background image

5

6643-2210

Declaration of Conformity

 
 

Westermo Teleindustri AB 

 

 

Declaration of conformity

 

 

 Org.nr/

Postadress/Postal address

 

Tel.

Telefax

Postgiro

Bankgiro

Corp. identity number

 

Registered o

S-640 40  Stora Sundby 

016-428000 

016-428001 

52 72 79-4 

5671-5550 

556361-2604 

Eskilstuna

Sweden Int+46 

16428000 

Int+46 

16428001 

 

 

 

 

 

 
 

The manufacturer

 

Westermo Teleindustri AB 

 

SE-640 40 Stora Sundby, Sweden 

 

Type of product 

Model 

Art no 

Ethernet switch 

L+210-series switches 

3643-0100 

 

is in conformity with the following EC directive(s). 

No 

Short name  

2004/108/EC 

Electromagnetic Compatibility (EMC) 

 

References of standards applied for this EC declaration of conformity. 

No Title 

 

Issue 

EN 50121-4 

Railway applications – Electromagnetic compatibility 
– Emission and immunity of the signalling and 
telecommunications apparatus 

2006 

EN 55022 

Information technology equipment - Emission 

2006 
+A1:2007 

EN 55024 

Information technology equipment - Immunity 

1998 
+A1:2001 
+A2:2003 

EN 61000-6-1 

Electromagnetic compatibility – Immunity for 
residential environments 

2007 

EN 61000-6-2 

Electromagnetic compatibility – Immunity for 
industrial environments 

2005 

EN 61000-6-4 

Electromagnetic compatibility – Emission for 
industrial environments 

2007 

The last two digits of the year in which the CE marking was affixed: 

10 

 
 

 

 

Pierre Öberg 
Technical Manager 
3 May 2010 

 

Содержание Lynx Plus

Страница 1: ...Westermo Teleindustri AB www westermo com User Guide 6643 2210 Industrial Ethernet 10 port Switch Lynx...

Страница 2: ...warranties of any kind either express or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose are made in relation to the accuracy and re...

Страница 3: ...and to fulfil the warranty obligations This unit must not be operating with removed covers or lids Do not attempt to disassemble the unit There are no user serviceable parts inside Do not drop knock o...

Страница 4: ...vironments EN 61000 6 2 Immunity industrial environments EN 61000 6 4 Emission industrial environments EN 55022 A1 Emission IT equipment EN 55024 Immunity IT equipment FCC part 15 Class A EN 50121 4 R...

Страница 5: ...tic Compatibility EMC References of standards applied for this EC declaration of conformity No Title Issue EN 50121 4 Railway applications Electromagnetic compatibility Emission and immunity of the si...

Страница 6: ...Radiated RF emission EN 55022 Enclosure Class A FCC Part 15 Class A Conducted RF emission EN 55022 Power port Class B Signal ports Class B Dielectric strength EN 60950 1 Power port to all other ports...

Страница 7: ...ironments and places with heavy electrical interference require the use of a reliable media Lynx provides a number of solutions using fibre optic trans ceivers Multi or singlemode transceivers can be...

Страница 8: ...smission range Up to 150 m with CAT5e cable or better Isolation to All other Connection RJ 45 auto MDI MDI X Shielded cable Not required except when installed in Railway applications as signalling and...

Страница 9: ...G 24 12 Console Electrical specification TTL level Data rate 115 2 kbit s Data format 8 data bits no parity 1 stop bit no flow control Circuit type SELV Isolation to All other Connection 2 5 mm jack u...

Страница 10: ...see page 11 SFP transceivers for details see page 9 I O connection for details see page 11 Console port for details see page 9 Cable 1211 2027 Connection to console port The console port can be used t...

Страница 11: ...us Output Alarm relay status contact No 2 Status Output Alarm relay status contact No 3 Digital in Input Digital in No 4 Digital in Input Digital in The Status output is a potential free opto isolated...

Страница 12: ...OK on DC1 RED Power failure on DC1 DC2 OFF Unit has no power GREEN Power OK on DC2 RED Power failure on DC2 FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT Error BLINK Unit configured as FRNT Focal Poin...

Страница 13: ...This unit uses convection cooling To avoid obstructing the airflow around the unit use the following spacing rules Minimum spacing 25 mm 1 0 inch above below and 10 mm 0 4 inches left right the unit...

Страница 14: ...the WeOS management guide Factory default IP address 192 168 2 200 Netmask 255 255 255 0 Gateway Disabled Note If you are not sure about the subnet consult your network administrator Configuration Con...

Страница 15: ...he choice to go ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet c...

Страница 16: ...mo se Westermo Data Communications Ltd Talisman Business Centre Duncan Road Park Gate Southampton SO31 7GA Phone 44 0 1489 580 585 Fax 44 0 1489 580586 E Mail sales westermo co uk Westermo Data Commun...

Отзывы: