Description

The TR-36B is a rack mount analogue V.34 PSTN and 2- or 4-wire leased line modem. 
It supports data rates of up to 115.2 kbit/s on the terminal side and modem modulation 
speeds of up to 33.6 kbit/s on the line side. The modem is designed to harsh industrial 
standards for applications where a number of modems are required in the same loca-
tion. The unit has passed extensive approvals testing by both Westermo and external test 
houses, showing the modem can operate in environments with a high level of electromag-
netic interference.

The TR-36B features a number of security functions such as password protection, dial-
back security and caller ID answering making the modem ideal for critical industrial appli-
cations. The TR-36B can also be remotely configured making it ideal for use in unmanned 
installations. 

The modem is designed to be prepared for unexpected faults. The modem is equipped 
with transient protection on the line side and a watchdog function that monitors and 
automatically resets the modem in the event of a fault. In case of a leased line failure, a 
PSTN dial backup facility can be configured for additional reliability.

The TR-36 is configurable via its serial interface using standard terminal emulation soft-
ware using Hayes AT commands or the Westermo TD-Tool modem configuration utility. 
Additionally many functions of the TR-36B can be configured via the onboard 
DIP-switches.

The modem is designed for use in the Westermo RV-07B 19" rack, which can hold up to 
16 cards as well as two PS-20 power supplies. The modems slide into the chassis from 
the front with all line connections terminating onto the backplane. The rack can hold up 
to 16 TR-36B modems and can also be externally powered by a 24 V supply.

… Data rate up to 33.6 kbit/s with 

Fast Connect

… Terminal rate up to 115.2 kbit/s

… 2- and 4-wire leased line

… V.23 HDX with multidrop

… DTR and incoming data dialling

… DIP-switch configuration

… Watchdog

… Secure call back and access

… Industrial environment transient 

protection on all interfaces

… Up to 11 bits

… Tri-Galvanic  isolation 

(interface/line/supply) 

… Caller ID presentation 

and answering

… Remote configuration

… RS-422 / RS-485 interface 

… Dial backup for PSTN 

and Leased Line 

Содержание TR-36B

Страница 1: ...Tele and leased line modem for RV 07 19 rack system www westermo com Westermo Teleindustri AB User Guide 6614 2210 TR 36B...

Страница 2: ...cular purpose are made in relation to the accuracy and reliability or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Unde...

Страница 3: ...azardous voltage may occur within this unit when connected to power supply or TNV circuits Care recommendations Follow the care recommendations below to maintain full operation of unit and to fulfil t...

Страница 4: ...on reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the rec...

Страница 5: ...owing EC directive s No Short name 2004 108 EC Electromagnetic Compatibility EMC 1999 5 EC Radio and telecommunications terminal equipment R TTE References of standards applied for this EC declaration...

Страница 6: ...th Mains freq 50 Hz SS 436 15 03 Signal ports 250 V 50 Hz line to line Voltage dips and interruption EN 61000 4 29 DC power ports 10 100 ms interruption 10 ms 30 reduction 10 ms 60 reduction 20 above...

Страница 7: ...ically resets the modem in the event of a fault In case of a leased line failure a PSTN dial backup facility can be configured for additional reliability The TR 36 is configurable via its serial inter...

Страница 8: ...OFF No data FLASH The modem transmitting data on the DTE interface TD OFF No data FLASH The modem receiving data on the DTE interface DCD OFF DCD signal is inactive ON DCD signal is active modem has d...

Страница 9: ...32 pin male connector LED Status Indicators Connections TR 36B TR 36B have 1 Europe connector angled 32 pin male The connector has Westermo specific pin out and is intended to be insert into RV 07B J...

Страница 10: ...Selection of DTE speed ON 1 2 3 4 5 6 7 8 300 bit s ON 1 2 3 4 5 6 7 8 9600 bit s ON 1 2 3 4 5 6 7 8 600 bit s ON 1 2 3 4 5 6 7 8 19 2 kbit s ON 1 2 3 4 5 6 7 8 1200 bit s ON 1 2 3 4 5 6 7 8 38 4 kbit...

Страница 11: ...h DTE interface Selection ON 1 2 3 4 5 6 7 8 RS 422 485 disable RS 232 enable ON 1 2 3 4 5 6 7 8 RS 422 485 enable RS 232 disable ON 1 2 3 4 5 6 7 8 7E 1S ON 1 2 3 4 5 6 7 8 7O 1S ON 1 2 3 4 5 6 7 8 8...

Страница 12: ...abled ON 1 2 3 4 5 6 7 8 Backup of leased line enabled S2 DIP switch Selection of answering calling mode for PSTN backed up Leased Line ON 1 2 3 4 5 6 7 8 Answering ON 1 2 3 4 5 6 7 8 Calling S2 DIP s...

Страница 13: ...32bis 4800 ON 1 2 3 4 5 6 7 8 V 34 33600 ON 1 2 3 4 5 6 7 8 Auto V 32 V32bis ON 1 2 3 4 5 6 7 8 Automatic line speed ON 1 2 3 4 5 6 7 8 V 32bis 9600 S3 DIP switch Flow control DTE interface ON 1 2 3...

Страница 14: ...8 Use stored values ON 1 2 3 4 5 6 7 8 DCD and DSR always on DTR ignored AT C0 D0 S0 S4 DIP switch Set modem to factory default ON 1 2 3 4 5 6 7 8 Use stored values ON 1 2 3 4 5 6 7 8 Restore factory...

Страница 15: ...5 6 7 8 S2 ON 1 2 3 4 5 6 7 8 S4 Factory settings S5 DIP switch RS 422 485 termination ON 1 2 3 4 No termination ON 1 2 3 4 Termination of R in 4 wire connection ON 1 2 3 4 Termination of both T and R...

Страница 16: ...ON 1 2 3 4 5 6 7 8 8E1 8O1 8O1 in command mode ON 1 2 3 4 5 6 7 8 7E1 7O1 8N1 8N1 in command mode S2 DIP switch Leased line 2 4 wire selection ON 1 2 3 4 5 6 7 8 2 wire leased line ON 1 2 3 4 5 6 7 8...

Страница 17: ...andard the receiver in multidrop systems at the end points shall be terminated S4 DIP switch Termination recomendations for TR 36B ON 1 2 3 4 5 6 7 8 PSTN ON 1 2 3 4 5 6 7 8 Multidrop V23 2 wire endun...

Страница 18: ...termination is combined with fail safe functionality The termination is used to prevent undefined states when the bus is in tri state condition Using 2 wire RS 485 both ends should be terminated Using...

Страница 19: ...is installed by sliding the card along the slot guides Ensure the card is the correct way up the handle will be at the bottom of the card Press firmly but carefully until full connection between the...

Страница 20: ...ermo Data Communications Ltd Talisman Business Centre Duncan Road Park Gate Southampton SO31 7GA Phone 44 0 1489 580 585 Fax 44 0 1489 580586 E Mail sales westermo co uk Westermo Data Communications G...

Отзывы: