 1 to restrict access Manual Switch Button Enables and con...

Страница 27: ...cess the Setup Menus and then click the Serial Parameters button The Serial Parameters Menu will be displayed as shown in Figure 5 5 Text Interface Type C and press Enter The Serial Parameters Menu wi...

Страница 28: ...he serial COM RS232 Port for use with either a local PC or an external modem Note that when the Port Mode is set to Modem the modem initialization string will be sent every 15 minutes Default Console...

Страница 29: ...re n is the number or name of the plug you wish to con gure The Plug Parameters Menu will be displayed as shown in Figure 5 8 Note that in this case the major difference between the Web Browser Interf...

Страница 30: ...en the Default command D is invoked or after power to the unit has been interrupted and then restored After the default command is invoked or power is restored the IPS will automatically switch each p...

Страница 31: ...user is only allowed access to plugs one through four and that the Boot Sequence Delays for each plug have been set as follows Plug 1 1 Second Plug 2 2 Seconds Plug 3 5 Seconds Plug 4 1 Minute If the...

Страница 32: ...s Menu Web Browser Interface NETWORK PARAMETERS 1 IP Address 192 168 168 168 2 Subnet Mask 255 255 255 0 3 Gateway Address unde ned 4 Send MSS 536 5 IP Security MAC Address 00 09 9b 00 a0 32 Enter Sel...

Страница 33: ...e con guration of your individual network Contact your network administrator for appropriate settings The Network Parameters Menus allow the following parameters to be de ned Except where noted all pa...

Страница 34: ...long with the selected permit deny action for each mask a Each Security Mask prompt de nes a speci c IP address or range of addresses Each Mask Action prompt de nes the permit deny action for the corr...

Страница 35: ...only by addresses that begin with 192 deny access to 192 1 1 5 Security Mask 1 255 255 255 255 Mask 1 Action Deny Security Mask 2 192 255 255 255 Mask 2 Action Permit Security Mask 3 192 1 1 5 Mask 3...

Страница 36: ...e displayed as shown in Figure 5 13 The Telnet Parameters Menus allow the following parameters to be de ned Please note that all parameters listed here are available via both the Web Browser Interface...

Страница 37: ...then click the Web Server Parameters button The Web Server Parameters Menu will be displayed as shown in Figure 5 14 Text Interface Type W and press Enter The Web Server Parameters Menu will be displa...

Страница 38: ...ly de ned con guration As described in Section 7 this provides quick recovery in the event that the unit is accidentally reset to default parameters and also allows you to copy parameters to other IPS...

Страница 39: ...ce the rst screen that is displayed is the Plug Status Screen or Switch Panel The Plug Status Screen Figure 6 1 lists the current On Off status of the IPS s Switched Outlets and provides a series of r...

Страница 40: ...ick the Boot button in the All Plugs row and then Click Apply 6 Set Plugs to Power Up Defaults To set plugs to their user de ned Power Up Default On Off status click the Default button in the All Circ...

Страница 41: ...nt status of the IPS s Switched AC Outlets and displays the rmware version and currently de ned Site I D Message Normally the Plug Status Screen will also be redisplayed each time a command is success...

Страница 42: ...ter commands are successfully completed When switching and reboot operations are initiated Boot Sequence Delay times will be applied as described in Section 5 3 3 2 Internet Power Switch v1 41h Site I...

Страница 43: ...d plug Note that the BOOT command can also be entered as BO For example BOOT 1 or BO ATMSWTCH 4 Set Plugs to Power Up Defaults Type D and press Enter Plugs will be set to their default On Off status w...

Страница 44: ...the number for the plugs that mark the beginning and end of the series separated by a colon For example to switch plugs 1 through 3 On enter the following ON 1 3 Enter 4 All Plugs To apply a command t...

Страница 45: ...e is enabled all IPS password security functions are disabled and users are able to access System Level command functions including the con guration menus and control plugs without entering a password...

Страница 46: ...using invalid formats or arguments All other status display and con guration commands will still function as normal 6 5 Manual Operation In addition to the command driven functions available via the W...

Страница 47: ...etc which allows downloading of ASCII les Note Although this function is only available via the Text Interface parameters that are de ned via the Web Browser Interface will also be sent to the ASCII...

Страница 48: ...Con gure your communications program to upload an ASCII text le 4 Upload the le with the saved parameters If necessary key in the le name and directory path 5 When the upload is complete make certain...

Страница 49: ...ore beginning this upgrade procedure 1 Obtain the update le Firmware modi cations can either be mailed to the customer on a CDR or downloaded from WTI Place the upgrade CDR in your disk drive or copy...

Страница 50: ...Incomplete Upload If the upload is interrupted times out or if the update le becomes corrupted during transfer the IPS will display a screen which asks for con rmation before proceeding To proceed typ...

Страница 51: ...Apx 1 A Interface Description A 1 Serial COM RS232 Port Interface Figure A 1 COM Port Interface...

Страница 52: ...let 16 Amps per Circuit providing a Total of 32 Amps for both circuits Control Ports Ethernet Port 10Base T COM Port DB9M RS232C DTE RS232 Coding Serial ASCII 7 8 Bits Physical Environmental Size IPS...

Страница 53: ...odel of the unit its serial number and a description of its symptoms If the unit should need to be returned for factory repair it must be accompanied by a Return Authorization number from Customer Ser...

Страница 54: ...his publication are trademarks of their respective companies Information and descriptions contained herein are the property of Western Telematic Inc Such information and descriptions may not be copied...

Страница 55: ...nsole Port 2 2 4 2 Apx 1 Baud Rate 5 10 Data Bits 5 10 Parity 5 10 Stop Bits 5 10 Contact Information Apx 3 Customer Service Apx 3 D Data Bits 5 10 Default Button 2 2 5 8 Default Command 6 5 Default I...

Страница 56: ...RS232 Port 2 2 4 2 Apx 1 S Saving Parameters 5 20 7 1 Sectors 8 1 Security 5 16 Security Level 5 1 Send MSS 5 15 Serial Parameters 5 9 to 5 10 Serial Port Apx 1 Baud Rate 5 10 Data Bits 5 10 Parity 5...

Страница 57: ......

Страница 58: ...5 Sterling Irvine California 92618 949 586 9950 Toll Free 1 800 854 7226 Fax 949 583 9514 http www wti com...

Отзывы: