25
6179-2201
S6 – Wait Time before Blind Dialing or for Dial Tone
Sets the length of time, in seconds, that the modem will wait for dial tone when encoun-
tering a “W” dial modifier before returning NO DIAL TONE result code.
(EU models)
The modem always pauses for a minimum of 2 seconds, even if the value of S6 is less
than 2 seconds.
Range: 2–60 seconds
Default: 4
S7 – Wait Time for Carrier, Silence, or Dial Tone
S7operation is country dependent.
1. Sets the length of time, in seconds, that the modem will wait for carrier before hanging
up. The timer is started when the modem finishes dialing (originate), or 2 seconds after
going off-hook (answer). In originate mode, the timer is reset upon detection of answer
tone if allowed by country restrictions.
2. Sets the length of time, in seconds, that modem will wait for silence when encounter-
ing the @ dial modifier before continuing with the next dial string parameter.
Range: 1–255 seconds
Default: 50
S8 – Pause Time For Dial Delay
S8 sets the time, in seconds, that the modem must pause when the “,” dial modifier is
encountered in the dial string.
Range: 0–255 seconds
Default: 2
S9 – Carrier Detect Response Time
S9 is supported for backwards compatibility only. No value can be written. Responds with
default value.
Range: 6 tenths of a second
Default: 6
(0.6 second)