47
6193-5201
Alternate procedure
– Adjust 240U-E network settings using serial port
(assuming configuration PC is on existing network)
a)
Open terminal program with settings with data rate 19.2 kbit/s, 8 data bits,
1 stop bit and no parity.
b) Set dipswitch to SETUP
c)
Connect straight through serial cable to 240U-E and power up unit.
d) When prompted, strike the Enter key to abort automatic boot
e)
Set IP address of 240U-E to 192.168.0.200 with command bip 192.168.0.200
f)
Set netmask of 240U-E to 192.168.0.200 with command bnm 255.255.255.0
g)
Set gateway address of 240U-E to 192.168.0.1 with command bgw 192.168.0.1
h) Set dipswitch to RUN
i)
Reset 240U-E with reset command.
j)
Open configuration webpage with Internet Explorer at address
http://192.168.0.200/
When prompted for password, enter default username “user” and password “user”
Enter “Network”, and select Operating Mode as Access Point.
Select Device Mode as Bridge.
Change the IP address to 192.168.0.200
Enter a System Address (SSID) string
Select the Radio Encryption required, and enter the system keys.
Make a record of these Encryption keys and use these on all modules in
the system.
Set dipswitch to RUN
Save the changes and unit will restart with new settings.
Client 1 Configuration
Perform the same configuration steps as the Access Point configuration with the follow-
ing differences:
… set the Ethernet and Wireless IP addresses of RM-240 to 192.168.0.201
… set the Operating Mode to Client.
Ensure the same System Generator String is used and the same Radio Encryption meth-
od is selected.
Client 2 Configuration
… As above, however set the Ethernet and Wireless IP addresses as 192.168.0.202