background image

©

W

estermo T

eleindustri 

AB

www.westermo.com

User Guide

6643-2210

Industrial Ethernet

10-port Switch

Lynx

+

Содержание Lynx Plus

Страница 1: ...Westermo Teleindustri AB www westermo com User Guide 6643 2210 Industrial Ethernet 10 port Switch Lynx...

Страница 2: ...warranties of any kind either express or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose are made in relation to the accuracy and re...

Страница 3: ...and to fulfil the warranty obligations This unit must not be operating with removed covers or lids Do not attempt to disassemble the unit There are no user serviceable parts inside Do not drop knock o...

Страница 4: ...vironments EN 61000 6 2 Immunity industrial environments EN 61000 6 4 Emission industrial environments EN 55022 A1 Emission IT equipment EN 55024 Immunity IT equipment FCC part 15 Class A EN 50121 4 R...

Страница 5: ...tic Compatibility EMC References of standards applied for this EC declaration of conformity No Title Issue EN 50121 4 Railway applications Electromagnetic compatibility Emission and immunity of the si...

Страница 6: ...Radiated RF emission EN 55022 Enclosure Class A FCC Part 15 Class A Conducted RF emission EN 55022 Power port Class B Signal ports Class B Dielectric strength EN 60950 1 Power port to all other ports...

Страница 7: ...ironments and places with heavy electrical interference require the use of a reliable media Lynx provides a number of solutions using fibre optic trans ceivers Multi or singlemode transceivers can be...

Страница 8: ...smission range Up to 150 m with CAT5e cable or better Isolation to All other Connection RJ 45 auto MDI MDI X Shielded cable Not required except when installed in Railway applications as signalling and...

Страница 9: ...G 24 12 Console Electrical specification TTL level Data rate 115 2 kbit s Data format 8 data bits no parity 1 stop bit no flow control Circuit type SELV Isolation to All other Connection 2 5 mm jack u...

Страница 10: ...see page 11 SFP transceivers for details see page 9 I O connection for details see page 11 Console port for details see page 9 Cable 1211 2027 Connection to console port The console port can be used t...

Страница 11: ...us Output Alarm relay status contact No 2 Status Output Alarm relay status contact No 3 Digital in Input Digital in No 4 Digital in Input Digital in The Status output is a potential free opto isolated...

Страница 12: ...OK on DC1 RED Power failure on DC1 DC2 OFF Unit has no power GREEN Power OK on DC2 RED Power failure on DC2 FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT Error BLINK Unit configured as FRNT Focal Poin...

Страница 13: ...This unit uses convection cooling To avoid obstructing the airflow around the unit use the following spacing rules Minimum spacing 25 mm 1 0 inch above below and 10 mm 0 4 inches left right the unit...

Страница 14: ...the WeOS management guide Factory default IP address 192 168 2 200 Netmask 255 255 255 0 Gateway Disabled Note If you are not sure about the subnet consult your network administrator Configuration Con...

Страница 15: ...he choice to go ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet c...

Страница 16: ...mo se Westermo Data Communications Ltd Talisman Business Centre Duncan Road Park Gate Southampton SO31 7GA Phone 44 0 1489 580 585 Fax 44 0 1489 580586 E Mail sales westermo co uk Westermo Data Commun...