background image

8

6650-2201

Functional description

 

Internal Electronics 

COM 
COM 

+VA  

O

V

+VB 

NO 

NC 

STATUS  

POWER  

LED’s 

 

O

V

O
C

RxD/TxD-P 

RxD/TxD-N 

SHIELD  

PROFIBUS DP  

CH 1 

SFP  

Fibre transceiver

TX
RX

Switches

OVP

Over Voltage  Protection

OCP

Over Current Protection

Converter PROFIBUS DP – optical fibre 

ODW-611 is a fibre optic modem that converts between electrical PROFIBUS DP and
fibre optical link.

Data rate up to 12 Mbit/s 

ODW-611 converts PROFIBUS DP data in data rate from 9600 bit/s up to 12 Mbit/s.
Retiming of the PROFIBUS DP data ensures that the correct signal format is transmitted
from the ODW-611 converter.

Automatic data rate detection

The PROFIBUS data rate is set automatically as soon as ODW-611 has identified a cor-
rect data frame, independently of whether data is received from PROFIBUS DP or the
fibre optical link. Detected data rate remains until a number of consecutive faulty
received frames or after a delay without any received frame.This is set by switches, with
default setting of one faulty frame or 65 535 t

Bit

.

Point to point communication via fibre optical network

The electrical PROFIBUS DP network is transferred via a fibre optical network by the
use of two ODW-611 units.This application is useful e.g. for long distance communica-
tion, where electromagnetic interferences may occur or when isolation of the electrical
network is needed.

The maximum optical fibre distance depends on selected fibre transceiver and fibre type.
Distance up to 80 km (50 miles).

Point to point communication, fibre optical connection

POWER

CH 1

COM +VA +VB COM

POWER

CH 1

COM +VA +VB COM

TX

RX

TX

RX

Содержание ODW-611

Страница 1: ...Industrial Converter PROFIBUS DP to Fibre Optic Link Point to Point applications www westermo com Westermo Teleindustri AB 2005 User Guide 6650 2201 ODW 611 Fibre Optic Modem...

Страница 2: ...cular purpose are made in relation to the accuracy and reliability or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Unde...

Страница 3: ...ort or any connected fibre although this unit is designed to meet the Class 1 Laser regulations Care recommendations Follow the care recommendations below to maintain full operation of unit and to ful...

Страница 4: ...nce No maintenance is required as long as the unit is used as intended within the specified conditions Agency approvals and standards compliance FCC Part 15 105 Notice This equipment has been tested a...

Страница 5: ...50 0120 3650 0130 6650 2221 Industrial Converter RS 232 to fibre optic link ODW 622 3650 0601 3650 0610 3650 0620 3650 0630 6650 2231 ODW 631 3650 0201 3650 0210 3650 0220 3650 0230 6650 2221 Industri...

Страница 6: ...0 Hz EN 61000 4 16 Signal ports 100 V 50 Hz line to earth Mains freq 50 Hz SS 436 15 03 Signal ports 250 V 50 Hz line to line Voltage dips EN 61000 4 29 DC power ports 10 100 ms interruption and inter...

Страница 7: ...way installations The PROFIBUS data rate is set automatically as soon as ODW 611 has identified a correct data frame Retiming ensures the correct PROFIBUS DP signal format 9 position D sub PROFIBUS DP...

Страница 8: ...611 has identified a cor rect data frame independently of whether data is received from PROFIBUS DP or the fibre optical link Detected data rate remains until a number of consecutive faulty received...

Страница 9: ...tage SELV It is designed to operate permanently over a wide input range and provided with two independent inputs for enhanced redundancy if either supply fails 9 position D sub PROFIBUS DP connector T...

Страница 10: ...Bit 1 0 s Signal processing fibre to electrical max 0 3 s 0 3 s Overall system delay one way From received 5 s km 5 s km PROFIBUS DP data at one unit until 1 0 s 1 tBit 1 0 s 5 tBit transmitted data a...

Страница 11: ...ion to PROFIBUS DP and Status port Connection Detachable screw terminal Connector size 0 2 2 5 mm2 AWG 24 12 Power Interface specifications Port type Signal relay changeover contacts Rated voltage Up...

Страница 12: ...cal power Maximum min min min min Bit error rate BER 1 x 10 10 1 x 10 10 1 x 10 10 2 5 x 10 10 Transceiver type Small Form Factor Pluggable SFP Multi Sourcing Agreement MSA compliant Laser class Class...

Страница 13: ...ibre for details see page 12 Power screw terminal Connections Status screw terminal 3 position Direction Description No 1 NO Contact with C when link is in operation No 2 C Common No 3 NC Open no cont...

Страница 14: ...PR Flash Receive data on the electrical PROFIBUS DP port Data will be transmitted to the fibre link if it is a correct PROFIBUS DP frame OFF FR Flash Receive data on the Fibre Link This frame is trans...

Страница 15: ...5 tBit interruption in receiving frames until inactive BA2 3 ON 1 2 3 4 5 6 7 8 2 consecutive faulty frames until inactive BA1 ON 1 2 3 4 5 6 7 8 3 consecutive faulty frames until inactive BA1 ON 1 2...

Страница 16: ...Spacing is recommended for the use of unit in full operating temperature range and service life Removal Press down the black support at the top of the unit See figure Mounting This unit should be moun...

Страница 17: ...to point application is up and running Hints If the distance is long it may be necessary to adjust the bus parameter Slot time the monitoring time tBit of the sender of frame for acknowledgement of r...

Страница 18: ......

Страница 19: ......

Страница 20: ...89 Oslo Norway Phone 47 22 09 03 03 Fax 47 22 09 03 10 E mail contact ontimenet com Westermo Data Communications Ltd Talisman Business Centre Duncan Road Park Gate Southampton SO31 7GA Phone 44 0 1489...

Отзывы: