Safety

Read this manual and gather all available information on the product. Make sure you 
understand it fully before connecting the product to a power supply. Check that your 
application does not exceed the safe operating specifications for this product.

This symbol means that the product shall not be treated 
as unsorted municipal waste when disposing of it. It needs 
to be handed over to an applicable collection point for 
recycling electrical and electronic equipment. 

By ensuring this product is disposed of correctly, you will 
help to reduce hazardous substances and prevent potential 
negative consequences to both environment and human 
health, which could be caused by inappropriate disposal. 

Product disposal 

Care recommendations

Follow the care recommendations below to maintain full operation of the product and 
tofulfill the warranty obligations:
• Do not drop, knock or shake the product. Rough handling above the specification may 
cause damage to internal circuit boards.
• Use a dry or slightly water-damp cloth to clean the product. Do not use harsh 
chemicals, cleaning solvents or strong detergents.
• Do not paint the product. Paint can clog the product and prevent proper operation. 
If the product is used in a manner not according to specification, the protection provided 
by the equipment may be impaired.
If the product is not working properly, contact the place of purchase, nearest Westermo 
distributor office or Westermo technical support.

Содержание Wolverine DDW-142-12VDC-BP

Страница 1: ...www westermo com DDW 142 242 12VDC BP Industrial Ethernet Extender...

Страница 2: ...2 6642 22541...

Страница 3: ...and users of the Westermo products It includes information on safety and regulations a product description installation instructions and technical specifications Software tools Related software tools...

Страница 4: ...both environment and human health which could be caused by inappropriate disposal Product disposal Care recommendations Follow the care recommendations below to maintain full operation of the product...

Страница 5: ...al injuries and or damages to the product The following levels are used Warning Hazardous voltage The product must be installed by qualified service personnel and built in to an apparatus cabinet or s...

Страница 6: ...Replacing the internal fuse must only be performed by Westermo qualified personell Warning Reduce the risk of fire To reduce the risk of fire use only telecommunication line cords with a cable diamet...

Страница 7: ...uipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or...

Страница 8: ...1kHz sine 2700 6000 MHz Conducted RF immunity EN 61000 4 6 Power port 10 V 80 AM 1 kHz sine 0 15 80 MHz Ethernet ports 10 V 80 AM 1 kHz sine 0 15 80 MHz SHDSL ports 10 V 80 AM 1 kHz sine 0 15 80 MHz R...

Страница 9: ...hours MIL HDBK 217F2 GB 25 C Vibration IEC 60068 2 64 random Operating 5 20 Hz 2 m s 20 500 Hz 3 dB oct 3 axis 3 30 min Shock IEC 60068 2 27 Operating 6 ms 1000 m s 6 directions 3 shocks direction Bum...

Страница 10: ...d contains amazing serial connectivity capability from being able to simulate an old AT modem convert Modbus RTU to TCP or encapsulate serial data into an IP packet DDW 142 242 12VDC BP is incredibly...

Страница 11: ...onnection Detachable screw terminal Connector size 0 2 2 5 mm AWG 24 13 Connect the product using at least 18 AWG 0 75 mm wiring Shielded cable Not required External supply current capability for prop...

Страница 12: ...ected to this port The cable shield should be properly connected 360 to an earthing point within 1 m from this port This earthing point should have a low impedance connection to the conductive enclosu...

Страница 13: ...12 V Logic zero 1V Isolation to All other Connection Detachable screw terminal Connector size 0 2 2 5 mm AWG 24 13 SHDSL Electrical specification ITU T G 991 2 Annex B Data rate 32 kbit s to 30 4 Mbit...

Страница 14: ...To Send No 8 RTS In Request To Send Female Pin 1 Pin 8 Direction relative this product Ethernet connection TX 2 ports Position Direction Description No 1 In Out Transmitted Received data No 2 In Out T...

Страница 15: ...used to connect to the CLI Command Line Interface The following steps needs to be taken 1 Connect the serial diagnostic cable to the console port use only Westermo cable 1211 2027 2 Connect cable to y...

Страница 16: ...within the product see WeOS Management Guide An external load in series with an external voltage source is required for proper functionality For voltage current ratings see Interface Specification sec...

Страница 17: ...RED LNK SHDSL ports Link indicator Port 1 2 OFF No DSL link GREEN DSL link established GREEN FLASH DSL link negotiation YELLOW Port alarm and no link Or if FRNT or RSTP mode port is blocked SHDSL port...

Страница 18: ...nside an apparatus cabinet or similar It is recommended that the DIN rail is connected to ground Snap on mounting see figure Mounting the product with integrated DIN clip Removal Removing the product...

Страница 19: ...e use of the product in full operating temperature range and service life When this product is operated at an ambient temperature above 60 C 140 F forced ventilation is required to not exceed Touch Te...

Страница 20: ...uration of the product IPConfig tool This is a custom Westermo tool used for discovery of attached Westermo products Web Configuration of the product using the web browser CLI Configuration of the pro...

Страница 21: ...set and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet cable The ON LED will stop flashing This initiates the factory rese...

Страница 22: ...REV D 6642 22541 2020 06 Westermo Network Technologies AB Sweden Westermo SE 635 35 Stora Sundby Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com...

Отзывы: