5.2. Type Tests and Environmental Conditions
Environmental
phenomena
Basic
standard
Description
Test levels
ESD
EN 61000-4-2
Enclosure
Contact: ±8 kV
Air: ±15 kV
Fast transients
EN 61000-4-4
DC power port
± 2 kV, direct coupling
Earth port
I/O port
± 2 kV, capacitive coupling clamp
Ethernet ports
Surge
EN 61000-4-5
DC power port
L-E: ± 2 kV, 12
Ω
, 9 µF, 1.2/50 µs
L-E: ± 2 kV, 42
Ω
, 0.5 µF, 1.2/50 µs
L-L: ± 0,5 kV, 2
Ω
, 18 µF, 1.2/50 µs
L-L: ± 1 kV, 12
Ω
, 9 µF, 1.2/50 µs
L-L: ± 1 kV, 42
Ω
, 0,5 µF, 1.2/50 µs
I/O port
L-E, L-L: ± 1 kV, 12
Ω
, 9 µF, 1.2/50 µs
L-E, L-L: ±2 kV, 42
Ω
, 0.5 µF, 1.2/50 µs
Ethernet ports
L-E: ± 2 kV, 2
Ω
, Direct on shield,
1.2/50 µs
Power frequency
magnetic field
EN 61000-4-8
Enclosure
300 A/m continues, DC, 16.7 Hz, 50 Hz,
60 Hz
1000 A/m 10 s, 50, 60 Hz
Pulsed magnetic field
EN 61000-4-9
Enclosure
300 A/m
Damped oscillatory
magnetic field
EN 61000-4-10
Enclosure
30 A/m (peak)
Conducted CM
disturbances
EN 61000-4-16
DC power port
30 V rms to 3 V rms, 15 to 150 Hz
3 V rms, 150 Hz to 1.5 kHz
3 V rms to 10 V rms, 1.5 to 15 kHz
30 V rms, 15 to 150 kHz
I/O port
Ethernet ports
Mains frequency
voltage
EN 61000-4-16
DC power port
30 V rms continuous, DC, 16.7, 50 and 60
Hz, 300 V rms for 1 s
I/O port
Ethernet ports
Ripple on DC power
supply
EN 61000-4-17
DC power port
10% of U
N
, 33.3, 100 and 120 Hz, 10 min
Damped oscillatory
wave
EN 61000-4-18
DC power port
CM: ±2.5 kV 200
Ω
/0.5 µF, 1 MHz
CM: ±2 kV 50
Ω
/0.5 µF, 10 MHz
DM: ±2.5 kV 200
Ω
/0.5 µF, 1 MHz
I/O port
CM: ±2.5 kV 200
Ω
/0.5 µF, 1 MHz
DM: ±2.5 kV 200
Ω
/0.5 µF, 1 MHz
Ethernet ports
CM: ±2.5 kV 200
Ω
, 1 MHz, Direct on
shield
Lynx 5500 Series
23