23
6641-22810
Earth connection
For correct function, the ground connection on the unit needs to be properly connected
to a solid ground. See the figure below.
Status-
Digital In-
Digital In+
Protective earth
Cooling
This unit uses convection cooling. To avoid obstructing the airflow around the unit,
follow the spacing recommendations (see Cooling section). For mounting in 19"
apparatus cabinet without forced ventilation, a minimal spacing of 1U according to IEC
60297 or 45 mm (1.75") above/below is recommended. With forced ventilation, no
minimal spacing is required as long as the temperature of the rear cooling plates does
not 85
º
C (+185
º
F).
For wallmounting in an area without forced ventilation, a minimum spacing of 45 mm
(1.75") above/below and 10 mm (0.4") left/right is recommended. For areas with forced
ventilation, no minimal spacing is required as long as the temperature of the rear cooling
plates does not 85
º
C (+185
º
F).