background image

5

6614-2210

Declaration of Conformity

 
 

Westermo Teleindustri AB 

 

 
 
 

Declaration of conformity

 

 

Org.nr/

Postadress/Postal address

 

Tel.

 

Telefax

 

Postgiro

 

Bankgiro

 

Corp. identity number

 

Registered office 

S-640 40  Stora Sundby 

016-428000 

016-428001 

52 72 79-4 

5671-5550 

556361-2604 

Eskilstuna 

Sweden 

Int+46 16428000 

Int+46 16428001 

 

 

 

 

 

 
 

The manufacturer

 

Westermo Teleindustri AB 

 

SE-640 40 Stora Sundby, Sweden 

 

Herewith declares that the product(s) 

Type of product 

Model 

Art no 

Rack mounted Tele and Leased Line modem 

TR-36B 

3614-0510 

 

is in conformity with the following EC directive(s). 

No 

Short name  

2004/108/EC Electromagnetic 

Compatibility 

(EMC) 

1999/5/EC 

Radio and telecommunications terminal equipment (R&TTE) 

 

References of standards applied for this EC declaration of conformity. 

No Title 

 

Issue 

EN 61000-6-2 

Immunity for industrial environments 

2005 

EN 61000-6-4 

Emission standard for industrial environments.  

2007 

EN 50121-4 

Railway applications – Electromagnetic compatibility 
– Emission and Immunity of the signalling and 
telecommunications apparatus 

2006 

IEC 62236-4 

Railway signalling and telecommunications apparatus  2003 

EN 55024 

Information technology equipment – Immunity 

1998 
+ A1:2001 
+ A2:2003 

The last two digits of the year in which the CE marking was affixed: 

08 

 
 

 

 

Pierre Öberg 
R&D Manager 
14th October 2008 

 

Содержание TR-36B

Страница 1: ...Tele and leased line modem for RV 07 19 rack system www westermo com Westermo Teleindustri AB User Guide 6614 2210 TR 36B...

Страница 2: ...cular purpose are made in relation to the accuracy and reliability or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Unde...

Страница 3: ...azardous voltage may occur within this unit when connected to power supply or TNV circuits Care recommendations Follow the care recommendations below to maintain full operation of unit and to fulfil t...

Страница 4: ...on reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the rec...

Страница 5: ...owing EC directive s No Short name 2004 108 EC Electromagnetic Compatibility EMC 1999 5 EC Radio and telecommunications terminal equipment R TTE References of standards applied for this EC declaration...

Страница 6: ...th Mains freq 50 Hz SS 436 15 03 Signal ports 250 V 50 Hz line to line Voltage dips and interruption EN 61000 4 29 DC power ports 10 100 ms interruption 10 ms 30 reduction 10 ms 60 reduction 20 above...

Страница 7: ...ically resets the modem in the event of a fault In case of a leased line failure a PSTN dial backup facility can be configured for additional reliability The TR 36 is configurable via its serial inter...

Страница 8: ...OFF No data FLASH The modem transmitting data on the DTE interface TD OFF No data FLASH The modem receiving data on the DTE interface DCD OFF DCD signal is inactive ON DCD signal is active modem has d...

Страница 9: ...32 pin male connector LED Status Indicators Connections TR 36B TR 36B have 1 Europe connector angled 32 pin male The connector has Westermo specific pin out and is intended to be insert into RV 07B J...

Страница 10: ...Selection of DTE speed ON 1 2 3 4 5 6 7 8 300 bit s ON 1 2 3 4 5 6 7 8 9600 bit s ON 1 2 3 4 5 6 7 8 600 bit s ON 1 2 3 4 5 6 7 8 19 2 kbit s ON 1 2 3 4 5 6 7 8 1200 bit s ON 1 2 3 4 5 6 7 8 38 4 kbit...

Страница 11: ...h DTE interface Selection ON 1 2 3 4 5 6 7 8 RS 422 485 disable RS 232 enable ON 1 2 3 4 5 6 7 8 RS 422 485 enable RS 232 disable ON 1 2 3 4 5 6 7 8 7E 1S ON 1 2 3 4 5 6 7 8 7O 1S ON 1 2 3 4 5 6 7 8 8...

Страница 12: ...abled ON 1 2 3 4 5 6 7 8 Backup of leased line enabled S2 DIP switch Selection of answering calling mode for PSTN backed up Leased Line ON 1 2 3 4 5 6 7 8 Answering ON 1 2 3 4 5 6 7 8 Calling S2 DIP s...

Страница 13: ...32bis 4800 ON 1 2 3 4 5 6 7 8 V 34 33600 ON 1 2 3 4 5 6 7 8 Auto V 32 V32bis ON 1 2 3 4 5 6 7 8 Automatic line speed ON 1 2 3 4 5 6 7 8 V 32bis 9600 S3 DIP switch Flow control DTE interface ON 1 2 3...

Страница 14: ...8 Use stored values ON 1 2 3 4 5 6 7 8 DCD and DSR always on DTR ignored AT C0 D0 S0 S4 DIP switch Set modem to factory default ON 1 2 3 4 5 6 7 8 Use stored values ON 1 2 3 4 5 6 7 8 Restore factory...

Страница 15: ...5 6 7 8 S2 ON 1 2 3 4 5 6 7 8 S4 Factory settings S5 DIP switch RS 422 485 termination ON 1 2 3 4 No termination ON 1 2 3 4 Termination of R in 4 wire connection ON 1 2 3 4 Termination of both T and R...

Страница 16: ...ON 1 2 3 4 5 6 7 8 8E1 8O1 8O1 in command mode ON 1 2 3 4 5 6 7 8 7E1 7O1 8N1 8N1 in command mode S2 DIP switch Leased line 2 4 wire selection ON 1 2 3 4 5 6 7 8 2 wire leased line ON 1 2 3 4 5 6 7 8...

Страница 17: ...andard the receiver in multidrop systems at the end points shall be terminated S4 DIP switch Termination recomendations for TR 36B ON 1 2 3 4 5 6 7 8 PSTN ON 1 2 3 4 5 6 7 8 Multidrop V23 2 wire endun...

Страница 18: ...termination is combined with fail safe functionality The termination is used to prevent undefined states when the bus is in tri state condition Using 2 wire RS 485 both ends should be terminated Using...

Страница 19: ...is installed by sliding the card along the slot guides Ensure the card is the correct way up the handle will be at the bottom of the card Press firmly but carefully until full connection between the...

Страница 20: ...ermo Data Communications Ltd Talisman Business Centre Duncan Road Park Gate Southampton SO31 7GA Phone 44 0 1489 580 585 Fax 44 0 1489 580586 E Mail sales westermo co uk Westermo Data Communications G...

Отзывы: