Environmental
phenomena
Basic
standard
Description
Test levels
Temperatures
EN 60068-2-1
EN 60068-2-2
EN 60068-2-14
Operational
-40 to +70°C (-40 to +158°F)
a
Storage and
transport
-55 to +85°C (-67 to +185°F)
Humidity
EN 60068-2-30
EN 60068-2-78
Operational
5-95% relative humidity
93% RH, 96 hours
Storage and
transport
Device reliability
class
IEC 61850-3
Class 1: Temporary loss of communication
and/or communication errors can be
tolerated
IEEE 1613
Corrosive gases
IEC
60068-2-60
Operational
Method 3, 21 days
b
Altitude
Operational
2000 m/70 kPa
MTBF
MIL-HDBK
217F
506,000 hours
Telcordia
955,000 hours
Vibration
c
IEC 60068-2-6
(sine)
Operational
5 to 20 Hz, 1,3 mm
20 to 200 Hz, 1 g
20 sweep cycles in each axis, 1 octave/min
Class 2, 10 to 150 Hz at 2 g
20 sweep cycles in each axis, 1 octave/min
5 to 8 Hz at ± 7.5 mm
8 to 500 Hz at 2 g
5 sweep cycles in each axis (3 x 5), 1
octave/min
Non-operational,
resonance test
2 to 13.2 Hz at ± 1 mm
13.2 to 100 Hz at 1 g
1 sweep cycle in each axis, 1 octave/min
IEC
60068-2-64
(random)
Operational
2.3 m/s
2
random, 5 to 2000 Hz, 3 x 1.5 h
Operational,
endurance test
1 g random, 2-100 Hz, 3 x 150 min
Shock
c
IEC
60255-21-2
Operational
Class 2, 30g/11ms, 3 x 6 shocks (half sine)
IEEE 1478
200 m/s
2
, 11 ms, 3 x 6 shocks (saw tooth)
Bump
c
IEC
60255-21-2
Operational
Class 2, 20g/16 rms, 6 x 1000 bumps
Enclosure
EN/IEC/UL
61010-1
Aluminum
Fire enclosure
Weight
690 gr
Degree of protection
EN 60529
Enclosure
IP40
Cooling
Convection
26
Lynx 5500 Series