Factory default on L106-F2G and L206-F2G

It is possible to set the unit to factory default settings by using two straight standard 
Ethernet RJ-45 cables.
1.  Power off the switch and disconnect all Ethernet cables (copper and fibre).
2.  Connect one Ethernet cable between Ethernet ports 3 and 6, and the other between 

Ethernet ports 4 and 5. 
The ports need to be connected directly by an Ethernet cable, i.e., not via a hub or 
switch. Use a straight cable – not a cross-over cable – when connecting the ports.

3.  Power on the unit.
4. Wait for the unit to start up. Control that the ON LED is flashing red. 

The ON LED flashing indicates that the unit is now ready to be reset to factory 
default. You now have the choice to go ahead with the factory reset, or to skip factory 
reset and boot as normal.

  •   Go ahead with factory reset:   

Acknowledge that you wish to conduct the factory reset by unplugging the  
Ethernet cables. The ON LED will stop flashing.  
This initiates the factory reset process*, and the unit will restart with factory default 
settings. When the switch has booted up, the ON LED will show a green light, and is 
now ready to use.

  •   Skip the factory reset: 

To skip the factory reset process, just wait for approximately 30 seconds  
(after the ON LED starts flashing RED) without unplugging the Ethernet cables.   
The switch will conduct a normal boot with the existing settings.

*

  Note

  Do not power off the unit while the factory reset process is in progress.

Referring documents

Type

Description

Document number

Management Guide

Westermo OS management guide

6101-3201

Содержание Lynx L106-F2G

Страница 1: ...Westermo Teleindustri AB www westermo com User Guide 6643 2250 Industrial Ethernet 6 port Switch Lynx L106 F2G L206 F2G WeOS...

Страница 2: ...ty or contents of this document Westermo reserves the right to revise this document or withdraw it at any time without prior notice Under no circumstances shall Westermo be responsible for any loss of...

Страница 3: ...Surface of Equipment may exceed Touch Temperature Limit according to EN IEC UL 60950 1 To reduce the risk of fire use only No 26 AWG or larger telecommunication line cord Class 1 Laser Product Do not...

Страница 4: ...telecommunications apparatus Safety UL IEC EN 60950 1 IT equipment Marine DNV GL rules for classification Ships and offshore units FCC Part 15 105 Notice This equipment has been tested and found to c...

Страница 5: ...ty for industrial environments 2005 EN 61000 6 3 Electromagnetic compatibility Emission for residential environments 2007 A1 2011 EN 61000 6 4 Electromagnetic compatibility Emission for industrial env...

Страница 6: ...e Class A Class A Conducted RF emission CISPR 16 2 1 ANSI C63 4 FCC part 15 Power port Class B Signal ports Class B Dielectric strength EN 60950 1 Power port to all other ports 1 5 kVrms 50 Hz 1 min S...

Страница 7: ...ations in harsh environments and places with heavy electrical interference require the use of a reliable media Lynx provides a number of solutions using fibre optic transceivers Multi or singlemode tr...

Страница 8: ...t type TNV 1 Transmission range Up to 150 m with CAT5e cable or better Isolation to All other Connection RJ 45 auto MDI MDI X Shielded cable Not required except when installed in Railway applications...

Страница 9: ...onnector type A Console Electrical specification TTL level Data rate 115 2 kbit s Data format 8 data bits no parity 1 stop bit no flow control Circuit type SELV Connection 2 5 mm jack use only Westerm...

Страница 10: ...puter USB port if drivers are needed they can be downloaded from ourWeb page 3 Use a terminal emulator and connect with correct speed and format 115200 8N1 to the assigned port For more information ab...

Страница 11: ...o 1 Status Output Alarm relay status contact No 2 Status Output Alarm relay status contact No 3 Digital in Input Digital in No 4 Digital in Input Digital in The Status output is a potential free opto...

Страница 12: ...1 OFF Unit has no power GREEN Power OK on DC1 RED Power failure on DC1 DC2 OFF Unit has no power GREEN Power OK on DC2 RED Power failure on DC2 FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT Error BLIN...

Страница 13: ...ted DIN clip Removal Cooling This unit uses convection cooling To avoid obstructing the airflow around the unit use the following spacing rules Minimum spacing 25 mm 1 0 inch above below and 10 mm 0 4...

Страница 14: ...gement Tool in the WeOS management guide Factory default IP address 192 168 2 200 Netmask 255 255 255 0 Gateway Disabled Note If you are not sure about the subnet consult your network administrator Co...

Страница 15: ...tory default You now have the choice to go ahead with the factory reset or to skip factory reset and boot as normal Go ahead with factory reset Acknowledge that you wish to conduct the factory reset b...

Страница 16: ...r www westermo fr Germany info westermo de www westermo de North America info westermo com www westermo com Singapore sales westermo com sg www westermo com Sweden info sverige westermo se www westerm...

Отзывы: