background image

www.westermo.com

         

  

               

                            

OS

Lynx 5500 Series

Industrial Gigabit switch

Содержание 3643-0300

Страница 1: ...www westermo com OS Lynx 5500 Series Industrial Gigabit switch...

Страница 2: ...5 5 FCC Part 15 105 Class B Notice 9 2 5 6 Corrosive Environment 10 2 5 7 Simplified Declaration of Conformity 10 3 Product Description 11 3 1 Product Description 11 3 2 Available Models 11 3 3 Hardw...

Страница 3: ...users of the Westermo products It includes information on safety and regulations a product description installation instructions and technical specifications 1 3 Software Tools Related software tools...

Страница 4: ...zardous situation Possible death or major injury Major damage to the product CAUTION Indicates a potentially hazardous situation Minor or moderate injury Moderate damage to the product NOTICE Provides...

Страница 5: ...nsure a protective earthing conductor is first connected to the protective earthing terminal only valid for metallic housings Westermo recommends a cross sectional area of at least 4 mm2 Upon removal...

Страница 6: ...CFR 1040 10 and 1040 11 HANDLING OF SFP TRANSCEIVERS SFP transceivers are supplied with plugs to avoid contamination inside the optical port They are very sensitive to dust and dirt If the fibre optic...

Страница 7: ...the product and prevent proper operation If the product is used in a manner not according to specification the protection provided by the equipment may be impaired If the product is not working proper...

Страница 8: ...Table 2 Agency approvals and standards compliance 2 5 2 EN IEC UL 61010 2 201 Notice This product has been tested and found compliant to EN IEC UL 61010 2 201 Safety requirements for electrical equip...

Страница 9: ...oduct is specified for long term operation in maximum 70 C 2 5 5 FCC Part 15 105 Class B Notice This product has been tested and found to comply with the limits for a Class B digital device pursuant t...

Страница 10: ...laced in an environment classified as ISA S71 04 class G3 CORROSIVE GASES If the product is placed in a corrosive environment it is important that all unused connector sockets are protected with a sui...

Страница 11: ...ket leading mean time between failure MTBF maximized service life and reduced operational and life cycle costs By providing full gigabit speed on all 12 ports four flexible SFP ports and layer 2 and l...

Страница 12: ...tion No Description 1 Gigabit ports 2 Console port 3 Micro SD 4 Label with QR codea 5 Gigabit SFP Ports 6 Protective earth terminal 7 Power Input and I O connection 8 Warning symbol see warning in Pow...

Страница 13: ...nit condition Status NO C Unpowered pre operational or Alarm active OPEN Operational and Alarm inactive CLOSED Table 7 I O connection status output POWER SUPPLY CONNECTION There are safety regulations...

Страница 14: ...e downloaded from the product support pages at www westermo com support product support In the event of contamination the optical connectors in the SFP transceivers should only be cleaned by the use o...

Страница 15: ...t RSTP USR1 Configurable see WeOS user Guide FRNT OFF FRNT disabled GREEN FRNT OK RED FRNT error BLINK Product configured as FRNT focal point DC1 OFF Product has no power GREEN Power OK on DC1 RED DC1...

Страница 16: ...3 6 Dimensions Dimensions are stated in mm and are regardless model 2 to 8 11 26 100 2 to 8 70 92 DIN surface to front 5 32 108 Figure 6 Dimensional drawing 16 Lynx 5500 Series...

Страница 17: ...port pin 2 Then place the product on to the DIN rail First the upper part then the lower part of the product 3 Lastly push the support pin forward to lock the product to the DIN rail Make sure the pro...

Страница 18: ...support pin Figure 9 Removal of product with screwdriver 4 3 Protective Earth Connection For correct function the earth connection needs to be properly connected to a designated PE rail See the figur...

Страница 19: ...spacing rules Minimum spacing 25 mm 1 0 inch above below and 10 mm 0 4 inches left right the unit Spacing is recommended for the use of unit in full operating temperature range and service life Figur...

Страница 20: ...l current Polarity Reverse polarity protected Redundant power input Yes Isolation All other ports Connector Detachable push in terminal Conductor cross section flexible 0 2 1 5 mm AWG 24 16 Use copper...

Страница 21: ...s Connector Detachable push in terminal Conductor cross section 0 2 1 5 mm AWG 24 16 Use copper conductors only Stripping length cable 10 mm Circuit type SELV Maximum voltage current 60 VDC 80 mA aExt...

Страница 22: ...ceiver supported Console porta Electrical specification USB 2 0 device interface Data rate Up to 480 Mbps high speed mode Circuit type SELV Maximum supply current 100 mA Connector USB Micro B connecto...

Страница 23: ...16 7 Hz 50 Hz 60 Hz 1000 A m 10 s 50 60 Hz Pulsed magnetic field EN 61000 4 9 Enclosure 300 A m Damped oscillatory magnetic field EN 61000 4 10 Enclosure 30 A m peak Conducted CM disturbances EN 6100...

Страница 24: ...one 0 15 to 2000 MHz FCC Part 15 B Class B 30 MHz to 20 5 GHz IEC 60945 ANSI C63 4 Conducted RF emission CISPR 16 2 1 DC power port Class B Residential 0 15 to 30 MHz DNVGL CG Bridge and Deck Zone 10...

Страница 25: ...ll other ports Westermo Power port DC to all other ports 1500 VAC rms 60 s I O port to all other ports IEEE 802 3 Ethernet ports to all other ports Impulse withstand IEEE 802 3 Ethernet ports to all o...

Страница 26: ...ational 5 to 20 Hz 1 3 mm 20 to 200 Hz 1 g 20 sweep cycles in each axis 1 octave min Class 2 10 to 150 Hz at 2 g 20 sweep cycles in each axis 1 octave min 5 to 8 Hz at 7 5 mm 8 to 500 Hz at 2 g 5 swee...

Страница 27: ...N IEC UL 61010 1 Indoor aRefer to Safety and Regulations chapter regarding touch temperature bMethod 3 21 days corresponds to Harsh Industrial Environment G3 which is defined in ANSI ISA 17 04 2015 cT...

Страница 28: ...pdated DC Power port Rev D 2021 06 2 5 1 Agency Approvals and Standards Complience updated 3 2 Available models updated 5 1 Interface Specifications updated Rev C 2021 01 2 5 1 Agency Approvals and St...

Страница 29: ...Westermo Metallverksgatan 6 SE 721 30 V ster s Sweden Tel 46 16 42 80 00 Fax 46 16 42 80 01 E mail info westermo com www westermo com 6643 25001 REV F 2022 01 Westermo Network Technologies AB Sweden...

Отзывы: