![Westermo MRI-120-F4G-PSE Series Скачать руководство пользователя страница 69](http://html.mh-extra.com/html/westermo/mri-120-f4g-pse-series/mri-120-f4g-pse-series_user-manual_960516069.webp)
65
Syntax
poe powering-mode 802.3af/forced
Parameters
802.3af: deliver power if and only if the attached
PD comply with IEEE 802.3af
forced: deliver power no maater what PD attached
Command Mode
Interface mode
Description
Set the Powring mode of PoE
Examples
EX 1:
Set 802.3af powring mode
Switch(config)# poe powering-mode 802.3af
EX 2:
Set forced powering mode
Switch(config)# poe powering-mode forced
Syntax
poe powering-mode 802.3at 2-event/lldp
Parameters
2-event: deliver power if and only if the attached
PD comply with IEEE 802.3at physical layer
classification
lldp: deliver power if and only if the attached
PD comply with IEEE 802.3at data link layer
classification
Command Mode
Interface mode
Description
Set the Powring mode of PoE
Examples
EX 1:
Set 802.3at 2-event powring mode
Switch(config)# poe powering-mode 802.3at
2-event
EX 2:
Set 802.3at lldpforced powering mode
Switch(config)# poe powering-mode 802.3at lldp
Syntax
poe control-mode user/schedule
Parameters
user: user mode
schedule: schedule mode
Command Mode
Interface mode
Description
Set the control mode of port
Examples
Set PoE port 2 to user mode.
EX 1:
Switch(config)# interface fa2
Switch(config-if)# poe control-mode user
Set PoE port 2 to schedule mode.
EX 2:
Switch(config-if)# poe control-mode schedule
Proudly Distributed by Gross Automation | (877) 268-3700