6
6643-2210
Type tests and environmental conditions
Environmental phenomena
Basic standard
Description
Test levels
ESD
EN 61000-4-2
Enclosure
Contact: ±6 kV
Air: ±8 kV
Fast transients
EN 61000-4-4
Power port
±2 kV
Signal ports
±2 kV
Earth port
±1 kV
Surge
EN 61000-4-5
Power port
L-E: ±0.5 kV, 12
Ω
, 9 μF
L-L: ±0.5 kV, 2
Ω
, 18 μF
L-E: ±2 kV, 42
Ω
, 0.5 μF
L-L: ±2 kV, 42
Ω
, 0.5 μF
L-E: ±2 kV, 12
Ω
, 9 μF
L-L: ±1 kV, 12
Ω
, 9 μF
Signal ports
L-E: ±1 kV, 2
Ω
L-E: ±2 kV, 42
Ω
, 0.5 μF
Power frequency magnetic field
EN 61000-4-8
Enclosure
300 A/m; 0, 16.7, 50 Hz
Pulsed magnetic field
EN 61000-4-9
Enclosure
300 A/m
Radiated RF immunity
EN 61000-4-3
Enclosure
10 V/m @ (80 – 800) MHz
20 V/m @ (800 – 1000) MHz
10 V/m @ (1400 – 2100) MHz
5 V/m @ (2100 – 2500) MHz
1 V/m @ (2500 – 2700) MHz
1 kHz sine, 80% AM
Conducted RF immunity
EN 61000-4-6
Power port
10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Signal ports
10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Earth port
10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Radiated RF emission
EN 55022
Enclosure
Class A
FCC Part 15
Class A
Conducted RF emission
EN 55022
Power port
Class B
Signal ports
Class B
Dielectric strength
EN 60950-1
Power port to all
other ports
1.5 kVrms, 50 Hz, 1 min
Signal ports to all
other ports
1.5 kVrms, 50 Hz, 1 min
Environmental
Temperature
Operating
–40 to +70 °C
Storage and transport –50 to +85 °C
Humidity
Operating
5 to 95 % relative humidity
Storage and transport 5 to 95 % relative humidity
Altitude
Operating
2 000 m / 70 kPa
Service life
Operating
10 year
Vibration
IEC 60068-2-6
(sine)
Operating
3 – 13.2 Hz: 1mm
13.2 – 100 Hz: 0.7 g
5.5 – 30 Hz: 1.5 g
30 – 50 Hz: 0.42 mm
50 – 500 Hz: 4.2 g*
IEC 60068-64
(random)
Operating
5 – 20 Hz: 2 m
2
/s
3
20 – 2000 Hz: –3 dB/oct
Shock
IEC 60068-2-27
Operating
30 g, 11 ms
100 g, 6 ms*
Bump
IEC 60068-2-27
Operating
10 g, 11 ms
Packaging
Enclosure
EN 60950-1
Zinc
Fire enclosure
Dimension W x H x D
With connectors
52.5 x 100 x 101 mm
52.5 x 119 x 101 mm
Weight
0.7 kg
Degree of protection
EN 60529
Enclosure
IP 40
Cooling
Convection
* Might require Ethernet cables to be fastened close to the unit.