Environmental
phenomena
Basic
standard
Description
Test levels
Radiated RF
immunity
EN 61000-4-3
IEEE Std
C37.90.2
Enclosure
20 V/m, 80% AM (1kHz) at 80 MHz to 2,7
GHz, spot freq.: 80, 160, 380, 450, 900,
1600, 1850 MHz
10 V/m, 80% AM (1 kHz) at 2.7 to 6 GHz,
spot freq.: 2150, 3800 MHz
20 V/m, pulse keying (2 Hz) at 80 MHz to
1 GHz, spot freq.: 1732, 1800 MHz
10 V/m, pulse keying (2 Hz), spot freq.:
2310, 2450, 5800 MHz
20 V/m, PM 200 Hz square at 900 MHz
Conducted RF
immunity
EN 61000-4-6
DC power port
10 V, 0.15 to 80 MHz, spot freq.: 2, 3, 4,
6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz
Ethernet ports
I/O port
Earth port
Radiated RF emission
CISPR 16-2-3
Enclosure
Class B (Residential), 30 MHz to 6 GHz
DNVGL-CG - Bridge and Deck Zone, 0.15
to 2000 MHz
FCC Part 15 B, Class B, 30 MHz to 20.5
GHz
IEC 60945
ANSI C63,4
Conducted RF
emission
CISPR 16-2-1
DC power port
Class B (Residential), 0.15 to 30 MHz
DNVGL-CG - Bridge and Deck Zone, 10
kHz to 30 MHz
Ethernet ports
Class B (Residential), 0.15 to 30 MHz
Compass safe
distance
IEC 60945
Enclosure
Supply voltage surge
AREMA
DC power port
3 x U
N
, 80 ms (72V)
Power supply failure
DNVGL-
CG-0339
DC power port
U
N
-100%, 30 s
Power supply
variation
DNVGL-
CG-0339
DC power port
1.3 x U
N
(62.4 VDC), 0.75 x U
N
(18
VDC), 15 min
Immunity to
conducted low
frequency
interference
DNVGL-
CG-0339
DC power port
3 Vrms, 0.05 to 10 kHz
Insulation resistance
DNVGL-
CG-0339
Power port (DC)
to all other ports
500 VDC, 60 s
I/O port to all
other ports
IEEE 802.3
Ethernet ports to
all other ports
Dielectric strength
AREMA
Power port (DC)
to all other ports
2121 VDC, 60 s
1500 VAC rms, 60 s
24