Westermo TR-36B Скачать руководство пользователя страница 6

6

6614-2210

Type tests and environmental conditions, TR-36B

Electromagnetic Compatibility

Phenomena

Test

Description

Test levels

ESD

EN 61000-4-2

Enclosure contact 

± 6 kV

Enclosure air

± 8 kV

RF field AM modulated 

IEC 61000-4-3

Enclosure

20 V/m 80% AM (1 kHz), 80 – 2 700 MHz

Fast transient

EN 61000-4-4

Signal ports

± 2 kV

Power ports

± 2 kV

Surge

EN 61000-4-5

Signal ports 
unbalanced

± 2 kV line to earth, ± 2 kV line to line 

Signal ports balanced

± 2 kV line to earth, ± 1 kV line to line

Power ports

± 2 kV line to earth, ± 2 kV line to line

RF conducted

EN 61000-4-6

Signal ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Power ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Voltage dips and 
interruption

EN 61000-4-11

AC power ports

10 & 5 000 ms, interruption
10 & 500 ms, 30% reduction
100 & 1 000 ms, 60% reduction

Mains freq. 50 Hz

EN 61000-4-16

Signal ports

100 V 50 Hz line to earth

Mains freq. 50 Hz

SS 436 15 03

Signal ports

250 V 50 Hz line to line

Voltage dips and 
interruption 

EN 61000-4-29

DC power ports

10 & 100 ms, interruption
10 ms, 30% reduction
10 ms, 60% reduction
+20% above & –20% below rated voltage

Radiated emission 

EN 55022

Enclosure

Class A

FCC part 15

Class A

Conducted emission

EN 55022

AC power ports

Class B

FCC part 15

AC power ports

Class B

EN 55022

DC power ports

Class B

Dielectric strength

EN 60950

Signal port to other 
isolated ports

2 kVrms 50 Hz 1 min

Power port to other 
isolated ports

3 kVrms 50 Hz 1 min
2 kVrms 50 Hz 1 min (@ rated power <60 V)

Environmental

Temperature

Operating

-40 to +70ºC 

Storage & Transport

–40 to +70ºC 

Humidity

Operating

5 to 95% relative humidity.

Storage & Transport

5 to 95% relative humidity.

Altitude

Operating

2 000 m / 70 kPa

Reliability prediction 
(MTBF)

MIL C217F2

Operating

676000 h @ 25ºC 

Service life

Operating

10 year

Packaging

Dimension W x H x D

20 x 100 x 175 mm

Weight

0.14 kg

Degree of protection

IEC 529

Enclosure

IP 20 

Cooling

Convection

Mounting

RV07B 19” rack

Содержание TR-36B

Страница 1: ...Tele and leased line modem for RV 07 19 rack system www westermo com Westermo Teleindustri AB User Guide 6614 2210 TR 36B...

Страница 2: ...cular purpose are made in relation to the accuracy and reliability or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Unde...

Страница 3: ...azardous voltage may occur within this unit when connected to power supply or TNV circuits Care recommendations Follow the care recommendations below to maintain full operation of unit and to fulfil t...

Страница 4: ...on reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the rec...

Страница 5: ...owing EC directive s No Short name 2004 108 EC Electromagnetic Compatibility EMC 1999 5 EC Radio and telecommunications terminal equipment R TTE References of standards applied for this EC declaration...

Страница 6: ...th Mains freq 50 Hz SS 436 15 03 Signal ports 250 V 50 Hz line to line Voltage dips and interruption EN 61000 4 29 DC power ports 10 100 ms interruption 10 ms 30 reduction 10 ms 60 reduction 20 above...

Страница 7: ...ically resets the modem in the event of a fault In case of a leased line failure a PSTN dial backup facility can be configured for additional reliability The TR 36 is configurable via its serial inter...

Страница 8: ...OFF No data FLASH The modem transmitting data on the DTE interface TD OFF No data FLASH The modem receiving data on the DTE interface DCD OFF DCD signal is inactive ON DCD signal is active modem has d...

Страница 9: ...32 pin male connector LED Status Indicators Connections TR 36B TR 36B have 1 Europe connector angled 32 pin male The connector has Westermo specific pin out and is intended to be insert into RV 07B J...

Страница 10: ...Selection of DTE speed ON 1 2 3 4 5 6 7 8 300 bit s ON 1 2 3 4 5 6 7 8 9600 bit s ON 1 2 3 4 5 6 7 8 600 bit s ON 1 2 3 4 5 6 7 8 19 2 kbit s ON 1 2 3 4 5 6 7 8 1200 bit s ON 1 2 3 4 5 6 7 8 38 4 kbit...

Страница 11: ...h DTE interface Selection ON 1 2 3 4 5 6 7 8 RS 422 485 disable RS 232 enable ON 1 2 3 4 5 6 7 8 RS 422 485 enable RS 232 disable ON 1 2 3 4 5 6 7 8 7E 1S ON 1 2 3 4 5 6 7 8 7O 1S ON 1 2 3 4 5 6 7 8 8...

Страница 12: ...abled ON 1 2 3 4 5 6 7 8 Backup of leased line enabled S2 DIP switch Selection of answering calling mode for PSTN backed up Leased Line ON 1 2 3 4 5 6 7 8 Answering ON 1 2 3 4 5 6 7 8 Calling S2 DIP s...

Страница 13: ...32bis 4800 ON 1 2 3 4 5 6 7 8 V 34 33600 ON 1 2 3 4 5 6 7 8 Auto V 32 V32bis ON 1 2 3 4 5 6 7 8 Automatic line speed ON 1 2 3 4 5 6 7 8 V 32bis 9600 S3 DIP switch Flow control DTE interface ON 1 2 3...

Страница 14: ...8 Use stored values ON 1 2 3 4 5 6 7 8 DCD and DSR always on DTR ignored AT C0 D0 S0 S4 DIP switch Set modem to factory default ON 1 2 3 4 5 6 7 8 Use stored values ON 1 2 3 4 5 6 7 8 Restore factory...

Страница 15: ...5 6 7 8 S2 ON 1 2 3 4 5 6 7 8 S4 Factory settings S5 DIP switch RS 422 485 termination ON 1 2 3 4 No termination ON 1 2 3 4 Termination of R in 4 wire connection ON 1 2 3 4 Termination of both T and R...

Страница 16: ...ON 1 2 3 4 5 6 7 8 8E1 8O1 8O1 in command mode ON 1 2 3 4 5 6 7 8 7E1 7O1 8N1 8N1 in command mode S2 DIP switch Leased line 2 4 wire selection ON 1 2 3 4 5 6 7 8 2 wire leased line ON 1 2 3 4 5 6 7 8...

Страница 17: ...andard the receiver in multidrop systems at the end points shall be terminated S4 DIP switch Termination recomendations for TR 36B ON 1 2 3 4 5 6 7 8 PSTN ON 1 2 3 4 5 6 7 8 Multidrop V23 2 wire endun...

Страница 18: ...termination is combined with fail safe functionality The termination is used to prevent undefined states when the bus is in tri state condition Using 2 wire RS 485 both ends should be terminated Using...

Страница 19: ...is installed by sliding the card along the slot guides Ensure the card is the correct way up the handle will be at the bottom of the card Press firmly but carefully until full connection between the...

Страница 20: ...ermo Data Communications Ltd Talisman Business Centre Duncan Road Park Gate Southampton SO31 7GA Phone 44 0 1489 580 585 Fax 44 0 1489 580586 E Mail sales westermo co uk Westermo Data Communications G...