background image

21

6641-22301

FX100 Mbit (Fibre)

Bi-di 

LC2

Bi-di LC20

SM-

LC80

SM-

LC40

SM-

LC20

MM-

LC2

Connector

LC

LC

LC

LC

LC

LC

Distance km*

2

20

80

40

20

2

Fibre type μm

Multi mode 

62.5/125 

and 

50/125 

Single mode 

9/125

Single  mode 

9/125

Single mode

9/125

Single mode

9/125

Multi mode

62.5/125 

and 

50/125

Wavelength nm

Connector 1

1550

1310

1310

1310

Tx 1310 
Rx 1550

Connector 2

Tx 1550
Rx 1310

Transceiver type

LC Small Form Factor Pluggable (SFP)

Laser class

Class 1, IEC 825-1 Accessible Emission Limit (AEL)

Gbit 

Bi-di 

LC10

Bi-di 

LC20

SM-

LC80

SM-

LC50

SM-

LC10

MM-

LC2

CX

Connector

LC

LC

LC

LC

LC

LC

RJ-45

Distance km*

10

20

80

50

10

2

100 m

Fibre type μm

Single-

mode 
9/125

Single-

mode 
9/125

Single-

mode 
9/125

Single-

mode 
9/125

Single-

mode 
9/125

Multi -
mode 

62.5/

125 

and 

50/125

Wavelength nm

Connector 1

1550

1550

1310

1310

Tx 1310
Rx 1550

Connector 2

Tx 1550
Rx 1310

Transceiver type

LC Small Form Factor Pluggable (SFP)

Laser class

Class 1, IEC 825-1 Accessible Emission Limit (AEL)

*  Other distances also available, please contact Westermo

Содержание RedFox Series

Страница 1: ...ermo Teleindustri AB User Guide 6641 22301 RedFox S E R I E S 1 10 100 Base TX 5 6 7 8 2 3 4 1 1000 Base X 2 3 4 FRNT DC1 DC2 COM COM ST1 ST2 ON DC1 DC2 1 2 POWER CONSOLE IO FRNT DC1 DC2 COM COM ST1 S...

Страница 2: ...ument or withdraw it at any time without prior notice Under no circumstances shall Westermo be responsible for any loss of data or income or any special incidental and consequential or indirect damage...

Страница 3: ...ort or any connected fibre although this unit is designed to meet the Class 1 Laser regulations Care recommendations Follow the care recommendations below to maintain full operation of unit and to ful...

Страница 4: ...nvironments EN 61000 6 4 Electromagnetic compatibility Emission for industrial environments EN 50121 4 Railway applications Electromagnetic compatibility Emission and immunity of the signalling and te...

Страница 5: ...omagnetic Compatibility EMC References of standards applied for this EC declaration of conformity No Title Issue EN 55024 EN 55024 A1 EN 55024 A2 Electromagnetic compatibility Immunity IT equipment 19...

Страница 6: ...50 Hz SS 436 15 03 Signal ports 250 V 50 Hz line to line Voltage dips and interruption EN 61000 4 29 DC power ports 10 100 ms interruption 10 ms 30 reduction 10 ms 60 reduction 20 above 20 below rated...

Страница 7: ...o the RedFox datasheet For Getting Started and management please refer to the RedFox management guide RedFox Industrial The listed RedFox have different combinations of interface modules on the power...

Страница 8: ...ds the earth connection for detailed ground connection information see section on Earth Connection 2 and 3 slot Rack Modules The slot on the left must be a power and CPU module Other slot may vary dep...

Страница 9: ...l interfaces Two RJ 45 connectors with support for Ethernet 100BaseTX a USB port for easy save load system configuration and a console port for management through serial cable Use SSH or the Westermo...

Страница 10: ...flow control Circuit type SELV Transmission range 15 m Isolation to All other except USB Galvanic connection to USB Connection 2 5 mm jack use Westermo cable 1211 2027 FRNT DC1 DC2 COM COM ST1 ST2 ON...

Страница 11: ...roperly connected 360 to an earthing point within 1 m from this port This earthing point should have a low impedance connection to the conductive enclosure of the apparatus cabinet or similar where th...

Страница 12: ...t TD 3 In Out RD 4 Not connected 5 Not connected 6 In Out RD 7 Not connected 8 Not connected Shield In Out Connected to protective earth Position Direction Description 1 Out VBUS 2 In Out D 3 In Out D...

Страница 13: ...cted GREEN Internal DC2 power ok RED Unit has no power on DC2 FRNT OFF FRNT not enabled GREEN FRNT running and ok switch configured as member RED FRNT error switch configured as member FLASH GREEN FRN...

Страница 14: ...cable Not required except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails Conductive housing Yes Number of ports 8 NOTE Railway install...

Страница 15: ...TD 2 In Out TD 3 In Out RD 4 Not connected 5 Not connected 6 In Out RD 7 Not connected 8 Not connected Direction relative this unit LED indicators Copper ports RFI IM 01 LED Status Description Copper...

Страница 16: ...m 74 6 mi For supported transceivers see section on SFP transceivers Interfaces F4G Rated current 300 mA 24 VDC with mounted transceivers Optical Electrical specification IEEE std 802 3 2005 Edition D...

Страница 17: ...t port Direction relative this unit 1 1000 Base X 2 3 4 LED indicators on interface module F4G LED Status Description Fibre ports 1 4 OFF No link GREEN Good link FLASH GREEN Data transmitted received...

Страница 18: ...installed in Railway applications assignalling and telecommunications apparatus and located closeto rails Conductive housing Yes Number of ports 4 NOTE Railway installation close to the rails To mini...

Страница 19: ...nt consumption calculation Current consumption values described for each module is the current consumption for that module only To calculate total consumption values for the used modules shall be adde...

Страница 20: ...LC2 1100 0132 FX SM LC20 1100 0133 FX SM LC40 1100 0134 FX SM LC80 1100 0148 CX RJ 45 copper Gigabit Gbit Westermo article number Description Needs optical attenuator 1100 0144 SX MM LC0 55 1100 0147...

Страница 21: ...Factor Pluggable SFP Laser class Class 1 IEC 825 1 Accessible Emission Limit AEL Gbit Bi di LC10 Bi di LC20 SM LC80 SM LC50 SM LC10 MM LC2 CX Connector LC LC LC LC LC LC RJ 45 Distance km 10 20 80 50...

Страница 22: ...POWER CONSOLE IO Wall mounting This unit can also be wall mounted see figure Earth connection For correct function the ground connection on the unit needs to be properly connected to a solid ground Se...

Страница 23: ...d and management please refer to the RedFox management guide found on the product CD or at the website www westermo com redfox Referring documents Type Description Document number Management Guide Red...

Страница 24: ...24 6641 22301...

Страница 25: ...25 6641 22301...

Страница 26: ...26 6641 22301...

Страница 27: ...27 6641 22301...

Страница 28: ...rmo se Westermo Data Communications Ltd Talisman Business Centre Duncan Road Park Gate Southampton SO31 7GA Phone 44 0 1489 580 585 Fax 44 0 1489 580586 E Mail sales westermo co uk Westermo Data Commu...

Отзывы: